• Title/Summary/Keyword: evaluate a image

Search Result 2,298, Processing Time 0.034 seconds

Development of cardiopulmonary resuscitation nursing education program of web-based instruction (웹 기반의 심폐소생술 간호교육 프로그램 개발)

  • Sin, Hae-Won;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.25-39
    • /
    • 2002
  • The purpose of this study is to develop and evaluate a web-based instruction Program(WBI) to help nurses improving their knowledge and skill of cardiopulmonary resuscitation. Using the model of web-based instruction(WBI) program designed by Rhu(1999), this study was carried out during February-April 2002 in five different steps; analysis, design, data collection and reconstruction, programming and publishing, and evaluation. The results of the study were as follows; 1) The goal of this program was focused on improving accuracy of knowledge and skills of cardiopulmonary resuscitation. The program texts consists of the concepts and importances of cardiopulmonary resuscitation(CPR), basic life support(BLS), advanced cardiac life support(ACLS), treatment of CPR, nursing care after CPR treatment. And in the file making step, photographs, drawings and image files were collected and edited by web-editor(Namo), scanner and Adobe photoshop program. Then, the files were modified and posted on the web by file transfer protocol(FTP). Finally, the program was demonstrated and once again revised by the result, and then completed. 2) For the evaluation of the program, 36 nurses who in K university hospital located in D city, and related questionnaire were distributed to them as well. Higher scores were given by the nurses in its learning contents with $4.2{\pm}.67$, and in its structuring and interaction of the program with $4.0{\pm}.79$, and also in its satisfactory of the program with $4.2{\pm}.58$ respectively. In conclusion, if the contents of this WBI educational program upgrade further based upon analysis and applying of the results the program evaluation, it is considered as an effective tool to implement for continuing education as life-long educational system for nurse.

  • PDF

The Effects of Cyclooxygenase-2(COX-2) Inhibitor on COX-2 and Prostaglandin E2 Expression in Ovalbumin Induced Early Phase Bronchoconstriction of Rats (Ovalbumin으로 유발된 백서의 즉시형 기관지 수축 반응에서 Cyclooxygenase-2(COX-2) 발현 양상 및 혈중 프로스타글란딘 E2 농도와 COX-2 억제제의 효과)

  • Lee, Sung-Yong;Lee, Sin-Hyung;Jung, Ki-Hwan;Kim, Byung-Gyu;Jung, Hae-Chul;Kim, Kyung-Kyu;Kwon, Young-Hwan;Kim, Ja-Hyeong;Lee, Ju-Han;Lee, Sang-Youb;Cho, Jae-Yoen;Shim, Jae-Joeng;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.191-202
    • /
    • 2000
  • Background: Bronchial asthma is characterized by airway hyperresponsiveness(BHR) and inflammation. The cyclooxygenase(COX) is believed to be one of the important enzymes in these inflammatory reactions. Recently, the COX was divided into two isoforms, COX1 and COX2. COX2 is induced by lipopolysaccharide and some cytokines at the inflammation site. Prostaglandin E2(PGE2), produced from COX2, may affect airway inflammation. The purpose of this study is to evaluate the effect of COX2 inhibitor on COX2 expression, plasma PGE2, airway resistance and histologic finding in an animal asthma model. Methods : Sprague-Dawley rats were divided into 3 groups. The normal control group did not receive any treatment, but the asthma control group was sensitized by ovalbumin but not treated with the COX2 inhibitor(nimesulide, Mesulid$^{(R)}$). The treatment group was sensitized and treated with nimesulide. Specific airway resistance(sRaw) before and after nimesulide ingestion was investigated. The PGE2 level in the plasma was examined and COX2 immunogold-silver stain on lung tissue was performed. Results: sRaw and eosionophilic infiltration on airway, which increased in the asthma control group, was compared to normal control(p=0.014). However, there was no difference in eosinophilic infiltration between asthma control and treatment groups(p=0.408) and no difference in COX2 expression on bronchiolar epithelium among the three groups. Plasma PGE2 levels were not statically different among the three groups. Conclusion: The role of COX2 in the allergen-induced BHR was not significant The effect of nimesulide was not observed on BHR, COX2 expression, and plasma PGE2 level. Therefore, COX2 may not be a major substance of allergic asthma.

  • PDF

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Assessment of Viability in Regional Myocardium with Reversed Redistribution by Thallium Reinjection in Patients with Acute Myocardial Infarction (급성심근경색 환자에서 역재분포를 보인 심근의 Thallium 재주사에 의한 생존능의 평가)

  • Yoon, Seok-Nam;Park, Chan-H.;Pai, Moon-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 1998
  • Purpose: The aim of this study was to evaluate whether T1-201 reinjection distinguishes viable from non-viable myocardium in patients with reverse redistribution after acute myocardial infarction. Materials and Methods: We studied 42 patients with acute myocardial infarction (age, $55{\pm}12$ years). Eighteen (43%) out of 42 showed reverse redistribution on dipyridamole stress-4 hour redistribution T1-201 single photon emission computed tomography (SPECT). T1-201 reinjection was performed at 24 hours. Reverse redistribution was defined as worsening of perfusion defect at 4 hour delayed scan. All patients underwent follow-up echocardiography in 4 months to assess regional wall motion improvement. T1-201 uptake on reinjection images were analyzed for the prediction of myocardial wall motion improvement. Results: Of 36 segments with reverse redistribution, 17 segments showed normal wall motion on echocardiography, while 19 segments showed wall motion abnormalities. Of 19 the segments with reverse redistribution, 11 (58%) showed enhanced uptake after 24 hour reinjection. Myocardial wall motion was improved in 10 of 11 segments (90%) with enhanced uptake on reinjection. Wall motion improvement was not seen in 5 of 8 segments (63%) without enhanced thallium uptake. When myocardial viability was assessed by the uptake on reinjection image, nine of 10 segments (90%) with normal or mildly decreased uptake showed improved wall motion. Wall motion was not improved in 5 of 9 segments (16%) with severely decreased uptake. Conclusion: In patients with acute myocardial infarction, T1-201 reinjection imaging on myocardial segments with reverse redistribution has a high positive predictive value in the assessment of myocardial viability.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images (PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가)

  • Han, Dong Chan;Hong, Gun Chul;Choi, Choon ki;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of $^{18}F-FDG$. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.67{\pm}0.06g/mL$ and $0.65{\pm}0.06g/mL$, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.32{\pm}0.08g/mL$ and $0.56{\pm}0.12g/mL$, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

  • PDF

Differential Diagnosis of Bicornuate and Septate Uterus : Is Comparison of Septal Signal Intensity on MR Image Useful\ulcorner (양각 자궁과 중격 자궁의 감멸 진단: 자기공명영상에서 자궁 격막 신호 강도의 비교는 유용한가\ulcorner)

  • 김종철;변재영;백승연
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.107-112
    • /
    • 2000
  • Purpose : To evaluate the usefulness of comparison of the signal intensity of uterine septum in the differential diagnosis of bicornuate and septate uterus on magnetic resonance (MR) imaging. Materials and methods : Preoperative MR imaging findings of surgically proven 5 bicornuate and 6 septate uteri were retrospectively analyzed. Because preoperative differential diagnosis of both was possible in all cases in terms of the intercornual distance, external contour of uterine fungus, and divergent angle of two uterine cavities, these criteria were excluded in this study. The signal intensity of uterine septum in patients with bicornuate and septate uterus was analyzed on T1-weighted and fast spin echo T2-weighted images obtained in the axial and coronal planes, using a 1.5-T MR scanner. The signal intensity of uterine septum especially on T2-weighted images was compared with that of myometrium or junctional zone. Results : The signal intensity of uterine septum in patients with bicornuate uterus (n=5) and septate uterus (n=6) was similar to that of myometrium in all cases on T1-weighted images. The septum of bicornuate uterus (n=5) on fast spin echo T2-weighted images was isointense with myometrium in three and hypointense in two cases. The uterine septum of septate uterus (n=6) on T2-weighted images was isointense with myometrium in two, hypointense in two, and isointense with or more hypointense than junctional zone in two cases. No patient showed different signal intensity between upper and lower uterine septum. Conclusion : Because the MR signal intensity of the uterine septum in bicornuate or septate uterus is variable, it should not be used alone in the differential diagnosis of them. In these clinically important differentiation, therefore, comprehensive analysis of MR findings in terms of the external contour of uterine fundus, intercornual distance, divergent angle of two uterine cavities, in addition to the signal intensity of the uterine septum, should be considered.

  • PDF

High-Resolution Contrast-Enhanced 3D-Spoiled Gradient-Recalled Imaging for Evaluation of Intracranial Vertebral Artery and Posterior Inferior Cerebellar Artery in Lateral Medullary Infarction (고해상도 조영증강 삼차원 회손기울기 회상 영상을 이용한 측면연수경색 환자의 두개내 척추동맥 및 뒤아래소뇌동맥 평가)

  • Yoon, Youngno;Ahn, Sung Jun;Suh, Sang Hyun;Park, Ah Young;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • Purpose : To determine whether high-resolution contrast-enhanced three dimensional imaging with spoiled gradient-recalled sequence (HR-CE 3D-SPGR) plays a meaningful role in the assessment of intracranial vertebral artery (ICVA) and posterior inferior cerebellar artery (PICA) in lateral medullary infarction (LMI). Materials and Methods: Twenty-five patients confirmed with LMI were retrospectively enrolled with approval by the IRB of our institute, and 3T MRI with HR-CE 3D-SPGR and contrast-enhanced magnetic resonance angiography (CE-MRA) were performed. Two radiologists who were blinded to clinical information and other brain MR images including diffusion weighted image independently evaluated arterial lesions in ICVA and PICA. The demographic characteristics, the area of LMI and cerebellar involvement were analyzed and compared between patients with arterial lesion in ICVA only and patients with arterial lesions in both ICVA and PICA on HR-CE 3D-SPGR. Results: Twenty-two of twenty-five LMI patients had arterial lesions in ICVA or PICA on HR-CE 3D SPGR. However twelve arterial lesions in PICA were not shown on CE-MRA. Concurrent cerebellar involvement appeared more in LMI patients with arterial lesion in ICVA and PICA than those with arterial lesion in ICVA alone (p = 0.069). Conclusion: HR-CE 3D-SPGR can help evaluate arterial lesions in ICVA and PICA for LMI patients.

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF