• Title/Summary/Keyword: evacuation safety assessment

Search Result 71, Processing Time 0.022 seconds

A Study on the Strength Properties of FRP Member for Making Personal Disaster Shelters in Rural Area (농산촌 재난대피시설 제작을 위한 FRP 부재의 강도특성에 관한 연구)

  • Kim, Jung Meyon;Hwang, Dea Won;Lim, Hyun Taek;Park, Sung Yong;Yeon, Kyu Seok;Kim, Yong Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.73-82
    • /
    • 2016
  • This study is about development of personal disaster shelters for minimization of the casualties caused by the landslide and steep slope collapse. The objectives of present research is the selection of disaster evacuation facilities utilizing FRP (Fiber Reinforced Plastic) material. For the proper assessment of FRP member, several layers by strength test and the three-dimensional numerical analysis of these FRR member was carried out. As a result, the personal disaster evacuation facility utilizing FRP materials, was found to be of a material that is able to protect the weak person at the time of the collapse of the landslides and steep slopes.

The study on interval calculation of cross passage in undersea tunnel by quantitative risk assesment method (해저철도터널(목포-제주간) 화재시 정량적 위험도 평가기법에 의한 피난연결통로 적정간격산정에 관한 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Quantitative Mokpo-Jeju undersea tunnel is currently on the basis plan for reviewing validation. As for the cross section shape for express boat of 105 km line, sing track two tube is being reviewed as the Euro tunnel equipped with service tunnel. Also, 10 carriage trains have been planned to operate 76 times for one way a day. So, in this study, quantitative risk assessment method is settled, which is intended to review the optimal space between evacuation connection hall of tunnel by quantitative risk analysis method. In addition to this, optimal evacuation connection hall space is calculated by the types of cross section, which are Type 3 (double track single tube), Type 1 (sing track two tube), and Type 2 (separating double track on tube with partition). As a result, cross section of Type 2 is most efficient for securing evacuation safety, and the evacuation connection space is required for 350 m in Type 1, 400 m in Type 2, and 1,500 m in Type3 to satisfy current domestic social risk assessment standard.

A study on quantitative risk assessment for railway Tunnel fire (철도터널에서 차량화재시 정량적 위험도 평가에 관한 연구)

  • Yoo, Ji-Oh;Nam, Chang-Ho;Jo, Hyeong-Je;Kim, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2010
  • As we learned in Daegu subway fire accident, fire in the railway tunnel is prone to develop to large disaster due to the limitation of smoke control and smoke exhaust. In railway tunnel, in order to ensure fire safety, fire prevention and fighting systems are installed by quantitative risk assessment results. Therefore, in this research, developed the program to establish quantitative risk assessment and suggested quantitative safety assessment method including fire scenarios in railway tunnel, fire and evacuation analysis model, fatality estimate model and societal risk criteria. Moreover, this method applys to plan preventing disaster for Honam high speed railway tunnel. As results, we presented the proper distance of escape route and societal risk criteria.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

A Study on the Safety Measures for Typhoon Shelter in Jinhae Bay Based on AHP Assessment (AHP 기법 기반 진해만 태풍 피항지 내 안전대책에 관한 연구)

  • Kim, Ni-Eun;Lee, Myoung-Ki;Camliyurt, Gokhan;Park, Do-Hyeong;Kim, Dae-Won;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.507-514
    • /
    • 2022
  • Jinhae Bay is used as a major typhoon shelter in the southeastern region of Korea. However, when a typhoon strikes, the Jinhae Bay is facing the possibility of marine accidents caused by dragging anchors and the increased number of ships. This paper suggested ways to safely and efficiently manage the port of Jinhae Bay when a typhoon strikes from Vessel traffic service operators in the sea, derived relative importance by conducting an Analytic Hierarchy Process assessment to ship operators, and suggested safety measures reflecting manager and user opinions. In order to select safety measures factors for the AHP survey, VTS operators analyzed the evaluation of measures when a typhoon strikes in Jinhae Bay. As a result of conducting a survey based on the selected safety measure factors, it was found that ship operators consider the safety of ships more than twice as important as efficient management, and comprehensively consider them in the order of management of evacuated ships, management of anchorage area, management of evacuation information, preparation regulations and guidelines, improvement of system equipment, education, publicity, and notification activities. Through the measures and relative importance identified in this paper, it is believed that Jinhae Bay can serve as the basis for safely and efficiently managing typhoon shelters.

A Study on the Evacuation Safety Assessment according to Installation Conditions of Variable Message Sign inside a Tunnel (터널 내 정보표지판 설치조건에 따른 대피 안전성 평가)

  • Lee, Su-Kyung;Song, Dong-Woo;Joo, Tae-Young;Kim, Ki-Sung;Bak, Woo-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.428-431
    • /
    • 2012
  • 본 연구에서는 터널 화재 시 보다나은 대피 안전성확보를 위해 2차적 사고예방에 목적을 둔 정보표지판(Variable Message Sign)을 제연막으로 활용함으로써 터널 대피자의 안전성을 확보하고 대피취약자로 하여금 충분한 대피시간의 확보를 위한 최적의 조건을 제시하고자 하였다. 정보표지판의 다양한 설치 조건에 따라 화재연기가 전파되어지는 거리를 화재 시뮬레이션인 FLUENT와 피난 시뮬레이션인 SIMULEX를 이용하여 통근자와 고령자의 안전거리를 비교하고 대피 안전성을 검토하였다.

  • PDF

A Study on Safety Assessment of the Evacuation at Underground Tunnel of the Light Rail Transits (경량전철 지하터널의 피난안전성능 평가에 관한 연구)

  • Ko, Kwang-Hoon;Lee, Su-Jyung;Song, Dong-Woo;Kim, Tae-Hoon;Kim, Ki-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.541-544
    • /
    • 2011
  • 경량전철시스템은 운전자가 없는 무인으로 운행하며 각종 설비가 자동으로 제어되도록 되어있기 때문에 일상적인 고장이나 문제는 어느 정도 안전대책이 마련되겠지만 테러 또는 고의에 의해 일어나는 사고는 대비하기가 어려운 실정이다. 정거장에서의 화재발생은 많은 보고서와 기준들이 정리되어 있으나 지하 터널이 본선 구간에서의 피난을 위한 시설의 적정성 및 피난시간에 대한 연구는 부족하다. 본 연구에서 경량전철 시스템의 운전 중에 지하터널에서 발생 가능한 사고시나리오를 고려하여 화재시뮬레이션 및 피난시뮬레이션을 실시하여 비교하고, 그 결과에 따라 대안을 도출하였다.

  • PDF

A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment (정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구)

  • Lee, Bo-Hoon;Hong, Seo-Hee;Baek, Doo-San;Lee, Ho-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.539-552
    • /
    • 2022
  • In the case of train stations, due to the specificity of underground spaces with limited smoke emissions, if appropriate removal equipment is not equipped, the damage caused by fire smoke may increase in the event of a fire. As a result, the need for measures to ensure the safety of evacuation of underground stations has been highlighted, and research for safe evacuation of platform users in case of fire is continuously being conducted at home and abroad. However, although the smoke removal area is currently divided by smoke boundary walls and platform screen doors (PSD) and installed in the train platform, standards for smoke removal methods (air supply or exhaust) for each fire removal area, that is, smoke removal mode, are not presented. In this study, fire analysis and evacuation analysis were performed to estimate the number of deaths and to derive F/N guidance in order to quantitatively evaluate the fire risk according to the fire station fire, and the total risk was the lowest in the case of fire area exhaust and supply to adjacent areas.

A Numerical Study of Building Orientation Effects on Evacuation Standard in Case of Toxic Gas Leakage (독성 가스 누출 시 건물 방향이 대피 기준에 미치는 영향에 관한 수치 해석 연구)

  • Seungbum Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.12-18
    • /
    • 2023
  • The effective evacuation strategy according to the accident scenario is crucial to minimize human casualties in the event of toxic gas leak accidents. In this study, the effect of the direction of a building and the location of an industrial complex on the increase in indoor concentration and outdoor diffusion was examined under the same leakage conditions, and effective evacuation criteria were established. In addition, the guidelines for building directions were suggested when constructing buildings that would mitigate human damage caused by chemical accidents. Three scenarios where buildings faced the front, side, and rear of the leakage direction were investigated through CFD simulations. The results revealed that when the building faced the industrial complex, both indoor and outdoor average gas concentrations increased significantly, reaching up to 120 times higher than the other two orientations. Moreover, the indoor space was filled with toxic gas substances more than twice in the same time due to the rapid increase of indoor concentration rate. In cases where the building's windows were positioned at the front, toxic gas stagnation occurred around the building due to pressure differences and reduced flow velocities. Based on our findings, the implementation of these guidelines will contribute to safeguarding residents by minimizing exposure to toxic gas during chemical accidents.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.