• Title/Summary/Keyword: evaluation of grasping

Search Result 89, Processing Time 0.027 seconds

A Study on the Motion Control of 3D Printed Fingers (3D 프린팅 손가락 모형의 동작 제어에 관한 연구)

  • Jung, Imjoo;Park, Ye-eun;Choi, Young-Rim;Kim, Jong-Wook;Lee, Sunhee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.3
    • /
    • pp.333-345
    • /
    • 2022
  • This study developed and evaluated the motion control of 3D printed fingers applied to smart gloves. Four motions were programmed by assembling the module using the Arduino program: cylindrical grasping, spherical grasping, tip-to-tip pinch gripping, and three-jaw pinch gripping. Cap and re-entrant (RE) strip types were designed to model the finger. Two types of modeling were printed using filaments of thermoplastic elastomer (TPE) and thermoplastic polyurethane (TPU). The prepared samples were evaluated using three types of pens for cylidrical grasping, three types of balls for spherical grasping, and two types of cards for tip-to-tip pinch gripping and three-jaw pinch gripping. The motion control of fingers was connected using five servo motors to the number of each control board. Cylindrical and spherical grasping were moved by controlling the fingers at 180° and 150°, respectively. Pinch gripping was controlled using a tip-to-tip pinch motion controlled by the thumb at 30° and index-middle at 0° besides a three-jaw pinch motion controlled by the thumb-index finger-middle at 30°, 0°, and 0°, respectively. As a result of the functional evaluation, the TPE of 3D-printed fingers was more flexible than those of TPU. RE strip type of 3D-printed fingers was more suitable for the motion control of fingers than the 3D-printed finger.

Device for Assisting Grasping Function (2nd Report : Maneuverability Evaluation)

  • Moromugi, S.;Okamoto, A.;Kim, S.H.;Tanaka, H.;Ishimatsu, T.;Koujina, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2665-2669
    • /
    • 2003
  • A wearable device to assist fingering function for disabled is developed in this study. This is the second paper to report the progress in development of this assisting device. The device is developed for a patient who suffers from cervical spinal cord injury. In the first paper, it was reported that the patient could successfully pick up several types of objects with his paralyzed fingers by using this device. As a next step, the maneuverability of the device under grasping operation is discussed in this paper. Maneuverability of the system is experimentally evaluated. The dexterity in controlling finger force is compared between the cases that non-disabled examinees operate their finger with inherent abilities and that a disabled examinee operates his finger by using the assisting device.

  • PDF

Development of Two-Finger Force Measuring System to Measure Two-Finger Gripping Force and Its Characteristic Evaluation (단축 힘센서를 이용한 두 손가락 잡기 힘측정장치 개발 및 특성평가)

  • Kim, Hyeon-Min;Shin, Hi-Suk;Yoon, Joung-Won;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.172-177
    • /
    • 2011
  • Finger patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers(thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). At present, most hospitals have used a thin plastic-plate for measuring the two-finger grasping force, and we can only judge that they can grasp the plate with their two-finger through it, because the plate can't measure the two-finger grasping force. But, recently, the force measuring system for measuring two-finger grasping force was developed using three-axis force sensor, but it is very expensive, because it has a three-axis force sensor. In this paper, two-finger force measuring system with a one-axis force sensor which can measure two-finger grasping force was developed. The one-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP(Digital Signal Processing). Also, the grasping force test of men was performed using the developed two-finger force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods, and the system can be used for measuring two-finger grasping force.

Relationship Between a New Functional Evaluation Model and the Fugle-Meyer Assessment Scale for Evaluating the Upper Extremities of Stroke Patients

  • Kim, Jung-Hyun;Kim, Hyun-Jin;Lee, Seung-Gu;Song, Chang-Ho
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the relationship between a functional evaluation model and the Fugl-Meyer assessment (FMA) scale in evaluating the upper extremities of stroke patients Methods: Thirty-eight stroke patients were evaluated using the FMA and performed reaching and grasping motions using a three-dimensional motion analysis (Qquas 1 series, Qualisys AB, Sweden). The participants sat on a chair with a backrest. The position of the cup was located at a distance of 80% to the front arm length. The markers were attached to the sternum, acromion, elbow lateral epicondyle, ulnar styloid process, three metacarpal heads, and the distal phalanges of the thumb and index finger. The variables of the correlation between the functional evaluation model and the FMA scale were analyzed. Multiple regression (stepwise) was used to investigate the effect of the kinematic variables. Results: A significant negative correlation was found between the movement time (p < 0.05), movement unit (p < 0.05), and trunk displacement values (p < 0.05) in the FMA total scores, while a positive correlation was found between the peak velocity (p < 0.05) and maximum grip aperture values (p < 0.05). As a result of the multiple regression analysis, the most significant factor was the movement unit, followed by the general movement assessment and trunk displacement. The explained FMA total score value was 62%. Conclusion: This study presents a new functional evaluation model for assessing the reaching and grasping ability of stroke patients. The factors of the proposed functional evaluation model showed significant correlations with the FMA scale scores and confirmed that the new functional evaluation model explained the FMA by 67%. This suggests a new functional evaluation model for reaching and grasping stroke patients.

Development of Cylindrical-type Finger Force Measuring System Using Two-axis Force/Moment Sensor and its Characteristic Evaluation (2축 힘/모멘트센서를 이용한 원통형 손가락 힘측정장치 개발 및 특성평가)

  • Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.5
    • /
    • pp.484-489
    • /
    • 2011
  • Some patients can't use their hands because of inherent and acquired paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a cylinder which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the cylinder. A cylindrical-type finger force measuring system which can measure the grasping force of patients' fingers should be developed. This paper looks at the development of a cylindrical-type finger force measuring system with two-axis force/moment sensor which can measure grasping force. The two-axis force/moment sensor was designed and fabricated, and the high-speed force measuring device was designed and manufactured by using DSP (digital signal processing). Also, cylindrical-type finger force measuring system was developed using the developed two-axis force/moment sensor and the high-speed force measuring device, and the grasping force tests of men were performed using the developed system. The tests confirm that the average finger forces of right and left hands for men were about 186N and 172N respectively.

A Study of Selecting Sequential Viewpoint and Examining the Effectiveness of Omni-directional Angle Image Information in Grasping the Characteristics of Landscape (경관 특성 파악에 있어서의 시퀀스적 시점장 선정과 전방위 화상정보의 유효성 검증에 관한 연구)

  • Kim, Heung Man;Lee, In Hee
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • Relating to grasping sequential landscape characteristics in consideration of the behavioral characteristics of the subject experiencing visual perception, this study was made on the subject of main walking line section for visitors of three treasures of Buddhist temples. Especially, as a method of obtaining data for grasping sequential visual perception landscape, the researcher employed [momentum sequential viewpoint setup] according to [the interval of pointers arbitrarily] and fisheye-lens-camera photography using the obtained omni-directional angle visual perception information. As a result, in terms of viewpoint selection, factors like approach road form, change in circulation axis, change in the ground surface level, appearance of objects, etc. were verified to make effect, and among these, approach road form and circulation axis change turned out to be the greatest influences. In addition, as a result of reviewing the effectiveness via the subjects, for the sake of qualitative evaluation of landscape components using the VR picture image obtained in the process of acquiring omni-directional angle visual perception information, a positive result over certain values was earned in terms of panoramic vision, scene reproduction, three-dimensional perspective, etc. This convinces us of the possibility to activate the qualitative evaluation of omni-directional angle picture information and the study of landscape through it henceforth.

Recognition on Hospital Evaluation Result, Influences and Task of Mid Sized Hospital Employee Having Experience of the Hospital Evaluation (중소병원 종사자의 의료기관평가 수검 후 평가결과 및 영향.과제에 대한 인식)

  • Yi, Ga-Eon;Park, Young-Hee
    • The Korean Journal of Health Service Management
    • /
    • v.3 no.2
    • /
    • pp.29-43
    • /
    • 2009
  • The purpose of this study is to provide basic material about the improvement method of the hospital evaluation system by grasping recognition, corresponding behavior to evaluation, influence and problems about the hospital evaluation system with respect to the employee of mid sized hospitals having relatively poorer environment. In this study were used 518 questionnaires to hospital employee working at 20 general hospitals in Pusan, Kyungnam with less than 500 beds and having experience of the hospital evaluation during 2005~2007. As a result of the research, they felt the investigation tool used for the hospital evaluation has too many items and it could be difficult to reflect characteristics of each hospital. It appeared that utilization of the report result after the hospital evaluation was helpful for grasping a part necessary for hospital improvement and the present level of hospitals and increase of interest about medical service quality improvement of the a hospital director or hospital employee. They trusted the result of the hospital evaluation to some degree, and recognized it helps the patients to select a hospital and increase rights-to-know. Hospital employee recognized the necessity and showed high interest and participation, but they didn't sympathize in the propriety and the feasibility of the hospital evaluation items. High degree evaluated hospital employee receive hospital evaluation system positively and think hospital services to be improve after taking hospital evaluation. The hospital evaluation should make the hospital to effort to achieve medical quality improvement to its purpose. Also, systematic reformation will be necessary to reflect characteristics of the hospital that has relatively small scale or locates in poor environment.

  • PDF

A Study on the Medium Facilities in Barrier-Free Certification Evaluation Items (장애물 없는 생활환경 인증 사례를 통한 매개시설 평가항목 분석)

  • Lee, Kyoo-Il;Kim, In-Soon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.2
    • /
    • pp.33-43
    • /
    • 2012
  • This study purposes to present the improvement on the index by analyzing concretely the certification and evaluation index and the actual certification acquisition focusing on the buildings acquiring the barrier-free (BF) certification. So, after analyzing the screening results of the buildings acquiring the BF certification and then grasping the general application level based on the above analysis, this study tries to present the improvement on the BF certification index by analyzing the detailed applications of the BF certification-acquired buildings and then grasping the problems on the evaluation index of the current certification system. It was analyzed that the items which applied the BF construction method generalized to the common buildings through the Act on the Promotion of Convenience in medium facilities and the items with higher distribution points were shown as high in terms of points and the acquired point level of items which influenced by the shape and condition of side and land to defile the appearance of buildings were low.

SERVICE QUALITY EVALUATION INDICATORS FOR ASP-BASED PROJECT MANAGEMENT INFORMATION SYSTEM

  • Lee, Seul-Ki;Yu, Jung-Ho;Kim, Chang-Duk
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1453-1462
    • /
    • 2009
  • It is very important for performance of information system that we make an effort to raise user's satisfaction by continuously grasping user's requirement by evaluation of PMIS based on ASP service quality and reflecting this to information system. However, It is lack that developments of suitable evaluation index of PMIS based on ASP service quality. Hereupon, In this study, we propose the evaluation indicators. First, The evaluation area is classified by form the foundation of D & M IS Success Model (2003); system quality, information quality, service quality. Second, The detail evaluation item which include considerations which are gotten through investigation of the construction industry and PMIS based on ASP is grouping by form the foundation SERVQUAL which is a service quality evaluation tool proposed PZB(1988). It is suitable to evaluate PMIS based on ASP service quality in construction industry and able to evaluate various aspects.

  • PDF

Evaluation of shadow influence in NOAA AVHRR data

  • Kim, Dong-Hee;Tateishi, Ryutaro;Tsend-Ayush, Javzandulam
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.357-359
    • /
    • 2003
  • There is various problem in grasping change of vegetation by NDVI, PVI, etc. It is very difficult especially to remove various noise ingredients in the received satellite data. Until now, it is difficult to compensate for shadow effect when NDVI is used in vegetation analysis. The essence of this study is to describe data simulation and then applied the result to the NOAA AVHRR data. When a pixel contains shadow more than 60% then this pixe1 is extracted for shadow effects on NDVI.

  • PDF