• Title/Summary/Keyword: evaluation scale

Search Result 4,701, Processing Time 0.034 seconds

Development of Premarital Preparation Evaluation Scale (결혼준비도 척도 개발 연구-기혼 남.녀를 중심으로)

  • 김혜선;신수아
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.3
    • /
    • pp.41-53
    • /
    • 2002
  • The purpose of this study was to develop a scale for evaluation of premarital preparation. The subjects were 412 married couples(196 males and 216 females) who had been married for 1-37ears. They were selected from Seoul, Incheon, Daejeon, Gwangju, Pusan, and DaeGu. The questionnaire was composed of 82 items. The data was analyzed by frequencies, percentages, factor analysis, Pearson's r, and Cronbach'$\alpha$. The major findings were as followings; 1. The 54 items of 82 items scale were selected through item discriminant method. The discriminant coefficients of the items(Cromer's V ranged from .33 to .68. 2. The 7 factors that were extracted from the factor analysis explained 42% of premarital preparation. The subscales were labelled as rearing child$.$financial management role division, maturity, understanding each other$.$love$.$sex, views about marriage, understanding his/her family and friends, capacity of communication and conflict resolution, and independence from parents. The criterion validity of this scale was assessed by the correlation between this premarital preparation scale and marital stability. All coefficients were significant(ranged from r=.10 to .44, p<.01, p<.001). 3. The internal consistency of this scale was acceptable(Cronbach's $\alpha$=.91).

Correlation Between Selective Motor Control Test and Functional Performance Evaluation in Children With Spastic Cerebral Palsy (선택적 운동 조절 척도와 기능적 수행도 평가 간의 상관: 경직형 뇌성마비 아동을 대상으로)

  • Park, Eun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.232-239
    • /
    • 2012
  • The purpose of this study was to investigate the relationship among functional evaluation systems, the Selective Motor Control Scale (SMC scale), the Gross Motor Function Classification System (GMFCS), the Gross Motor Function Measure (GMFM) and Activities of daily living in children with spastic cerebral palsy and to provide the foundation data about SMC scle for evaluation system of abilities of selective motor control in children with spastic cerebral palsy. For this, sixty eight children with spastic cerebral palsy were participated in this study. The children were evaluated by using the SMC scale for their selective motor control ability and by using the GMFCS and GMFM for their gross motor function. The activities of daily living were assessed by using the Functional Independence Measure of Children (WeeFIM). There were a significant correlation between the SMC scale and the GMFCS (r = -.485, p < .05). The good correlation between the SMC scale and GMFM was found (r = .482, p < .05). The activities of daily living were not a significant correlation with SMC scale (r = .019, p > .05). The SMC scale in practice will provide usefulness for assessment of abilities of selective motor control in children with spastic cerebral palsy.

Usability Evaluation Scale for Product of Intelligent Homecare based on Retail Consumer

  • KWON, Jieun;LEE, Jin-Suk
    • Journal of Distribution Science
    • /
    • v.17 no.12
    • /
    • pp.55-62
    • /
    • 2019
  • Purpose: The number intelligent homecare products are focused on the development of technology, resulting in a lack of realistic environments or requirements for consumers. The purpose of this paper is to define the consumer and context for intelligent homecare products and to develop a usability evaluation scale. Research design, data and methodology: For this study, first, consumer and contexts related to intelligent homecare products were analyzed through literature review. Second, the primary usability evaluation factors were derived for intelligent homecare products by collecting the factors related to usability evaluation and conducting in-depth interviews with experts. Third, the second usability evaluation factors were derived through survey and statistical analysis based on the derived usability evaluation factors. Results: As a result, users of intelligent homecare products were classified as primary users and secondary consumers and six related contexts. The usability evaluation scale was established with four factors - Functionality, Error, Convenience, and Emotion - and 13 items. Conclusions: This study can be the basis for developing and distributing products that meet the consumer environment and requirements related to intelligent homecare products that will contribute to securing the competitiveness of companies and developing the technology and service value of related industries.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

27 Case of Venesection with Negative Pressure Therapy(Buhang) Operated at CV17 (Danjuong) on Sudden palpitation : Case report (전중(膻中)(CV17)혈(穴)에 자락부항법(刺絡附缸法)을 시술(施術)한 경계(驚悸).정충환자(怔忡患者) 27례(例) 대한 증례보고(症例報告))

  • Jeong, Yen-Tag;Yim, Yun-Kyoung
    • Journal of Haehwa Medicine
    • /
    • v.16 no.2
    • /
    • pp.199-210
    • /
    • 2007
  • Objective & Methods : The case report is to observe 27 case of venesection with negative pressure therapy(buhang) operated at CV17 (Danjuong) on sudden palpitation. We carried out to analyze the distribution and Martin's evaluation and weighted scale by sex & age, patient conditional grade, accompanied symptoms, duration, number of treatments as well. Results : 1. Forties is significantly distributed on sudden palpitation. 2. Depression instance out of many accompanied symptoms is significantly distributed. 3. Mean of operant frequency is significantly resulted on 10 or 11 times. 4. The improvement on the weighted scale is over one grade. 5. Younger is high on the assessment of treatment on Martin's evaluation and weighted scale by age, while older is low. 6. Lesser one year and more three years is some significantly resulted on the assessment of treatment on Martin's evaluation and weighted scale by duration. 7. Pleurodynia, insomnia, distress in the stomach are effective more 90%, and depression, asthma are more 80% on the assessment of treatment on Martin's evaluation by accompanied symptoms, while asthma and pleurodynia are very significantly resulted on the assessment of treatment on weighted scale. 8. The assessment of treatment on Martin's evaluation and weighted scale have no connection with operant frequency. Conclusion : These results suggest that venesection with negative pressure therapy(buhang) operated at CV17 (Danjuong) has a therapeutic effect on on sudden palpitation.

  • PDF

Development and Psychometric Evaluation of a Scale to Measure Health Behaviors of Adolescents (청소년의 건강행위 측정을 위한 도구개발 및 평가)

  • Shin, Yun-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.820-830
    • /
    • 2010
  • Purpose: The purpose was to develop a preliminary scale to measure Korean adolescents' health behaviors through a qualitative approach, to evaluate the scale psychometrically, and to develop a final scale. Methods: Participants were 61 adolescents for qualitative interviews and 1,687 adolescents for the psychometric evaluation. Procedure included content analysis of interviews to identify health behavior categories for Korean adolescents, pre-test to confirm that preliminary scale items were understandable, content validity by an expert panel, development of the web-based computer-assisted survey (CAS), and psychometric analysis to determine reliability and validity of the final scale. Results: A final scale was developed for both paper-and-pencil and CAS. It consisted of 14 health behaviors (72 items), including stress and mental health (10), sleep habits (5), dietary habits (12), weight control (4), physical activity (4), hygiene habits (5), tobacco use (5), substance use (2), alcohol consumption (4), safety (4), sexual behavior (9), computer use (3), health screening (4), and posture (1). Conclusion: The scale's strong points are: 1) Two thirds of the final scale items are Likert scale items, enabling calculation of a health behavior score. 2) The scale is appropriate to Korean culture. 3) The scale focuses on concrete health behaviors, not abstract concepts.

A Study of the Evaluation Scale of Traffic Noise base on Sound Quality Index (음질을 기초한 교통소음의 척도화에 관한 연구)

  • Hur, Deog-Jae;Jo, Kyoung-Sook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1280-1284
    • /
    • 2006
  • This paper describes the methodology for environmental assessments of traffic noise sources. An attempt is made to establish evaluation scale relationships between noise quality Parameters and subjective degrees annoyance. Subjective experimental was conducted to determine the subjective degrees annoyance that scaling score compare with reference and varieties noise source about modified traffic noises with $40{\sim}85dB$. Also a correlation analysis between noise rating index and satisfactory percentage of the noise dose response curves varied with response was conducted. As a result of study, subjective annoyance degree has not correlation of proportional linearity to the A weight noise level, but has correlation of proportional linearity to the index composed to loudness and tonality. It is suggested to be resonable level 4.9 (equivalence about 53dB) index on the out door noise limits for traffic noise and to be 6 step scale base on the linearity for evaluation traffic noise.

  • PDF

Development of a Piping Integrity Evaluation Simulator Based on the Hardware-in-the-Loop Simulation (하드웨어-인-더-루프 기반의 배관 평가 시뮬레이터의 개발)

  • Kim, Yeong-Jin;Heo, Nam-Su;Cha, Heon-Ju;Choe, Jae-Bung;Pyo, Chang-Ryul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.7
    • /
    • pp.1031-1038
    • /
    • 2001
  • In order to verify the analytical methods predicting failure behavior of cracked piping, full-scale pipe tests are crucial in nuclear power plant piping. For this reason, series of international test programs have been conducted. However, full-scale pipe tests require expensive testing equipment and long period of testing time. The objective of this paper is to develop a test system which can economically simulate the full-scale pipe test regarding the integrity evaluation. This system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system was developed for the integrity evaluation of nuclear piping based on the methodology of hardware-in-the-loop (HiL) simulation. Using this simulator, the piping integrity can be evaluated based on the elastic-plastic behavior of full-scale pipe, and the high cost full-scale pipe test may be replaced with this economical system.

A study on evaluator factors affecting physician-patient interaction scores in clinical performance examinations: a single medical school experience

  • Park, Young Soon;Chun, Kyung Hee;Lee, Kyeong Soo;Lee, Young Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.2
    • /
    • pp.118-126
    • /
    • 2021
  • Background: This study is an analysis of evaluator factors affecting physician-patient interaction (PPI) scores in clinical performance examination (CPX). The purpose of this study was to investigate possible ways to increase the reliability of the CPX evaluation. Methods: The six-item Yeungnam University Scale (YUS), four-item analytic global rating scale (AGRS), and one-item holistic rating scale (HRS) were used to evaluate student performance in PPI. A total of 72 fourth-year students from Yeungnam University College of Medicine in Korea participated in the evaluation with 32 faculty and 16 standardized patient (SP) raters. The study then examined the differences in scores between types of scale, raters (SP vs. faculty), faculty specialty, evaluation experience, and level of fatigue as time passes. Results: There were significant differences between faculty and SP scores in all three scales and a significant correlation among raters' scores. Scores given by raters on items related to their specialty were lower than those given by raters on items out of their specialty. On the YUS and AGRS, there were significant differences based on the faculty's evaluation experience; scores by raters who had three to ten previous evaluation experiences were lower than others' scores. There were also significant differences among SP raters on all scales. The correlation between the YUS and AGRS/HRS declined significantly according to the length of evaluation time. Conclusion: In CPX, PPI score reliability was found to be significantly affected by the evaluator factors as well as the type of scale.

Machine learning-based evaluation technology of 3D spatial distribution of residual radioactivity in large-scale radioactive structures

  • UkJae Lee;Phillip Chang;Nam-Suk Jung;Jonghun Jang;Jimin Lee;Hee-Seock Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3199-3209
    • /
    • 2024
  • During the decommissioning of nuclear and particle accelerator facilities, a considerable amount of large-scale radioactive waste may be generated. Accurately defining the activation level of the waste is crucial for proper disposal. However, directly measuring the internal radioactivity distribution poses challenges. This study introduced a novel technology employing machine learning to assess the internal radioactivity distribution based on external measurements. Random radioactivity distribution within a structure were established, and the photon spectrum measured by detectors from outside the structure was simulated using the FLUKA Monte-Carlo code. Through training with spectrum data corresponding to various radioactivity distributions, an evaluation model for radioactivity using simulated data was developed by above Monte-Carlo simulation. Convolutional Neural Network and Transformer methods were utilized to establish the evaluation model. The machine learning construction involves 5425 simulation datasets, and 603 datasets, which were used to obtain the evaluated results. Preprocessing was applied to the datasets, but the evaluation model using raw spectrum data showed the best evaluation results. The estimation of the intensity and shape of the radioactivity distribution inside the structure was achieved with a relative error of 10%. Additionally, the evaluation based on the constructed model takes only a few seconds to complete the process.