• 제목/요약/키워드: exchange spring effect

검색결과 15건 처리시간 0.026초

Exchange Coupling in NiFe/Ni Bilayer Fabricated By Electrodeposition

  • Kim, D.Y.;Jeon, S.J.;Kim, K.W.;Yoon, S.S.
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.97-100
    • /
    • 2011
  • Bilayers of soft NiFe (150 nm-420 nm) on hard Ni (150 nm) were prepared by electrodeposition. The process of magnetization reversal in the NiFe/Ni bilayers was then investigated. The hysteresis loop generated by a magnetization reversal of soft NiFe under a positive saturation state of a hard Ni layer shows a shift along the negative field axis, which is clear evidence for the exchange spring effect in the NiFe/Ni bilayers. The dependence of the coercive field $H_c$ and exchange bias field Hex on the thickness of the NiFe layer was also investigated. As the NiFe thickness increases from 150 nm to 420 nm, both $H_c$ and $H_{ex}$ decrease rapidly from $H_c$= 51.7 Oe and $H_{ex}$ = 12.2 Oe, and saturate to $H_c$ = 5.8 Oe and $H_{ex}$ = 3.5 Oe.

해수교환 방파제 설치에 따른 수질개선효과 (Effect of Water Quality Improvement by Seawater Exchange Breakwater Install)

  • 한동준;이달수
    • 환경위생공학
    • /
    • 제21권3호
    • /
    • pp.61-72
    • /
    • 2006
  • This study was carried out for verification of efficiency of seawater exchange breakwater which was installed in joomoongin harbor for the first time in our country. The joomoongin harbor, where seawater exchange breakwater has been constructed, shows typical for fishery and tourist port city specifics of greatest pollutants discharge volume in spring and summer, when tourist inflow and fishery activity is most vigorous. On the East Sea seawater flux through seawater exchange breakwater for the smallest waves (up to 0.5 m) was found out to be $1,526-3,052m^3/day$. After construction of seawater exchange breakwater, Zone 1 and Zone 2 of stagnant water inside the port were found to be a lot improved. Zone 3, adjacent to outport area, was found to be lower comparing with Zone 1 and Zone 2. The results of statistical analysis show that comparing with water quality improvement effect before and after seawater exchange, water quality after installation of seawater exchange breakwater became much better, primarily because of physical change around the harbour.

Enhanced Exchange Coupling of $Nd_2Fe_{14}B/Fe_3B$ Magnet Via Magnetic Field Treatment

  • Choong Jin Yang;Con Byung Park
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.31-36
    • /
    • 1996
  • An externally applied magnetic field during heat treating the $Nd_2Fe_{14}B/Fe_3B$ based spring magnet was found to enhance the exchange coupling between the hard and soft magnetic grains. More than 30% increase in $M_r/M_s$ values for melt-spun $Nd_2Fe_{73.5}Co_3$$(Hf_{1-x}Ga_x)B_{18.5}$ (x=0, 0.5, 1) alloys was resulted from a uniform distribution of $Fe_3B, \alpha-Fe$ and $Nd_2Fe_{14}B$ phases, and also from a reduced grain size of those phases by 20%. The externally applied magnetic field induced a uniform distribution of fine grains. A study of Mossbauer effect also report that the enhancement of total magnetization of nanocomposite $Nd_2Fe_{14}B/Fe_3B$ alloys is attributed to an increased formation of $Fe_3$B after magnetic annealing.

  • PDF

자장중 열처리에 의한 $Nd_{2}Fe_{14}B/Fe_{3}B$ 초미세립 복합자성상의 자기특성 향상 (The Effect of Magnetic Field Treatment on Enhanced Exchange Coupling of $Nd_{2}Fe_{14}B/Fe_{3}B$ Magnet)

  • 박언병;양충진
    • 한국자기학회지
    • /
    • 제6권2호
    • /
    • pp.80-85
    • /
    • 1996
  • $Nd_{2}Fe_{14}B/Fe_{3}B$ 복합자성상을 근간으로 한 급냉제조된 합금을 외부 자장중에서 열처리를 함으로써 자기특성이 월등하게 좋아짐을 확인하였다. $Nd_{4}Fe_{73.5}Co_{3}(Hf_{1-x}-Ga_{x})B_{18.5}$ 조성 합금을 1~5 kOe 자장중에서 열처리함으로써 연자성의 기지상$(Fe_{3}B)$ 및 강자성상$(Nd_{2}Fe_{14}B)$의 결정입도가 20% 감소하였고, 그 결과 잔류자속밀도 $(B_{r})$ 및 최대자기에너지적, ${(B.H)}_{max}$가 30% 이상 증가하였다. 이러한 증가는 입도의 감소 뿐만 아니라 미세입도의 고른 분포에도 기인한 것으로 판단되었다. 보자력의 극대점은 잔류자속밀도와는 달리 특정결정입도에서 발생하며, 이러한 기구를 교환상호작용변수 와 연관하여 설명한다. $Nd_{4}Fe_{73.5}Co_{3}Hf_{0.5}Ga_{0.5}B_{18.5}$ 합금을 자장중 열처리한 결과 ${(B.H)}_{max}=15.8$ MGOe의 고에너지적을 얻을 수 있음을 확인하였다.

  • PDF

기후변동성에 따른 육상 탄소 순환의 반응 (Response of the Terrestrial Carbon Exchange to the Climate Variability)

  • 선민아;조천호;김영미;이조한;부경온;변영화
    • 대기
    • /
    • 제27권2호
    • /
    • pp.163-175
    • /
    • 2017
  • The global terrestrial ecosystems have shown a large spatial variability in recent decades and represented a carbon sink pattern at mid-to-high latitude in Northern Hemisphere. However, there are many uncertainties in magnitude and spatial distribution of terrestrial carbon fluxes due to the effect of climate factors. So, it needs to accurately understand the spatio-temporal variations on carbon exchange flux with climate. This study focused on the effects of climate factors, .i.e. temperature, precipitation, and solar radiation, to terrestrial biosphere carbon flux. We used the terrestrial carbon flux that is simulated by a CarbonTracker, which performs data assimilation of global atmospheric $CO_2$ mole fraction measurements. We demonstrated significant interactions between Net Ecosystem Production (NEP) and climate factors by using the partial correlation analysis. NEP showed positive correlation with temperature at mid-to-high latitude in Northern Hemisphere but showed negative correlation pattern at $0-30^{\circ}N$. Also, NEP represented mostly negative correlation with precipitation at $60^{\circ}S-30^{\circ}N$. Solar radiation affected NEP positively at all latitudes and percentage of positive correlation at tropical regions was relatively lower than other latitudes. Spring and summer warming had potentially positive effect on NEP in Northern Hemisphere. On the other hand as increasing the temperature in autumn, NEP was largely reduced in most northern terrestrial ecosystems. The NEP variability that depends on climate factors also differently represented with the type of vegetation. Especially in crop regions, land carbon sinks had positive correlation with temperature but showed negative correlation with precipitation.

Economizer cycle을 채용한 전열교환형 환기시스템의 에너지 절감 효과 분석 -국내 학교를 대상으로- (Energy Saving Effect of ERV(Energy Recovery Ventilator) with Economizer Cycle - Focused on the School Buildings -)

  • 김주욱;박재형;송두삼;주의성;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.695-700
    • /
    • 2009
  • Maintaining an IAQ with fresh in school building is very important because the good IAQ can be possible to improve the academic performance. Since school buildings are very dense and require a lot of fresh air, the need for ERV(Energy Recovery Ventilator) has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency. ERV technology offers an optimal solution: fresh air, better climate control and energy efficiency. However, when the outdoor air condition is favorable to control the indoor environment such as spring and autum in Korea, heat exchange in ERV would rather increase the cooling load than diminish. Economizer cycle control which using the outdoor air in controlling the indoor thermal environment has many benefit in terms of energy saving and IAQ control. In this study, the ERV with economizer cycle control will be suggested. And then the system control characteristics and energy saving effect will be analyzed through the TRSNSYS Simulation.

  • PDF

시화호 수질 악화에 따른 시화호와 주변 해역 어류의 종조성 변화 (Changes of Species Composition of Fish in Polluted Lake Shihwa and Adjacent Coastal Area)

  • 이태원;문형태;허성회
    • 한국해양학회지:바다
    • /
    • 제2권2호
    • /
    • pp.110-116
    • /
    • 1997
  • 시화호가 건설 된 후인 1995년 10월에서 1996년 8월 사이 시화호 내부와 외부에서 계절 별로 어류를 채집하여, 출현종의 조성 변화를 분석하고 내부의 수질이 어류에 미치는 영향을 고찰하였다. 호수 외부에서는 청어목 어류 및 참서대와 민태가 우점하여 인접 해역과 유사한 경향을 보였다. 호수 내에서는 가을에 연안성 부어류, 망둑어류 및 민불어류인 붕어가 채집되었으나, 겨울이 지난 후 외해에서 월동하여야 하는 부어류들은 채집되지 않았고, 망둑어류와 붕어도 숫적으로 감소하였다. 봄이 되어 소수 풀망둑을 제외한 어류는 채집되지 않았고, 여름에는 해수와 호수물 교환 과정에서 들어 온 두둘망둑과 구굴무치가 대량 출현하였으나 8월 중순 폐사하였다. 1996년 3월 이후 암모늄 농도는 다른 어류에서 관찰된 반치사농도보다 높았으며, 수온과 pH의 상승으로 암모니아의 어류에 대한 독성이 강하여지고 다른 요인들과 복합적으로 작용하여 어류들이 폐사한 것으로 보인다.

  • PDF

Hysteresis Loops, Critical Fields and Energy Products for Exchange-spring Hard/soft/hard Trilayers

  • Chen, B.Z.;Yan, S.;Ju, Y.Z.;Zhao, G.P.;Zhang, X.C.;Yue, M.;Xia, J.
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.31-39
    • /
    • 2015
  • Macroscopic hysteresis loops and microscopic magnetic moment distributions have been determined by a three-dimensional (3D) model for exchange-coupled Sm-Co/${\alpha}-Fe$/Sm-Co trilayers with in-plane collinear easy axes. These results are carefully compared with the popular one-dimensional (1D) micromagnetic models and recent experimental data. It is found that the results obtained from the two methods match very well, especially for the remanence and coercivity, justifying the calculations. Both nucleation and coercive fields decrease monotonically as the soft layer thickness $L^s$ increases while the largest maximum energy product (roughly 50 MGOe) occurs when the thicknesses of hard and soft layers are 5 nm and 15 nm, respectively. Moreover, the calculated angular distributions in the thickness direction for the magnetic moments are similar. Nevertheless, the calculated nucleation and pinning fields as well as the energy products by 3D OOMMF are systematically smaller than those given by the 1D model, due mainly to the stray fields at the corners of the films. These demagnetization fields help the magnetic moments at the corners to deviate from the previous saturation state and facilitate the nucleation. Such an effect enhances as $L^s$ increases. When the thicknesses of hard and soft layers are 10 nm and 20 nm, respectively, the pinning field difference is as large as 30%, while the nucleation fields have opposite signs.

마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구 (A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay)

  • 김권수;유하상;김강민
    • 한국항해항만학회지
    • /
    • 제37권6호
    • /
    • pp.637-645
    • /
    • 2013
  • 마산만은 반폐쇄성 해역으로, 느린 유속과 육상오염물질의 하천부하 등으로 인해 심각한 수질문제를 가지고 있으며, 동시에 폭풍해일에 취약한 입지적 특성을 나타내고 있다. 이 중 폭풍해일 저감대책으로 제시된 재해방지시설을 운용함과 동시에 이를 마산만 내측 수질개선에 활용하는 방안을 모색하였다. 즉, 재해방지시설을 가동하여 마산만 내측과 외측의 수위조건이 다를 때 발생하는 수두차를 이용하여 만 내 외의 해수를 교환하였다. 재해방지시설의 위치를 기존 만 입구부, 마창대교 인근, 그리고 돝섬 인근으로 가정하였으며, 선박운항 횟수와 연간조위를 분석하여 통항빈도가 가장 낮은 새벽시간(01~05) 및 수두차가 가장 큰 대조기에 운용된다고 가정하였다. 또한, 재해방지시설과 함께 약 10km 길이의 유출 입 관로를 통한 내 외해수의 해수교환 촉진을 위한 추가 실험안을 구성하였다. 수치모의 결과, 현재상태의 경우 마산만 전체 해수교환율은 38.62%을 나타냈으며, 모든 실험안에서 마산만 내 모든 구역에서 꾸준한 증가 추세를 보이고 있다. 이에 반해, 마산만 입구부와 비교한 마산만 내측의 해수교환율은 매우 낮게 나타나 반폐쇄성 내만해역의 특성을 잘 재현하는 것으로 판단된다. 재해방지시설과 관로를 이용한 실험안을 분석한 결과, 현재상태와 비교하여 재해방지시설을 운용한 경우 해수교환율이 높고, 그 운용빈도가 많아질수록 더 많은 순환이 이루어지는 것으로 나타났다. 또한, 재해방지시설에 의해 발생된 수두차를 이용하여 관로를 통해 해수를 유입 혹은 유출한 경우 마산만 가장 내측의 수질이 개선되는 것으로 나타났다. 재해방지시설의 위치는 마창대교 남측과 비교하여 마산만 입구와 돝섬에 위치한 경우 해수교환 효과가 더 좋게 나타났다. 한편 마산만 전체영역에 대한 해수교환율은 만 입구에 재해방지시설이 위치한 경우가 돝섬에 위치한 경우보다 높지만, 마산만 내측을 포함한 해수교환율은 반대로 돝섬에 위치한 경우가 더 높게 나타났다.

아파트의 겨울철 실내온열환경 실태와 생활요인 분석 (Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter)

  • 최윤정;정연홍
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF