• 제목/요약/키워드: evacuation stairs

검색결과 62건 처리시간 0.025초

The Simulation of a General Hospital Evacuation

  • Xiao-pei Liu;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.247-254
    • /
    • 2024
  • In this paper, we compare and analyze the evacuation time required at a general hospital using an evacuation simulation program and propose an optimized procedure to improve safety. The paper analyzed the evacuation time of all occupants, including patients who cannot evacuate by themselves. The following four cases were analyzed in order: the width of evacuation stairs is 120cm, 130cm, 140cm, and 150cm. The results of the evacuation simulation showed that the total evacuation time is 1998s, 1796s, 1651s, and 1161s, respectively. For every 10cm increase in the width of the evacuation stairs, the evacuation time decreases by 202s, 145s, and 91s in sequence. The evacuation time decreases as the width of the evacuation stairs increases. However, the rate of reduction in evacuation time decreases. Therefore, simply increasing the width of evacuation stairs cannot significantly improve evacuation efficiency, and it is necessary to choose an appropriate width of evacuation stairs. In addition, all four cases simulations display that after 600 seconds, the evacuees are concentrated in two evacuation stairs, while there are very few evacuees in the other stairs. To solve this problem, it is necessary to disperse the movement route and consider multiple avoidance methods.

대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구 (A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities)

  • 이정수;문재호
    • 교육시설
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

고층빌딩에서 옥외피난계단의 효용성에 관한 연구 (A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings)

  • 최규출
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.63-69
    • /
    • 2009
  • 건축법 시행령 제36조에는 3층 이상의 건축물로 문화 및 집회시설 중 공연장이나 위락시설로 바닥면적이 1천 $m^2$ 이상인 건축물은 옥외피난계단을 설치하도록 하고 있다. 도시의 인구집중화와 함께 고층빌딩의 증가는 인적재난에 대한 다양한 대비책을 요구하고 있다. 최근 10년 동안 고층빌딩 증가율은 85%로 급등하였다. 이러한 고층빌딩의 증가는 도시지역의 인적재난으로 이어져 화재발생 시 많은 인명피해와 재산피해를 동반한다. 고층빌딩에서 화재가 발생하였을 때 가장 어려운 소방활동이 피난활동이다. 상층으로 확산되는 연기 때문에 고층빌딩에서의 피난로 확보는 인명피해를 최소화 시키는 유일한 방법이다. 고층빌딩에서 직통계단이나 옥내계단으로는 피난로 확보가 어려워 고층빌딩 일수록 옥외피난계단이 필요하다. 옥외피난계단 설치에 관한 현행 법규는 너무 미미(微微)하여 고층빌딩의 피난로 확보대책으로는 적당치 못하다. 고층빌딩의 피난로 확보를 위하여 고층빌딩군(群)의 분류에 해당되는 10층 이상의 건축물에는 옥외피난계단 설치를 의무화하도록 관련법을 개정토록 하여야 한다.

축광재료를 부착한 계단의 피난유도에 관한 연구 (A Study about the Evacuation Guidance that Used Phosphorescent Material for Stairs)

  • 허만성;등전황홍;미등상
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.29-36
    • /
    • 2008
  • 본 연구는 화재시 연기발생 또는 정전이 발생한 경우 계단을 통해 안전하게 피난할 수 있도록 축광재료를 부착한 계단의 피난유도에 관하여 조사하였다. 실험조사는 설계 제작된 계단에 35명(1차 20명, 2차 15명)의 학생이 참여하여 계단의 시인성(visibility), 오르내림의 편리성과 안심감에 대하여 실험을 실시하였다. 실험 조사결과 축광재료를 사용한 계단코는 정전시에도 계단의 단 높이 확인이 가능하여 계단 오르내릴 때 편리하고 안심할 수 있기 때문에 어두운 곳에서 사람이 피난 행동할 때에 매우 효과적이었다. 따라서 계단코와 계단참에 축광재료를 설치하면 정전이 되더라도 평소와 다름없이 피난을 할 수 있을 것으로 판단된다.

실규모 수리모형실험을 이용한 계단 흐름에서의 안전성에 관한 연구 (A Study on Safety at Stairs Flow using the Real-scale Hydraulic Model Experiment)

  • 김명환;이두한
    • Ecology and Resilient Infrastructure
    • /
    • 제5권4호
    • /
    • pp.210-218
    • /
    • 2018
  • 본 연구에서는 침수된 계단 흐름의 변화에 따른 인명의 대피 안전성을 분석하기 위하여 실규모의 계단 수로 모형을 제작하여 수리 실험을 수행하였다. 실험에서는 계단 각각의 단에서의 수심과 유속을 측정하였으며 이를 이용하여 단위 폭당 비력을 산출하였다. 그리고 산출된 단위 폭당 비력 값을 이용하여 침수된 계단 흐름의 변화에 따른 구간별 대피 안전성을 제시하였다. 실험을 통해 측정된 수심 값과 Ishigaki의 단위 폭당 비력에 따른 대피 안전성 그래프를 결합하여 분석한 결과 계단 흐름 수심 0.20 m 이상에서는 도움 없이 성인 남성의 대피가 어려운 것이 확인되었으며, 수심 0.15 m 이상에서는 성인 여성과 노인 남성이 도움 없이 대피가 어려운 것으로 확인되었다. 노인 여성의 경우 수심 0.13 m 이상에서 도움 없이 대피가 어려운 것으로 나타났다.

고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구 (A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State)

  • 김진호;양정훈;석호태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

VR기법을 활용한 엘리베이터 피난 성능평가에 관한 연구 (Study for Using VR Techniques Performance Evaluation of the Elevator Evacuation)

  • 노세호;윤성욱;이동호
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.13-18
    • /
    • 2011
  • 방재설계를 하는데 있어서 피난의 주체인 재실자가 화재시 신속하고 안전하게 피난 가능 하도록 피난방법의 최적으로 정립하는 것이 핵심적 사항이다. 건설 기술의 발전으로 많은 초고층 건축물이 세워지고, 초고층 건축물은 다양한 위험을 내포하고 있으며 재해의 정도를 증대시키고 있다. 초고층 건축물의 기본 설계 단계에서, 화재시 재실자가 피난 계단과 엘리베이터를 동시에 시용하여 피난하는 것을 고려 할 수 있으나, 이러한 피난 계단과 엘리베이터를 동시에 이용안 대피 성능 평가는 적립되어 있지 않다. 본 연구에서는 Virtools를 이용한 VR 기법을 사용하여 화재시 재실자가 비상 엘리베이터 및 피난계단을 동시에 이용하여 피난 할 경우에 대한 대피성능평가를 시뮬레이션을 통하여 분석하였다.

Simulation Analysis of Safety Evacuation in University Experiment Building

  • Tao Zhang;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.218-226
    • /
    • 2024
  • According to the actual situation of a university, the emergency evacuation simulation is modeled based on the physical sign, evacuation speed and personnel ratio using the pathfinder software.The experimental construction export utilization rate is compared with the preliminary simulation scenario. The simulation results show that the utilization rate of evacuation stairs and evacuation exits is significantly improved.The optimized solution can provide the most effective evacuation passage, and the research results can provide the basis for the rational planning and management of evacuation passage in university experiment building.

피난계단 출입구 유효너비가 수용인원의 피난시간에 미치는 영향 분석 (Analysis of the Effect of the Effective width of the Exit of the Evacuation Stairs on the Evacuation Time of the Occupants)

  • 양성훈
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.73-79
    • /
    • 2022
  • 연구목적: 건축법에 따라 설치되는 피난계단 출입구의 최소 유효 폭(90cm) 기준이 해당 층을 사용하는 전체 재실자의 피난 시간과는 어떤 관계가 있는지 피난 관점에서 알아보고자 하였다. 연구방법: 출입구 폭의 변화에 따라 재실자의 피난 시간에 어떠한 영향을 미치는지를 피난 시뮬레이션(Pathfinder)을 통하여 알아보았다. 연구결과: 출입구의 유효 폭이 최소기준 90cm보다 커지면 커질수록 피난계단으로의 피난 시간이 단축되는 것을 알 수 있었고, 더불어 출입구의 너비가 일정 크기 이상 되면 피난 시간은 더는 단축되지 않는다는 사실도 알 수 있었다. 이는 해당 층 전체 재실자의 수에 따라 피난계단 출입구의 유효 너비를 적정하게 달리 적용할 수 있다는 방증(傍證)이기도 한 것이다. 결론: 앞으로는 재실자의 피난 안전성 확보를 위해 용도별 전체 수용인원을 고려한 피난 계단 출입구 유효 폭 기준이 필요할 것으로 판단된다. 더불어 연구 및 실험을 통해 용도별 수용인원에 따른 다양한 출입구 유효 폭 기준이 만들어진다면 재실자의 피난 효율성이 크게 증대될 수 있을 것으로 기대된다.

노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구 (A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital)

  • 김미정;권지훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권1호
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.