• Title/Summary/Keyword: excessive water

Search Result 728, Processing Time 0.031 seconds

Effect of Forced Oral Administration of Excessive Tap water on the Water Content and Histological Changes of Some Muscles of Korean Cattle (강제급수(强制給水)가 우근육(牛筋肉)의 함수율(含水率)과 조직학적성상(組織學的性狀)에 미치는 영향(影響))

  • Choi, H.I.;Hong, B.W.
    • Korean Journal of Veterinary Research
    • /
    • v.12 no.1
    • /
    • pp.127-132
    • /
    • 1972
  • Experimental studies on the water content of muscles and the histological changes of muscles, digestive tract and kidney, influenced by forced oral administration of excessive tap water, were performed by using 10 Korean bulls. Experimental animals were divided into two groups, five heads for test group and five for control group. All of the bulls used in this experiment were weighing between 250 kg and 300 kg and 3 and 4 years of age. In each test animal, a total of 140 litters of tap water was passed in the forestomach by means of catheterization within 12 to 18 hours. And each of them was slaughtered immediately after the animals showing symptoms of respiratory distress. In control group, the animals were allowed to drink tap water normally. From test and control animals after slaughter, each 10 gm of M. biceps femoris, M. satorius, M. adductor, M. gluteous supercialis, M. iliocostalis lumborum, and M. transversus costarum were taken from definite parts in order to measure water content. In the histopathological studies tissues of rumen, reticulum, omasum, abomasum, duodenum, colon and kidney were taken as wall as the above mentioned muscles. The results obtained were as follows; 1. Increase of water content in the muscles of test group were 4.6% in M. satorius, 4.24% in M. transversus costarum, 4.14% in M. gluteous supercialis, 4.02% in M. adductor, 3.88% in M. biceps femoris, and 2.46% in M. iliocostalis lumborum respectively. The highest increase was found in M. satorius and the lowest in M. iliocostalis lumborum. 2. In test animal, average increasing value of water content in muscles was 3.9% and shown highly significant (p<0.01). 3. On the microscopical findings of carcass, marked watery edema was observed all of the subcutaneous tissues and intermuscular connective tissues. 4. Microscopically, the epimysium, perimysium and endomysium were widened, and the muscle fibers were lacerated. The cells of stratum lucidum in the epithelium of rumen and reticulum were shown marked vacuolization. In the kidney, dilatation of Bowman's spaces and proximal tubles was observed.

  • PDF

Effects of Soil Moisture Content on Leaf Water Potential and Photosynthesis in Soybean Plants (토양성분이 콩의 잎 수분포텐셜 및 광합성에 미치는 영향)

  • 류용환;이석하;김석동
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.2
    • /
    • pp.168-172
    • /
    • 1996
  • The soil moisture content and its relation to plants may be important in determining the crop growth and yield. The present study was undertaken to evaluate the leaf water potential and photosynthetic activity in soybean plants as affected by the timing of soil water stress. The soybean variety, 'Tachinagaha', was grown in a pot. The 15 day-old seedlings were subject to the three levels of soil moisture content(25, 40 and 55%) for 25 days. Then the treated soybean plants were placed again at the level of 25% soil moisture content for 25 days, and were compared with the control which was well-watered at 40% level for whole growth period. Soybean plants grown under continuous drought showed higher apparent photosynthetic rate(AP) than those under well-watering /drought in the first /second water treatment, suggesting that AP was adjusted after previous acclimation to drought. Over a wide range of photosynthetic photon flux densities(PPFD), drought or excessive water stress resulted in the decrease in AP when compared with the control. AP and stomatal conductance were decreased in soybean plants subject to water deficit stress, suggesting that AP and stomatal conductance were more sensitive to drought than excessive water stress.

  • PDF

Pollutant concentrations in Experimental Paddy Plots with Different Fertilizer Application Rates (시비조건의 차이에 따른 시험군 논에서의 오염물질의 농도)

  • Cho, Jae-Won;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.473-476
    • /
    • 2002
  • The effect of fertiltzer application on ponded and percolation water in rice paddy were investigated at the experimental plots during irrigation period. We laid out three experimental plots such as 150% Excessive, 100% Standard and 70% Reduced. The concentration of T-N and T-P in ponded water were increased rapidly after application. The concentration of T-N and COD in percolated water increased with fertilizer application rates, while T-P concentration were almost constant.

  • PDF

Optimal Ballasting in the Preliminary Ship Design Stage (초기설계 단계에서의 최적 발라스트 용량에 관한 연구)

  • Gang, Won-Su
    • 한국기계연구소 소보
    • /
    • s.15
    • /
    • pp.117-125
    • /
    • 1985
  • It is usual practice to ballast a sip to maintain requires operational safety at sea. However, excessive ballasting may reduce the operational economy of a ship. Therefore, The determination of the optimal location and quantity of ballast water is one of the important works at the preliminary design stage. To provide a convenient tool to ship designers the program for the determination of the optimal location and program the effect of the change of ballast water quantity in each tank on some characteristics of a ship, such as trim, initial stability and heel, is investigated and the minimum quantity of ballast water for each tank which satisfies the operational safety requirements is calculated.

  • PDF

An analysis of water hammer in pipeline systems with pump (펌프관로계의 수격현상 해석)

  • 이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.92-99
    • /
    • 1998
  • Unsteady flow problems created by hydraulic transients in pipeline systems with pump are of significant importance because they can cause excessive pressure, cavitation, vibration and noise. In this paper, an analysis of transient flow for the pump pipelines is developed by means of the characteristic method. The calculated results of the program to simulate water hammer due to sudden valve closure in a simple pipeline are compared with those of the analytical method. Expecially the water hammer due to power failure in pump pipeline system with surge tank was simulated. As the results, both the upsurge and the downsurge along the pipeline are reduced.

  • PDF

Pollutant Concentrations at Experimental Paddy Plots during Irrigation Season (관개기 시험구 논에서의 오염물질의 농도특성)

  • Cho, Jae-Won;Kim, Jin-Soo;Oh, Kwang-Young;Oh, Seung-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.3
    • /
    • pp.97-106
    • /
    • 2006
  • The pollutant concentrations at experimental paddy plots with three (excessive, standard, reduced) different fertilization rates were investigated during 2001-2002 irrigation seasons. Mean concentrations of pollutants in ponded water were not significantly different among three experimental plots, but the T-N concentrations in percolated water significantly depended on fertilization rates. The T-N, T-P and $COD_{Cr}$, concentrations in ponded water during early irrigation season (late May to mid-June) were much higher than those during later irrigation season likely due to fertilization and low uptake by young rice crops. The T-N concentrations decreased but the concentrations of T-P and $COD_{Cr}$, increased three days after tillering fertilization. The removal rates of T-N by paddy plots were $0.13-0.16g/m^2{\cdot}d$ for an excessive fertilization plot, $0.08-0.25g/m^2{\cdot}d$ for a standard fertilization plot, and $0.03-0.34g/m^2{\cdot}d$ for a reduced fertilization plot three days after tillering fertilization. On the other hand, T-P and $COD_{Cr}$, were released three days after tillering fertilization.

Analytical and Experimental Study on Vibration Characteristics for Rectangular Tank Structure Filled with Fluid (사각헝 탱크 구조의 접수 진동 특성에 관한 연구)

  • 최수현;김극수;손성완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.195-203
    • /
    • 2002
  • In the engine room and the aft part areas of the ship, there exist so many tank structures contacting with fresh water or sea water or oil. If these structures exhibit excessive vibrations during the sea trials, it takes a lot of cost, time and effort to improve vibration situation because the reinforcement work requires emptying the fluid out of the tanks, additional welding and special painting. It is therefore very important to predict a precise vibration characteristics of the tank structures at the design stage, however it is not easy to estimate vibration characteristics of the structures because of difficulties for accurate evaluation of the added (or virtual) mass effect due to the fluid inside the tank. In this paper, numerical and experimental approaches have been performed to present same fundamental data necessary for anti-vibration design of tank structures contacting with fluid, by investigating vibration behaviors of rectangular tank structure for various water depths.

Analysis on Rainwater Harvesting System as a Source of Non-Potable Water for Flood Mitigation in Metro Manila (마닐라의 홍수저감을 위한 잡용수 대체자원으로서의 가정용우수저류시설 분석)

  • Necesito, Imee V.;Felix, Micah Lourdes A.;Kim, Lee-Hyung;Cheong, Tae Sung;Jeong, Sangman
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 2013
  • Excessive precipitation, drought, heat waves, strong typhoons and rising sea levels are just some of the common indicators of climate change. In the Philippines, excessive precipitation never failed to devastate and drown the streets of Metro Manila, a highly urbanized and flood-prone area; such problems are expected to occur frequently. Moreover, the water supply of Metro Manila is dependent only to Angat Reservoir. Rainwater harvesting can serve as an alternative source of raw water and it can mitigate the effects of flooding. The harvested rainwater can be used for: potable consumption if filtered and disinfected; and non-potable consumptions (e.g., irrigation, flushing toilets, carwash, gardening, etc.) if used untreated. The rainfall data were gathered from all 5 rainfall stations located in Metro Manila namely: Science Garden, Port Area, Polo, Nangka and Napindan rain gauge stations. To be able to determine the potential volume of rainwater harvested and the potentiality of rainwater harvesting system as an alternate source of raw water; in this study, three different climatic conditions were considered, the dry, median and wet rainfall years. The frequent occurrence of cyclonic events in the Philippines brought significant amount of rainwater that causes flooding in the highly urbanized region of Metro Manila. Based from the results of this study, the utilization of rainwater harvesting system can serve as an alternative source of non-potable water for the community; and could also reduce the amount of surface runoff that could result to extreme flooding.

A Plan on the Flood Control Ability Improvement Project to maintain stability of existing dams (기존댐 치수능력 증대사업의 시행 방안)

  • Lee, Wan-Ho;Ahn, Hee-Bok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.191-201
    • /
    • 2006
  • The flood control ability improvement project on existing dams is the project for prevention of disasters from excessive flood due to climate changes and thus protects lives and property damages by increasing safety of dams. The collapse of dam brings unimaginable disasters, so the project needs to be swiftly conducted by Government's funding. This paper introduces tile examples of the flood control ability improvement projects of multi-purpose and water supply dams, which is conducted in the way of structural measures among 26 dams operated by Kwater.

  • PDF

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.