• 제목/요약/키워드: evaluation module

검색결과 955건 처리시간 0.029초

원전 배관 파단전누설 평가를 위한 탄소성 파괴역학 평가 프로그램 개발 (Development of Elastic-Plastic Fracture Mechanics Evaluation Program for Leak-Before-Break Analysis of Nuclear Piping)

  • 박준근;허남수;김예지;이상민
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.35-46
    • /
    • 2020
  • In this paper, a fracture mechanics evaluation system which can be used to assess the leak-before-break (LBB) of nuclear piping is developed. Existing solutions for calculating the fracture mechanics parameters (J-integral and crack opening displacement) required for LBB evaluation were firstly presented. Then a module for calculating J-integral and COD was developed, with an additional module for predicting the critical load based on the crack driving force diagram to finally develop a fracture mechanics evaluation system. To confirm the validity of the proposed evaluation system, finite element (FE) analysis was performed, and the FE J-integral and COD results were compared with prediction results using the J-integral and COD estimations program. Furthermore, the critical load assessment module was verified by comparing the actual pipe test results (Battelle test data) with prediction results using the proposed program.

정형 기법을 이용한 하드웨어 AES 모듈 백도어 탐색 연구 (Study of Hardware AES Module Backdoor Detection through Formal Method)

  • 박재현;김승주
    • 정보보호학회논문지
    • /
    • 제29권4호
    • /
    • pp.739-751
    • /
    • 2019
  • 임베디드 기기의 보안성이 주요한 문제로 부상하고 있다. 관련된 문제 중 특히 공급망 공격은 국가 간의 분쟁으로 이어질 수 있어 심각한 문제로 대두되고 있다. 공급망 공격을 완화하기 위하여 하드웨어 구성요소, 특히 AES와 같은 암호 모듈에 대한 CC(Common Criteria) EAL(Evaluation Assurance Level) 5 이상 고등급 보안성 인증 및 평가가 필요하다. 고등급 보안성 인증 및 평가를 위하여 암호 모듈에 대한 은닉 채널, 즉 백도어를 탐지하는 것이 필요하다. 그러나 기존의 연구로는 암호 모듈 그 중 AES의 비밀 키를 복구시킬 수 있는 정보가 유출되는 백도어를 탐지하지 못하는 한계가 있다. 따라서 본 논문은 기존의 하드웨어 AES 모듈 백도어의 정의를 확장하여 개선시킨 새로운 정의를 제안하고자 한다. 또한, 이 정의를 이용하여 기존 연구가 탐지하지 못했던 백도어를 탐색하는 과정을 제시한다. 이 탐색 과정은 Verilog HDL (Hardware Description Language)로 표현된 AES 모듈을 정형 기법 도구인 모델 체커(Model Checker) NuSMV를 이용하여 검증하는 것으로 백도어를 탐색한다.

Optimal Hyper Analytic Wavelet Transform for Glaucoma Detection in Fundal Retinal Images

  • Raja, C.;Gangatharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1899-1909
    • /
    • 2015
  • Glaucoma is one of the most common causes of blindness which is caused by increase of fluid pressure in the eye which damages the optic nerve and eventually causing vision loss. An automated technique to diagnose glaucoma disease can reduce the physicians’ effort in screening of Glaucoma in a person through the fundal retinal images. In this paper, optimal hyper analytic wavelet transform for Glaucoma detection technique from fundal retinal images is proposed. The optimal coefficients for transformation process are found out using the hybrid GSO-Cuckoo search algorithm. This technique consists of pre-processing module, optimal transformation module, feature extraction module and classification module. The implementation is carried out with MATLAB and the evaluation metrics employed are accuracy, sensitivity and specificity. Comparative analysis is carried out by comparing the hybrid GSO with the conventional GSO. The results reported in our paper show that the proposed technique has performed well and has achieved good evaluation metric values. Two 10- fold cross validated test runs are performed, yielding an average fitness of 91.13% and 96.2% accuracy with CGD-BPN (Conjugate Gradient Descent- Back Propagation Network) and Support Vector Machines (SVM) respectively. The techniques also gives high sensitivity and specificity values. The attained high evaluation metric values show the efficiency of detecting Glaucoma by the proposed technique.

원전 ISI UT 자동 결함평가 및 판정 모듈 개발 (Development of ISI UT Auto Flaw Evaluation and Acceptance Module of Nuclear Power Plants)

  • 박익근;박은수;김현묵;김정석;엄병국;이종포
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.212-218
    • /
    • 2000
  • The importance and role of pre-/in-service inspection(PSI/ISI) for nuclear power plant(NPP) components are intimately related to plant design, safety, reliability, operation, etc. In this paper, for an effective and efficient management of large amounts of PSI/ISI data in NPPs, an intelligent database program(WS-IDPIN) for PSI/ISI data management of NPP was developed. WS-IDPIN program enables the prompt extraction of previously conducted PSI/ISI conditions and results so that the time-consuming data management, painstaking data processing and analysis in the past are avoided. Furthermore, development of ISI UT auto flaw evaluation and acceptance module based on ASME Code Sec. XI were presented. This module can be used for any angle beam examination from flat plate to spherical shapes as selected by the proper azimuthal angle. This program can be further developed as a unique PSI/ISI data management expert system.

  • PDF

의료기기 내장형 소프트웨어 품질평가 시험모듈 개발 (Development of Test Module for Medical Embedded Software Quality Evaluation)

  • 양해술;이하용;이정림;김혁주
    • 정보처리학회논문지D
    • /
    • 제13D권2호
    • /
    • pp.259-270
    • /
    • 2006
  • 의료기기 내장형 소프트웨어는 인간의 생명과 직결되는 의료기기를 제어하는 소프트웨어이기 때문에 높은 품질 수준을 요구한다. 의료기기 내장형 소프트웨어의 높은 품질 요구를 만족시키기 위해서는 그 요구사항에 적합한 품질시험 모듈을 개발하여 적용하고 결과를 피드백하여 소프트웨어의 품질 결함을 보완하는 과정이 필요하다. 본 연구에서는 ISO/IEC 12119를 기반으로 의료기기 내장형 소프트웨어를 시험하여 결과를 산출할 수 있는 시험모듈과 품질검사표를 개발하여 의료용 소프트웨어 시험에 적용할 수 있도록 하였다.

후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술 (A technology of realistic multi-media display and odor recognition using olfactory sensors)

  • 이현구;노용완
    • 디지털산업정보학회논문지
    • /
    • 제6권4호
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

태양광발전시스템 인버터 용량 산정에 관한 연구 (A Study on the Photovoltaic System Inverter Sizing)

  • 이경수
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.804-810
    • /
    • 2016
  • Photovoltaic system construction of the module capacity in domestic is specified criteria to less than 105% of the inverter capacity. However, the modules are installed in the outdoor actual output is reduced due to factors such as the irradiation intensity, module surface temperature. Thus, it needs the capacity of the inverter to be designed according to the actual module output. In this paper, the first approach to find the actual module output is to analyze the actual PV system monitoring data. Next, four sites where the loss analysis, system utilization, inverter utilization, and the ratio of the inverter overload are performed using PVSYST software. By changing the ratio of the module capacity, the inverter capacity of the site B is confirmed 20% less than the module capacity. Site A, C, D are identified as the ratio of the inverter capacity is 10% less than the module capacity.

Development of Ice Load Generation Module to Evaluate Station-Keeping Performance for Arctic Floating Structures in Time Domain

  • Kang, Hyun Hwa;Lee, Dae-Soo;Lim, Ji-Su;Lee, Seung Jae;Jang, Jinho;Jung, Kwang Hyo;Lee, Jaeyong
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.394-405
    • /
    • 2020
  • To assess the station-keeping performance of floating structures in the Arctic region, the ice load should be considered along with other environmental loads induced by waves, wind, and currents. However, present methods for performance evaluation in the time domain are not effective in terms of time and cost. An ice load generation module is proposed based on the experimental data measured at the KRISO ice model basin. The developed module was applied to a time domain simulation. Using the results of a captive model test conducted in multiple directions, the statistical characteristics of ice loads were analyzed and processed so that an ice load corresponding to an arbitrary angle of the structure could be generated. The developed module is connected to commercial dynamic analysis software (OrcaFlex) as an external force input. Station-keeping simulation in the time domain was conducted for the same floating structure used in the model test. The mooring system was modeled and included to reflect the designed operation scenario. Simulation results show the effectiveness of the proposed ice generation module and its application to station-keeping performance evaluation. Considering the generated ice load, the designed structure can maintain a heading angle relative to ice up to 4°. Station-keeping performance is enhanced as the heading angle conforms to the drift direction. It is expected that the developed module will be used as a platform to verify station-keeping algorithms for Arctic floating structures with a dynamic positioning system.

높이 축소형 고효율 냉각모듈의 성능 평가에 관한 연구 (Studies on the Performance Evaluation of Downsized High-efficiency Cooling Module)

  • 정정훈;신윤혁;박성욱;정순안;김성철
    • 한국자동차공학회논문집
    • /
    • 제19권6호
    • /
    • pp.61-67
    • /
    • 2011
  • The cooling module needs enough space (or distance) from hood to absorb the energy from any pedestrian collision. Downsized cooling module for pedestrian protection is important to reduce the severity of pedestrian injury. When a vehicle collision happens, the downsized cooling module is required to reduce the risk of injury to the upper legs of adults and the heads of children. In this study, the performance of cooling module to cool the engine was investigated under 25% height reduction. The heat dissipation and pressure drop characteristics have been experimentally studied with the variation of coolant flow rate, air inlet velocity and A/C operation ON/OFF for the downsized cooling module. The results indicated that the cooling performance was about 94% level compared to that of the conventional cooling module. Therefore, we checked that the cooling module had good performance, and expected that the cooling module could meet the same cooling performance as conventional cooling module through optimization of components efficiency.

중소기업용 혼합형 자동창고에 대한 주행시간 모형 (Travel Time Models of a Hybrid Automated Storage/Retrieval Module for Small and Medium-Sized Enterprises)

  • 이문규
    • 산업공학
    • /
    • 제17권spc호
    • /
    • pp.52-61
    • /
    • 2004
  • During the past decades automated storage/retrieval (AS/R) systems have been dominantly implemented in most industrial fields due to their handling efficiency and high utilization of storage space. Such AS/R systems consist of several modules each of which contains two racks and a S/R machine. This paper proposes a design of the hybrid AS/R module which can be adopted without too much initial expenditure by most of small-and-medium sized companies. The hybrid module consists of an AS/R module on the upper floor and a traditional warehouse module on the lower floor. For the AS/R module, analytical expressions of the expected travel times for the S/R machine and the elevator per operation are derived. The expected travel times represent the performance of the module and thus can be used for its economic design.