• Title/Summary/Keyword: evaluation case

Search Result 8,079, Processing Time 0.045 seconds

Removal of Soluble Fe(II) using Reactive Media Coated with both Fe and Mn (철과 망간이 동시에 코팅된 반응성 매질을 이용한 용존 Fe(II) 제거)

  • Min, Sang-Yoon;Chang, Yoon-Young;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.85-92
    • /
    • 2011
  • Evaluation of the removal efficiencies of Fe(II) by reactive sand media coated with manganese (MCS), iron (ICS) and both of iron and manganese (IMCS) was investigated as functions of solution pH ranging from 2 to 9, reaction time and concentration of Fe(II) in a batch reactor using each reactive medium and additional oxidants such as $KMnO_4$ and NaOCl. When only Fe(II) was present in solution without any reactive medium, removal of Fe(II) was quite low below pH 5 due to a slow oxidation of Fe(II) and/or negligible precipitation but greatly increased above pH 5 due to a rapid oxidation of Fe(II) and subsequent precipitation of oxidized Fe species. ICS showed negligible efficiency on the removal of Fe(II) through adsorption. However, an efficient removal of Fe(II) was observed at low solution pH in the presence of IMCS or MCS through rapid oxidation and subsequent precipitation. Removal efficiency of Fe(II) by IMCS in the presence or absence of NaOCl was quite similar. Removal rate of Fe(II) by IMCS and additional oxidants gradually increased as the solution pH increased. From the kinetic experiments, removal pattern of Fe(II) was better described by pseudo-second-order equation than pseudo-first-order equation. A rapid removal of Fe(II) using IMCS in the presence of $KMnO_4$ was observed in the first 10 min. The initial removal rate of Fe(II) using $KMnO_4$ was 14,286 mg/kg hr. In case of using NaOCl, the removal of Fe(II) occurred rapidly in the first 6 hrs and then reached the near-equilibrium state. Removal of Fe(II) on IMCS was well expressed by Langmuir isotherm and the maximum removal capacity of Fe(II) was calculated as 1,088 mg/kg.

Evaluation of Spatial and Temporal Variations of Water Quality in Lake Shihwa and Outer Sea by Using Water Quality Index in Korea: A Case Study of Influence of Tidal Power Plant Operation (수질평가지수를 이용한 시화호 내측 및 외측 해역의 시·공간적 수질 변화 평가: 조력발전소 가동에 따른 영향 연구)

  • Ra, Kongtae;Kim, Joung-Keun;Kim, Eun-Soo;Kim, Kyung-Tae;Lee, Jung-Moo;Kim, Sung-Keun;Kim, Eu-Yeol;Lee, Seung-Yong;Park, Eun-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.102-114
    • /
    • 2013
  • The basin of Lake Shihwa is one of highly industrialized region of Korea and a current environmental issue of study area is the operation of tidal power plant (TPP) to improve water quality. The application of water quality index (WQI) which integrates five physiochemical parameters (transparency, DO, DIN, DIP and chlorophyll-a) of water quality in Lake Shihwa and outer sea during 2011~2012 were performed not only to evaluate the spatial and temporal distribution of the water quality but also to assess the effect of water quality improvement by the operation of tidal power plant. The higher WQI values were observed in monitored sites near the industrial complexes in Lake Shihwa and the outfall of wastewater treatment plants (WWTPs) in outer sea. This indicates that the quality of seawater is influenced by diffuse non-point sources from industrial, municipal and agricultural areas in Lake Shihwa and by point sources from the effluence of municipal and industrial wastewater throughout WWTPs in outer sea. Mean WQI value decreased from 53.0 in 2011 to 42.8 in 2012 of Lake Shihwa. Water quality has improved significantly after TPP operation because enhancement of seawater exchange between Lake Shihwa and outer sea leads to improve a hypoxic condition which is primarily a problem in Lake Shihwa. Mean WQI of outer sea showed similar values between 2011 and 2012. However, the results of hierarchical cluster analysis and the deterioration of water quality in summer season indicate that the operation of tidal power plant was not improved the water quality in the upper most area of Lake Shihwa. To successfully improve overall water quality of Lake Shihwa, it is urgently necessary to manage and reduce of non-point pollution sources of the basin of Lake Shihwa.

Residual characteristics of tolclofos-methyl treated by seed dressing in ginseng (인삼 중 종자분의 처리 tolclofos-methyl의 잔류 특성)

  • Noh, Hyun-Ho;Lee, Jae-Yun;Park, So-Hyun;Lee, Kwang-Hun;Park, Hyo-Kyoung;Oh, Jae-Ho;Im, Moo-Hyeog;Kwon, Chan-Hyeok;Lee, Joong-Keun;Woo, Hee-Dong;Kwon, Ki-Sung;Kyung, Kee-Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.217-221
    • /
    • 2012
  • This study was carried out to evaluate residual characteristics of tolclofos-methyl in ginseng and elucidate the reason for its high detection rate from fresh ginseng selling at markets. Seeds of ginseng were sowed after seed dressing with tolclofos-methyl and after a year of growth, the young seedlings were transplanted to field. They were then harvested annually until three-years of growth and the pesticide residue was analyzed in them. LOD and LOQ of the pesticide were 0.001 and 0.003 mg/kg, respectively. Recovery test was carried out to validate the analytical method for tolclofos-methyl in ginseng. The ginseng seedlings were fortified with the test pesticide at the level of LOQ, ten times of LOQ and maximum residue concentration of tolclofos-methyl. Its recovery ranged from 77.37 to 100.16%. Residual concentration of tolclofos-methyl in ginseng seedlings just before transplanting and two-year-old ginseng were from 7.58 to 8.05 and from 6.46 to 6.79 mg/kg, respectively. In case of three-year-old ginseng, it was found to be from 4.18 to 4.35 mg/kg. As a result of annual pesticide residue analysis, concentration of the pesticide was found to decrease time-coursely in ginseng. This may be due to decomposition and increasing of fresh weight of the ginseng during the cultivation periods of three years.

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

Research on Science, Technology & Society in Korea: A Critical Review (과학기술과 사회 연구의 현황과 과제)

  • Bak, Hee-Je
    • Journal of Technology Innovation
    • /
    • v.25 no.3
    • /
    • pp.155-195
    • /
    • 2017
  • The goal of the present study is reviewing the literature on the scientific community and also on science, technology & society to increase interactions between innovation studies and social studies of science and technology. Up until now, various empirical studies on Korean scientists and engineers have been concentrated on researchers at universities, while they have paid inadequate attention to researchers at state-funded research institutes and private companies. In addition, these studies have tended to use concepts in Western academia to elucidate Korean cases. On the other hand, recent empirical researches on the effects of the evaluation systems in universities, PBS system, and the network of school ties suggest that these topics may reveal the unique characteristics of Korean scientific community. Empirical studies on the scientific community have also shown that Korean research institutes and researchers who are in charge of innovation in Korea have demonstrated a tendency to conform to the government's guidance due to long experiences of state-led R&D and nationalism. Research on science, technology and society has viewed the participation of citizens in science and technology as a way toward science and technology democracy, and tended to have a strong practical orientation. However, there has been a relatively small amount of research on how citizen participation influences the direction and content of technological innovation. Also, although, from the viewpoint of technological innovation, how participation of citizens in science and technology can contribute to knowledge production and innovation is a critical issue, relatively small numbers of case studies on this subject have been conducted. Therefore, as the scholars who have emphasized the democracy of science and technology have actually experimented with various ways of citizen participation, innovation researchers may have to design and implement citizen participation through which citizens' local knowledge can contribute to technological innovation.

Clinicopathological evaluation of Childhood Henoch-$Sch{\ddot{o}}nlein$ Purpura(HSP) Nephritis with Nephrotic Syndrome (신증후군을 동반한 Henoch-$Sch{\ddot{o}}nlein$ 신염 환아의 임상병리 적 고찰)

  • Kang Hyeon-Ho;Yoon Kyung-Leem;Cho Byoung-Soo
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.111-119
    • /
    • 2000
  • Purpose : Henoch-$Sch{\ddot{o}}nlein$ purpura(HSP) is a common pediatric discase presenting most frequently with skin, gastrointestinal, joint and renal manifestations. The prognosis of HSP is mainly determined by the involvement of the kidney, but prognostic markers have not been established. We evaluated the patients who have HSP nephritis with nephrotic syndrome. Method : Clinical manifestations and laboratory findings were observed and analyzed in 34 cases with HSP which were manifested by nephrotic syndrome hospitalized at Kyung Hee university Hospital during the period from Jan. 1990 to Dec. 1998. Results : 1) Male to female ratio was 1.3:1, and mean age at onset was 8.3 year. 2) Mean duration from symptom onset to renal biopsy was 10.5 weeks. 3) Proportion of patients presenting with acute nephritis was 32.4$\%$, gross hematuria 17.6$\%$, microscopic hematuria 50$\%$. 4) The findings of renal biopsy were 20 cases of grade II, 11 cases of grade III, 2 cases of grade I, 1 case of grade IV according to classification by ISKDC. 5) Patients with grade I were recovered with no residual defect, but patients with grade IV shows active renal disease(states C). Conclusion : Among the 디le patients with Henoch-$Sch{\ddot{o}}nlein$ purpura accompanying nephrotic syndrome, more aggressive treatment might be needed in patients showing crescents formation on renal biopsy. A prospective study will be needed to explore the progression of this disease.

  • PDF

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.

Birth and Infant Death Reporting System via Computer Network (출생 및 영아사망 신고체계 및 전산정보체계 개발)

  • Park, Jung-Han;Lee, Young-Sook;Rhee, Jung-Ae;Cho, Hyun;Chung, Young-Hae;Park, Soon-Woo;Jun, Hae-Ri
    • Health Policy and Management
    • /
    • v.8 no.2
    • /
    • pp.125-148
    • /
    • 1998
  • Accurate vital statistics are essential for a national health planning and evaluation. Among various vital statistics, birth and death rates, and infant and matemal mortality rates together with the causes of death are the very basic ones for above purposes as well as for the maternal and child health management. These statistics are based on the birth and death reports. It is required by law to report every birth and death within one month after its occurrence. However, in case of a neonatal death occurring prior to the birth report, most of the birth and death are not reported. Thus accurate infant and maternal mortality rates are not available yet in Korea. The main objective of this study is to develop a birth and infant death reporting system via computer network. We designed a new birth report form based on the current form and data from the analysis of medical record forms of 14 hospitals. A new form is basically addition of essential medical information to the current birth report form. Since a revision of the rules and regulations related wtih the birth report is necessary to use a new form, we kept the current from intact to make it acceptable to the government office for a field trial. We also developed computer programs for data input for birth and death reports at a medical faciltiy, data processing for production of maternal and child health indices at a health center, and management of maternal and child health services including immunization and postantal care at health center. The birth certificate and birth report can be printed out at a medical facility. The computer packages were programmed by Borland Delphi 3.0 and can be run under Windows 95 system. We proposed a new birth and death reporting system via computer network after a field trial for data input, transmission, and processing. The medical and demographic data o birth and death at medical facilities will be sent to health centers directly via computer network. The health center will retain the medical data for analysis and forward only the data for birth and death reports required by current regulations to the Dong, Up, or Myun Office. Once the birth or death is reported via computer network to the Dong Office, then the Dong Office will notify the baby's mother of the birth report and request to submit the baby's name by mail. When the baby's name its submitted. the Dong Office will forward the birth reports to the Common Court and Statistics Agency in the same way as the current system, Upon the completion of birth registration of the Common Court, the court will issue the birth certificate to mother which will be used in lieu of the family record. The advantages of proposed birth and death reporting system via computer network ar as follows ; I) The accuracy, timing, and completeness of reporting will be improved and more accurate maternal and child health indices can be obtained, ii) The maternal and child health services of health center will be obtained, iii) Epidemiologic data for pregnancy and birth can be obtained, iv) Manpower for birth and death reporting will be saved.

  • PDF

Anti-wrinkle Effect of Cambodian Phellinus linteus Extracts (캄보디안 상황버섯 추출물의 주름개선 효과 연구)

  • Cheon, Soon-Ju;Jang, Min-Jung;Jang, Young-Ah;Choi, Eun-Young;Jun, Dong-Ha;Kim, Young-Hun;Cho, Woo-A;Jeong, Yeon-Sook;Kwon, Hyeork-Bum;Kim, Tae-Hoon;Choi, Kyung-Im;Do, Jeong-Ryong;Lee, Chang-Eon;Lee, Jin-Tae
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1718-1721
    • /
    • 2008
  • The skin of human is constantly being exposed to environmental irritants such as ultraviolet, smoke and chemicals. These irritants cause free radicals and reactive oxygen species which leave serious damages on the cells of skin. The water and ethanol extracts of Cambodian Phellinus linteus were investigated for the activities of anti-lipid peroxidation and anti-wrinkle effects to apply as a functional ingredient for cosmetic products. As the result of evaluation of liquid oxidation rate by add $Fe^{2+}$ and $Cu^{2+}$ to Cambodian Phellinus linteus extracts, Cambodian Phellinus linteus ethanol extracts were higher than Cambodian Phellinus linteus water extracts in the chealting ability of $Fe^{2+}$ and $Cu^{2+}$. The Cambodian Phellinus linteus ethanol extracts exhibited that anti-lipid peroxidation higher than butylated hydroxytoluene (BHT) at the concentration of 0.1 mg/ml, 0.5 mg/ml and 1 mg/ml. Cambodian Phellinus linteus water and ethanol extracts showed a higher inhibitory effect on $Fe^{2+}$-induced lipid peroxidation compared to $Cu^{2+}$-induced lipid peroxidation. In the case of anti-wrinkle effect, the elastase inhibition activity of Cambodian Phellinus linteus ethanol extracts was 50.7%, and it is higher than urosolic acid at the concentration of 0.01 mg/ml. Also, in collagenase inhibition activity, Cambodian Phellinus linteus water extract showed low effect, but Cambodian Phellinus linteus ethanol extract was about 50% at a 0.1 mg/ml. concentration. These results proved that Cambodian Phellinus linteus had anti-lipid peroxidation and anti-wrinkle effect. Therefore, Cambodian Phellinus linteus could be useful as an anti-wrinkle cosmetic ingredient.