• Title/Summary/Keyword: exchange spring effect

Search Result 15, Processing Time 0.023 seconds

Exchange Coupling in NiFe/Ni Bilayer Fabricated By Electrodeposition

  • Kim, D.Y.;Jeon, S.J.;Kim, K.W.;Yoon, S.S.
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.97-100
    • /
    • 2011
  • Bilayers of soft NiFe (150 nm-420 nm) on hard Ni (150 nm) were prepared by electrodeposition. The process of magnetization reversal in the NiFe/Ni bilayers was then investigated. The hysteresis loop generated by a magnetization reversal of soft NiFe under a positive saturation state of a hard Ni layer shows a shift along the negative field axis, which is clear evidence for the exchange spring effect in the NiFe/Ni bilayers. The dependence of the coercive field $H_c$ and exchange bias field Hex on the thickness of the NiFe layer was also investigated. As the NiFe thickness increases from 150 nm to 420 nm, both $H_c$ and $H_{ex}$ decrease rapidly from $H_c$= 51.7 Oe and $H_{ex}$ = 12.2 Oe, and saturate to $H_c$ = 5.8 Oe and $H_{ex}$ = 3.5 Oe.

Effect of Water Quality Improvement by Seawater Exchange Breakwater Install (해수교환 방파제 설치에 따른 수질개선효과)

  • Han, Dong-Joon;Lee, Dal-Soo
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.3 s.61
    • /
    • pp.61-72
    • /
    • 2006
  • This study was carried out for verification of efficiency of seawater exchange breakwater which was installed in joomoongin harbor for the first time in our country. The joomoongin harbor, where seawater exchange breakwater has been constructed, shows typical for fishery and tourist port city specifics of greatest pollutants discharge volume in spring and summer, when tourist inflow and fishery activity is most vigorous. On the East Sea seawater flux through seawater exchange breakwater for the smallest waves (up to 0.5 m) was found out to be $1,526-3,052m^3/day$. After construction of seawater exchange breakwater, Zone 1 and Zone 2 of stagnant water inside the port were found to be a lot improved. Zone 3, adjacent to outport area, was found to be lower comparing with Zone 1 and Zone 2. The results of statistical analysis show that comparing with water quality improvement effect before and after seawater exchange, water quality after installation of seawater exchange breakwater became much better, primarily because of physical change around the harbour.

Enhanced Exchange Coupling of $Nd_2Fe_{14}B/Fe_3B$ Magnet Via Magnetic Field Treatment

  • Choong Jin Yang;Con Byung Park
    • Journal of Magnetics
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 1996
  • An externally applied magnetic field during heat treating the $Nd_2Fe_{14}B/Fe_3B$ based spring magnet was found to enhance the exchange coupling between the hard and soft magnetic grains. More than 30% increase in $M_r/M_s$ values for melt-spun $Nd_2Fe_{73.5}Co_3$$(Hf_{1-x}Ga_x)B_{18.5}$ (x=0, 0.5, 1) alloys was resulted from a uniform distribution of $Fe_3B, \alpha-Fe$ and $Nd_2Fe_{14}B$ phases, and also from a reduced grain size of those phases by 20%. The externally applied magnetic field induced a uniform distribution of fine grains. A study of Mossbauer effect also report that the enhancement of total magnetization of nanocomposite $Nd_2Fe_{14}B/Fe_3B$ alloys is attributed to an increased formation of $Fe_3$B after magnetic annealing.

  • PDF

The Effect of Magnetic Field Treatment on Enhanced Exchange Coupling of $Nd_{2}Fe_{14}B/Fe_{3}B$ Magnet (자장중 열처리에 의한 $Nd_{2}Fe_{14}B/Fe_{3}B$ 초미세립 복합자성상의 자기특성 향상)

  • 박언병;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.80-85
    • /
    • 1996
  • An externally applied magnetic field during annealing the $Nd_{2}Fe_{14}B/Fe_{3}B$ based spring magnet was found to enhance the exchange coupling between the hard and soft magnetic grains. More than 30 % increase in remanence values for melt-spun $Nd_{4}Fe_{73.5}Co_{3}(Hf_{1-x}-Ga_{x})B_{18.5}$(x=0, 0.5, 1.0) alloys was resulted from uniform distribution of $Fe_{3}B$, $\alpha$-Fe as well as $(Nd_{2}Fe_{14}B)$, and also from reduced grain size of those phases by 20 %. The result also showed that there is an optimum grain size exhibiting a high coercivity value which will be discussed in terms of previously simulated exchange coupling parameter.

  • PDF

Response of the Terrestrial Carbon Exchange to the Climate Variability (기후변동성에 따른 육상 탄소 순환의 반응)

  • Sun, Minah;Cho, Chun-Ho;Kim, Youngmi;Lee, Johan;Boo, Kyoung-On;Byun, Young-Hwa
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.163-175
    • /
    • 2017
  • The global terrestrial ecosystems have shown a large spatial variability in recent decades and represented a carbon sink pattern at mid-to-high latitude in Northern Hemisphere. However, there are many uncertainties in magnitude and spatial distribution of terrestrial carbon fluxes due to the effect of climate factors. So, it needs to accurately understand the spatio-temporal variations on carbon exchange flux with climate. This study focused on the effects of climate factors, .i.e. temperature, precipitation, and solar radiation, to terrestrial biosphere carbon flux. We used the terrestrial carbon flux that is simulated by a CarbonTracker, which performs data assimilation of global atmospheric $CO_2$ mole fraction measurements. We demonstrated significant interactions between Net Ecosystem Production (NEP) and climate factors by using the partial correlation analysis. NEP showed positive correlation with temperature at mid-to-high latitude in Northern Hemisphere but showed negative correlation pattern at $0-30^{\circ}N$. Also, NEP represented mostly negative correlation with precipitation at $60^{\circ}S-30^{\circ}N$. Solar radiation affected NEP positively at all latitudes and percentage of positive correlation at tropical regions was relatively lower than other latitudes. Spring and summer warming had potentially positive effect on NEP in Northern Hemisphere. On the other hand as increasing the temperature in autumn, NEP was largely reduced in most northern terrestrial ecosystems. The NEP variability that depends on climate factors also differently represented with the type of vegetation. Especially in crop regions, land carbon sinks had positive correlation with temperature but showed negative correlation with precipitation.

Energy Saving Effect of ERV(Energy Recovery Ventilator) with Economizer Cycle - Focused on the School Buildings - (Economizer cycle을 채용한 전열교환형 환기시스템의 에너지 절감 효과 분석 -국내 학교를 대상으로-)

  • Kim, Joo-Wook;Park, Jae-Hyung;Song, Doo-Sam;Chu, Euy-Sung;Kwon, Young-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.695-700
    • /
    • 2009
  • Maintaining an IAQ with fresh in school building is very important because the good IAQ can be possible to improve the academic performance. Since school buildings are very dense and require a lot of fresh air, the need for ERV(Energy Recovery Ventilator) has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency. ERV technology offers an optimal solution: fresh air, better climate control and energy efficiency. However, when the outdoor air condition is favorable to control the indoor environment such as spring and autum in Korea, heat exchange in ERV would rather increase the cooling load than diminish. Economizer cycle control which using the outdoor air in controlling the indoor thermal environment has many benefit in terms of energy saving and IAQ control. In this study, the ERV with economizer cycle control will be suggested. And then the system control characteristics and energy saving effect will be analyzed through the TRSNSYS Simulation.

  • PDF

Changes of Species Composition of Fish in Polluted Lake Shihwa and Adjacent Coastal Area (시화호 수질 악화에 따른 시화호와 주변 해역 어류의 종조성 변화)

  • Lee, Tae-Won;Moon, Hyung-Tae;Huh, Sung-Hoi
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.110-116
    • /
    • 1997
  • Changes of fish species composition were analyzed using seasonal samples collected from Lake Shihwa and adjacent coastal water from October 1995 to August 1996. Pelagic clupeids, Cynoglossus joyneri and Johnius belengerii predominated in abundance in the adjacent coastal water. In the lake, clupeids, gobies and freshwater Carassius carassius were collected in autumn. The clupeids, unable to overwinter in the open water, disappeared after winter. The gobies and C. carassius were also disappeared in spring except a few number of Acanthogobius hasta. A large number of Tridentiger trigonocephalus and Eleotris oxycephala were collected in summer, supposed to move into the lake during the exchange of water in lake and sea water. However, they were all died in the middle of August. The concentration of ammonium-nitrogen was higher than 2 mg/l, which was higher than 50% lethal concentraton in other fishes. Increase in temperature and pH in spring may elevate the toxicity of ammonium to fish. We discussed the effect of the other factors of the polluted water in the lake on the disappearance of fish.

  • PDF

Hysteresis Loops, Critical Fields and Energy Products for Exchange-spring Hard/soft/hard Trilayers

  • Chen, B.Z.;Yan, S.;Ju, Y.Z.;Zhao, G.P.;Zhang, X.C.;Yue, M.;Xia, J.
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Macroscopic hysteresis loops and microscopic magnetic moment distributions have been determined by a three-dimensional (3D) model for exchange-coupled Sm-Co/${\alpha}-Fe$/Sm-Co trilayers with in-plane collinear easy axes. These results are carefully compared with the popular one-dimensional (1D) micromagnetic models and recent experimental data. It is found that the results obtained from the two methods match very well, especially for the remanence and coercivity, justifying the calculations. Both nucleation and coercive fields decrease monotonically as the soft layer thickness $L^s$ increases while the largest maximum energy product (roughly 50 MGOe) occurs when the thicknesses of hard and soft layers are 5 nm and 15 nm, respectively. Moreover, the calculated angular distributions in the thickness direction for the magnetic moments are similar. Nevertheless, the calculated nucleation and pinning fields as well as the energy products by 3D OOMMF are systematically smaller than those given by the 1D model, due mainly to the stray fields at the corners of the films. These demagnetization fields help the magnetic moments at the corners to deviate from the previous saturation state and facilitate the nucleation. Such an effect enhances as $L^s$ increases. When the thicknesses of hard and soft layers are 10 nm and 20 nm, respectively, the pinning field difference is as large as 30%, while the nucleation fields have opposite signs.

A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay (마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구)

  • Kim, Gweon-Su;Ryu, Ha-Sang;Kim, Kang-Min
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.637-645
    • /
    • 2013
  • Masan bay with a semi-enclosed waters has serious water quality problems due to the low flow and river pollution load from land, and shows the vulnerable locational characteristics to storm surge. We are seeking the way of both operating disaster prevention facilities and water quality improvement measures in the bay. That is, the water was exchanged using the head difference occurred by operating disaster prevention facilities. The location of disaster prevention facilities was assumed to be in the inlet of the bay, in the vicinity of Machang bridge, and in the vicinity of Dot island and the operation time was assumed to be early morning hours(01~05) considering the number of shipping passage and annual tide, and spring tide of the largest head difference. In addition, the experiment case of water exchange including the in-outflow feeder pipe was tested. According to the simulation results, water exchange rate in all experiments has shown a steady increase. Water exchange rate of the whole of Masan bay in the case of present is 38.62%. The water exchange rate of the inside of Masan bay compared with the inlet of bay, appeared to be very low. Thus, we judged that the characteristics of semi-enclosed waters were well reproduced. On the results of the experiment of disaster prevention facilities and in-outflow feeder pipe, the case of the operation of disaster prevention facilities, water exchage rate is high compared with the case of present. And, the higer the operating frequency, the more water exchange is appeared. The cases of water exchange prevention facilities through the in-outflow feeder pipe caused by the head difference, also showed the higest improvement of the water quality. Compared with the south of Machang bridge, the effect of water exchange was better in the inlet of Masan bay and Dot island. On the other hand, the inlet of Masan bay is higer than Dot island as for water exchange of the whole of Masan bay, but opposite, water change rate including Masan inside was higher in the case of Dot island.

Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF