• 제목/요약/키워드: evacuation facilities

검색결과 218건 처리시간 0.028초

폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구 (A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities)

  • 이재영;전용한
    • 대한안전경영과학회지
    • /
    • 제23권1호
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

철도터널 화재에 대한 정량적 위험도 분석 (Quantitative Risk Analysis for Railway Tunnels)

  • 박정현;심차상
    • 한국철도학회논문집
    • /
    • 제20권3호
    • /
    • pp.400-412
    • /
    • 2017
  • 국내외 철도터널 방재기준들에서 특히 주목할 만한 것은 신속한 대피를 위해 많은 비용이 소요되는 대피통로 설치 기준을 강화 적용하고 있다는 점인데, 국내 기준의 경우 1km 이상 연장의 터널별 QRA 분석을 통해 위험수준에 따라 설치여부를 결정하도록 하고 있으나, QRA 분석에 필요한 화재발생확률, 화재발생 시나리오, 화재규모, 사회적 위험도 평가기준 등에 대한 세부적용기준들이 정립되어 있지 않음으로써 과다설계로 인한 사회적 추가비용이 발생할 수도 있으므로 이에 대한 적정 수준의 기준 정립이 필요하다. 이에 본 연구에서는 관련문헌 조사 분석을 통해 합리적이고 적정한 수준의 세부적용조건들을 선정하여 서로 다른 터널연장을 가진 모델 터널(고속철도용)들에 대한 QRA 분석과 동시에, 중요 대피촉진시설중 하나인 대피통로 미적용 가능한 터널최대연장에 대해 분석하였다. 또한, 현재 호남고속철도 등 터널들에 대한 QRA 결과와 모델 터널의 분석결과를 종합, 피난촉진시설 관련 국내외 기준들과의 비교를 통해 적용기준의 적정성 검토를 수행하였다. 이들 결과들은 향후 안전성과 경제성이 고려된 합리적인 방재계획 수립을 위한 기초자료로써 활용될 수 있을 것으로 기대한다.

노인전문요양시설의 동선에 관한 연구 (A Study on the Current Situation about the Path of Flow in the Care Facilities)

  • 추연철;이동숙;윤충열
    • 한국농촌건축학회논문집
    • /
    • 제10권4호
    • /
    • pp.9-16
    • /
    • 2008
  • The purpose of this study is to compare and seize the type of the path of flow for nurses and living assistant, of the path of flow for evacuation and walking practice by analysis plan for the care facilities in the out-of-home service. It supposed many problem for living in the care facilities for the aged get down activity, especially their relates with difficulty in walking. And services of nurses and living assistant get mixed properties by that problem for the aged with difficulty in walking. It classified into T type, L type, H type, ${\Box}$ type, - type all the path of flow for nurses and living assistant on the longest from nursing station to each bedroom, the path of flow for evacuation from each room to exit, the path of flow for walking practice on the corridor and lobby. The three path of flow are influenced by an inner court, especially passable court is the important primary factor in the communication between the aged, a course and time required of flow.

  • PDF

지역문화시설의 지체장애인 동선계획에 관한 연구 - 광주지역 문화시설을 중심으로 - (A Study on Circulation planning of the disabled in Local Cultural arts center)

  • 이수용;박동준;오세규
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2005
  • The disabled has remarkable difficulties to participate social activities and those, that block them up from access to public facilities and the comfortable habitation so they should get help from others, are mainly made by architectural facts. Buildings without impediment which consider the disabled would be the things responding to the needs of the times. If the disabled would be convenient to use facilities, there should be no difficulties to normal people. A first began to examine into the role of the architecture. And to establish radical standards for the disabled to use cultural and assembly facilities through scrutinizing facilities to get access for the disabled and movement circulations in the cultural facilities should be the conclusion. This study which is a kind of fundamental study to construct cultural facilities without obstacles for the disabled began from consideration for the problem flow line of the disabled in cultural facilities and analyzed flow lines for them to use, access, and evacuate from those which are main facilities in the region. Though, evacuation rules in cultural and assembly facilities are recommendatory in existing laws for convenience of the disabled, the congestion of the crowd coming out after performances impedes safe flows of both the disabled and crowds. Further, in case of evacuation, there would be more serious problems. Therefore, consideration of reinforcement for existing laws for convenience of the disabled is needed.

  • PDF

화재 시 재실자 행동의 상호 작용을 고려한 건물 피난 행태 분석 (Analysis of Building Emergency Evacuation Process with Interactions in Human Behaviors)

  • 최민지;박문서;이현수;황성주
    • 한국건설관리학회논문집
    • /
    • 제14권6호
    • /
    • pp.49-60
    • /
    • 2013
  • 건축물에 있어 피난 계획은 프로젝트 전반에 걸쳐 고려되어야 할 매우 중요한 요소 중 하나이다. 기존 다양한 연구 및 실제 재난 사례등을 통해 피난의 중요성은 지속적으로 강조되어 왔으며, 사전 대비를 위한 다양한 노력들이 수행되어 왔다. 또한, 실제와 유사한 대응 훈련 준비의 어려움을 극복하고자 시뮬레이션을 통한 해결책 마련이 새로운 대안으로 떠올랐다. 그러나 피난 계획의 경우 시설물 뿐만 아니라 재실자의 특성 또한 신중히 고려되어야 한다. 현실과 가까운 피난 계획의 수립을 위해 본 연구에서는 인간 행태를 고려한 피난 과정을 분석한다. 기존 사회과학 이론에 기초하고 시스템 다이내믹스 모델링을 이용하여, 피난 초기부터 탈출까지 다양한 재실자 그룹의 특성으로 인해 발생하는 요인들을 포함하며, 이에 따른 의사결정, 행동의 변화 등의 분석한다. 이러한 모델을 통해 그룹 형성 및 재실자 간 상호 작용 등 긴급 상황에서 발생하는 인간 행태가 전체 피난 행태 및 결과에 미치는 영향을 파악하며, 향후 피난 시뮬레이터의 모듈로써의 활용 및 시설물 안전 관리자의 피난 계획 수립 시 의사결정의 기초자료를 제공할 것이라 예상된다.

홍수재난에 대한 최적 대피경로 분석 (Analysis of Optimal Evacuation Route for Flood Disaster)

  • 김경훈;박재우
    • 한국콘텐츠학회논문지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2018
  • 가뭄, 홍수 등의 자연재난으로 인해 인명 손실이 많이 발생되고 있다. 특히 도시지역에 발생되는 집중호우로 인한 침수 피해는 인명 및 구조물에 심각한 피해를 발생시킨다. 이에 따라 본 연구에서는 침수피해가 높은 도시지역을 대상으로 사람들이 안전하게 대피할 수 있도록 하는 최적 대피경로에 관한 연구를 수행하였다. 이를 위해 Flo-2D 모형 및 A*알고리즘에 대하여 고찰하여 최적 대피경로를 도출하고자 하는 방법론을 설정하였다. Flo-2D모형을 통해 위험지역을 도출하였으며, 인원수가 많은 시작지점을 선정하고 홍수재난에 대해 안전한 대피지점을 선정할 수 있도록 하는 방법을 제시하였다. 그리고 A* 알고리즘을 활용하여 출발지점에서 안전한 대피지점까지 위험지점을 거치지 않고 최적의 대피경로를 도출하였다. 본 연구를 통해 대피경로 제시뿐만 아니라 도로정비와 대피시설물에 대한 사전 대비 자료로 활용될 수 있을 것으로 판단된다.

다중이용시설의 피난방화문에 관한 연구 (Study of evacuation fire doors in multiple facilities)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7380-7384
    • /
    • 2014
  • 피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

장애인복지관 화재 시 피난안전성 분석 (Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled)

  • 박선아;이재영
    • 한국융합학회논문지
    • /
    • 제12권12호
    • /
    • pp.315-322
    • /
    • 2021
  • 이 연구는 장애인복지관 화재 시 이용자들의 층별 배치에 따른 비상 통로를 이용한 RSET(Required Safe Egress Time, 피난소요시간)을 분석하여 안전성을 평가하고, 효율적인 피난 방법을 제시하고자 패스파인더 시뮬레이션 프로그램을 활용하여 비상 통로별 RSET의 차이를 분석하였다. RSET에 따른 결과로, 현재 상태의 시설물 사용 인원 배치는 화재 시 기준 RSET을 만족시킴으로 피난안전성에 문제가 없다는 결과를 얻었으며, 화재 시 가능하면 승강기를 이용하는 것보다 계단을 통하여 피난해야 안전하게 피난을 완료할 수 있다. 직원들은 화재 시 장애인들을 대동하여 효과적으로 피난할 수 있도록 사전에 충분한 교육과 훈련이 필요하다. 본 연구는 장애인 관련 시설에서 설계·건축단계에서 운영까지 장애인들이 화재 시 안전하게 피난할 수 있도록 피난통로를 확보하고, 정기적인 피난훈련으로 RSET을 단축시킴으로써 안전하게 피난하여 소중한 생명을 지킬 수 있다는데 의의를 둔다. 향후에는 시설물의 각 층 출입구에 자동방화문을 설치함으로써 특정 위치에서 화재 발생 시 자동방화문의 개폐 여부에 따른 RSET의 연구가 필요하다.

클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안 (Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation)

  • 최준호;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 2015
  • 건물 내 필수적인 이동수단으로 사용되는 승강기는 비상상황 시, 탈출수단으로 이용될 경우 기대효과가 높기 때문에 많은 연구가 진행되고 있다. 서울특별시 초고층 건축물 가이드라인에서 층수는 지하 7층, 지상 53층, 바닥면적 $6,800m^2$ 연면적 $127,050m^2$, 용도는 문화 및 집회시설 판매시설 업무시설 숙박시설(호텔) 공동주택(아파트)의 건축물을 설계하면서 피난용승강기를 별도로 설치하기에는 효율적이지 못하다는 판단 하에 승용승강기의 설치기준에 따라 설계된 승강기를 피난용으로 사용하기로 결정하였으나 이에 대한 세부 설계지침내용이 아직까지 마련되어 있지 않아[1] 화재 시 공기주입, 스프링클러 가동, 스마트폰연동 탈출 가능한 클라우드 기반 피난유도 승강기시스템을 제안하였다.