• Title/Summary/Keyword: excess energy

Search Result 522, Processing Time 0.025 seconds

A Study on Deficiency Syndrome, Excess Syndrome, Reinforcing Method and Reducing Method (허실보사(虛實補瀉)에 대한 문헌적(文獻的) 고찰(考察))

  • Yang, Kwang-Yeol
    • The Journal of Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.200-206
    • /
    • 2008
  • Objective : To establish a standard for discriminating between deficiency syndrome and excess syndrome and selecting reinforcing or reducing method. Methods :Deficiency syndrome and excess syndrome were divided into excess of pathogenic factor with sufficiency of vital energy syndrome, weakness of pathogenic factor with deficiency of vital energy syndrome and excess of pathogenic factor with deficiency of vital energy syndrome. Documentary survey was done for each case. Results : Excess of pathogenic factor with sufficiency of vital energy syndrome is an excess syndrome and a reducing method must be used. Weakness of pathogenic factor with deficiency of vital energy syndrome is a deficiency syndrome and a reinforcing method must be used. Excess of pathogenic factor with deficiency of vital energy syndrome is related to deficiency syndrome and a reinforcing method must mainly be used. Conclusions :Deficiency or sufficiency of vital energy is the standard for discriminating between deficiency syndrome and excess syndrome and selecting a reinforcing or reducing method.

  • PDF

Examination of excess electricity generation patterns in South Korea under the renewable initiative for 2030

  • Kim, Philseo;Cho, So-Bin;Yim, Man-Sung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2883-2897
    • /
    • 2022
  • According to the Renewable Energy 3020 Implementation Plan announced in 2017 by the South Korean government, the electricity share of renewable energy will be expanded to 20% of the total electricity generation by 2030. Given the intermittency of electricity generation from renewable energy, realization of such a plan presents challenges to managing South Korea's isolated national electric grid and implies potentially large excess electricity generation in certain situations. The purpose of this study is: 1) to develop a model to accurately simulate the effects of excess electricity generation from renewables which would arise during the transition, and 2) to propose strategies to manage excess electricity generation through effective utilization of domestic electricity generating capabilities. Our results show that in periods of greater PV and wind power, namely the spring and fall seasons, the frequency of excess electricity generation increases, while electricity demand decreases. This being the case, flexible operation of coal and nuclear power plants along with LNG and pumped-storage hydroelectricity can be used to counterbalance the excess electricity generation from renewables. In addition, nuclear energy plays an important role in reducing CO2 emissions and electricity costs unlike the fossil fuel-based generation sources outlined in the 8th Basic Plan.

Densities, Viscosities and Excess Properties of 2-Bromopropane - Methanol Binary Mixtures at Temperature from (298.15 to 318.15) K (298.15~318.15 K 에서 2-브로모프로판-메탄올 이성분 혼합물의 밀도, 점성도, 여분 성질)

  • Li, Hua;Zhang, Zhen;Zhao, Lei
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • The densities and viscosities of 2-bromopropane-methanol binary mixtures had been determined using an digital vibrating U-tube densimeter and Ubbelohde capillary viscometer respectively from (298.15 to 318.15) K. The dependence of densities and viscosities on temperature and concentration had been correlated. The excess molar volume and the excess viscosity of the binary system were calculated from the experimental density and viscosity data. The excess molar volumes were related to compositions by polynomial regression and regression parameters and total RMSD deviations were obtained; the excess viscosities was related to compositions by Redlich-Kister equation and regression coefficients and total RMSD deviation of the excess viscosity for 2-bromopropane and methanol binary system were obtained. The results showed that the model agreed very well with the experimental data.

Correlation between Eum, Yang, Ki and Blood Metabolism and Obesity (음양기혈대사(陰陽氣血代謝)와 비만(肥滿)의 상관관계)

  • Shin, Soon Shik
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This paper aims to present a model of obesity and leanness based on eum, yang, ki and blood metabolism of Korean medicine. I analyzed the theory of eum, yang, ki and blood metabolism, yang transforming ki and eum forming the body on Korean medicine, and compared them with energy homeostasis by anabolism and catabolism of modern medicine. In the eum and yang theory, the metabolic process of the human body is dominated by synergism and antagonism between eum force and yang force. When the balance of eum and yang collapses, all the pathological actions of the human body appear, and in the eum and yang metabolic process, an imbalance between yang transforming ki and eum forming the body occurs. The function of yang transforming ki is reduced to ki deficiency, and the function of eum forming the body is increased to blood excess. When blood excess and ki deficiency is given, energy intake increases, energy expenditure decreases, overweight and obesity occur. On the contrary, the function of yang transforming ki is increased to ki excess, and the function of eum forming the body is decreased to blood deficiency. When ki excess and blood deficiency is done, energy intake decreases and energy expenditure increases, the body becomes leanness. When the balance of eum, yang, ki and blood metabolism collapses and becomes blood excess and ki deficiency, overweight and obesity occur, and when ki excess and blood deficiency is done, the body becomes leanness. The energy homeostasis of the human body can be explained by eum, yang, ki and blood metabolism of Korean medicine and it contains the concept of anabolism and catabolism of modern medicine.

Feasibility Study of the Introduction of Hydrogen System and Plus DR on Campus MG

  • Woo, Gyuha;Park, Soojin;Yoon, Yongbeum
    • New & Renewable Energy
    • /
    • v.18 no.1
    • /
    • pp.35-45
    • /
    • 2022
  • The renewable energy based MG is becoming one of the prominent solutions for greenhouse gas and constructing less power lines. However, how to procure the economics of MG considering the CO2 emission and utility network impact is one of major issues as the proportion of renewable resource increases. This paper proposes the feasibility study scheme of campus MG and shows that the LCOE and CO2 emission can be reduced by utilizing the excess power and introducing hydrogen system and plus DR. For this, the three cases: (a) adding the PV and selling excess power to utility, (b) producing and selling hydrogen using excess power, and (c) participating in plus DR are considered. For each case, not only the topology and component capacity of MG to secure economic feasibility, but also CO2 emission and utility network effects are derived. If an electrolyzer with a capacity of 400 kW participates in plus DR for 3,730hours/year, the economic feasibility is securable if plus DR settlement and hydrogen sale price are more than 7.08¢/kWh and 8.3USD/kg or 6.25¢/kWh and 8.6USD/kg, respectively. For this end, continuous technical development and policy support for hydrogen system and plus DR are required.

Evaluation of the Excess Free Energy for Two-Center-Lennard-Jones Liquids Using the Vent Effective Acceptance Ratio

  • Hong, Seong Do
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.7
    • /
    • pp.697-700
    • /
    • 2000
  • A method of calculating the excess Helmholtz free energy from the average of the bent effective acceptance ratio for two-center-Lennard-Jones liquids has been presented. The bent effective acceptance ratio has been newly composed from the acceptan ce ratio for the potential energy difference between a configuration in the Metropolis Monte Carlo procedure and random virtual configuration generated by the separate parallel Monte Carlo procedure and the Boltzmann factor for half the potential energy difference. The excess Helmholtz free energy was calculated directly from the average of the bent effective acceptance ratio through a single Metropolis Monte Carlo run. Because the separate parallel Monte Carlo procedure was used, this method can be applied to molecular dynamics simulations. For two-center-Lennard-Jones liquids, the average of the bent effective acceptance ratio gave better results than use of the modified effective acceptance ratio in the previous work.

Study on The Calculation of The Stored Energy due to Defects at High-Strain-Rate Deformation Using Molecular Dynamics (분자동역학을 이용한 고변형률하에서 결함으로 인한 저장에너지 계산에 관한 연구)

  • Ryu, Han-Kyu;Choi, Deok-Kee
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1139-1144
    • /
    • 2003
  • This paper addresses a theoretical study to calculate the amount of the stored energy due to vacancies during high-strain-rate deformation. The study concerns the role of excess vacancies, which can play an important role to increase the amount of stored energy. Molecular dynamics simulation using a 3D model is carried out and the result clearly shows that the excess vacancies are credited to generation of the stored energy.

  • PDF

Thermodynamic Properties of Caffeine in Compressed Gas

  • Kim, Jeong Rim;Gyeong, Jin Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.432-436
    • /
    • 1995
  • The solubility of caffeine in compressed carbon dioxide has been measured to determine its fugacity coefficient between 330 and 410 K up to 500 bar. The result allows the calculation of the thermodynamic excess functions such as the molar excess enthalpy, the molar excess free energy, and the molar excess entropy. The pressure variations of the molar excess functions of caffeine in the caffeine-CO2 mixture were discussed and also compared them with those in the caffeine-NH3 mixture.

Optimal Design of PV Module with Bypass Diode to Reduce Degradation due to Reverse Excess Current

  • Jung, Tae-Hee;Kang, Gi-Hwan;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.5
    • /
    • pp.279-283
    • /
    • 2014
  • In this paper, we present an economical and practical standard to install a bypass diode in a thin-film PV module. This method helps to reduce heat generation and to prevent module degradation due to excess current from reverse bias. The experimental results confirm that for different numbers of solar cells, there is a relation between the excess reverse current and the degradation of solar cells in a-Si:H modules. The optimal number of solar cells that can be connected per bypass diode could be obtained through an analysis of the results to effectively suppress the degradation and to reduce the heat generated by the module. This technique could be expanded for use in high power crystalline Si PV modules.