• Title/Summary/Keyword: evacuation environment

Search Result 132, Processing Time 0.025 seconds

Analysis of Fire Evacuation Behavior in a Primary School Environment

  • Lee, Chang-Seop;Kim, Hong;A. Kilpatrick;W. Fitzpatrick
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.492-504
    • /
    • 1997
  • The paper compares the statutory requirements for the design mid construction of primary schools in Korea and Scotland with respect to fire safety and examines the attitudes to, and the behavior in, evacuation scenarios of Primary school Pupils in both countries. The key behavioral issues examined are the effectiveness of fire safety training, the level of teacher dependency, the effect of spatial organization and gender differences both within and between Korea and Scotland.

  • PDF

Estimation of the Relative Risk of the Elderly with Different Evacuation Velocity in a Toxic Gas Leakage Accident (독성물질 누출 시 대피 속도 차이에 따른 고령자의 상대적 위험도 산정)

  • Lee, H.T.;Kwak, J.;Park, J.;Ryu, J.;Lee, J.;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.13-21
    • /
    • 2019
  • Leakage accidents in businesses dealing with hazardous chemicals can have a great impact on the workers inside the workplace, as well as residents outside the workplace. In fact, there were cases where hazardous chemicals leaked from many businesses. As a result, the Chemicals Control Act(CCA) was enacted in 2015, the Ministry of Environment introduced an Off-site Risk Assessment(ORA). The purpose of the ORA is to secure safety from the installation of the design of the workplace facilities so that chemical accidents of hazardous chemical handling facilities do not cause human or physical damage outside the workplace. In general, the ORA qualitatively determines where a protected facility is within the scope of the accident scenario. However, elderly who belong to the sensitive group is more sensitive than the general group under the same chemical accident effect, and the extent of the damage is serious. According to data from the Korea National Statistic Office, the number of elderly people is expected to increase steadily. Therefore, a quantitative risk analysis considering the elderly is necessary as a result of a chemical accident. In this study, accident scenarios for 14 locations were set up to perform emergency evacuation due to toxic gas leakage of Cl2(Chlorine) and HF(Hydrogen Fluoride), and the effects of exposure were analyzed based on the evacuation velocity difference of age 20s and 60s. The ALOHA(Areal Locations of Hazardous Atmospheres) program was used to calculate the concentration for assessing the effects. The time of exposure to toxic gas was calculated based on the time it took for the evacuation to run from the start point to the desired point and a methodology was devised that could be applied to the risk calculation. As a result of the study, the relative risk of the elderly, the sensitive group, needs to be determined.

A Study on pollution of spring in Incheon Area (인천 지역 약수터의 오염에 대한 연구)

  • Kim, Kyung-Ae;Lee, Byeng-Ok;Kim, Ou-Mok;Hur, Myung-Je;Kim, Kyung-Tae;Ro, Jae-Il;Choe, Choon-Suck;Go, Jong-Myoung;Kim, Yong-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.35-50
    • /
    • 2007
  • In order to investigate water pollution of spring, we carried out the experiments on mineral water, rainwater and surrounding soil of several springs collected in Incheon area from February to August in 2007. The results were as follows. 1. Soil : This study investigated the pH and organic matter contents in the soil which effect on microorganisms. The pH value was from 4.5 to 5.3 on average and organic matter contents ranged from 1.09% to 5.6% and E. coli, K. pneumoniae, S. faecalis and other microorganisms were isolated. 2. Natural mineral water : As the rainfall increased, the concentration of $No_3-N$, consumption of $KMnO_4$ and the number of microorganisms was increased while the other physicochemical items were not affected. The microorganism isolated in the natural mineral water were as follows: E. coli, K. oxytoca S. faecalis, S. facium, and so on from evacuation; E. agglomerans, E. amnigenus, E. cloacae, E. sakazakii and so on from the environments and evacuation. Detection of these microorganisms shows that the environment around the spring had been exposed to excrements of the warm blood animal. 3. Rain : The coliforms in the rain were the identical one detected from the mineral water and the soil. In conclusion the quality of natural mineral water is influenced by rain, resident bacteria of soil and surrounding environment. This study will be the basic data of characteristics of spring in Incheon area and also this result will give useful aids for the efficient control of spring.

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

Rapid construction delivery of COVID-19 special hospital: Case study on Wuhan Huoshenshan hospital

  • Wang, Chen;Yu, Liangcheng;Kassem, Mukhtar A.;Li, Heng;Wang, Ziming
    • Advances in Computational Design
    • /
    • v.7 no.4
    • /
    • pp.345-369
    • /
    • 2022
  • Infectious disease emergency hospitals are usually temporarily built during the pneumonia epidemic with higher requirements regarding diagnosis and treatment efficiency, hygiene and safety, and infection control.This study aims to identify how the Building Information Modeling (BIM) + Industrialized Building System (IBS) approach could rapidly deliver an infectious disease hospital and develop site epidemic spreading algorithms. Coronavirus-19 pneumonia construction site spreading algorithm model mind map and block diagram of the construction site epidemic spreading algorithm model were developed. BIM+IBS approach could maximize the repetition of reinforced components and reduce the number of particular components. Huoshenshan Hospital adopted IBS and BIM in the construction, which reduced the workload of on-site operations and avoided later rectification. BIM+IBS integrated information on building materials, building planning, building participants, and construction machinery, and realized construction visualization control and parametric design. The delivery of Huoshenshan Hospital was during the most critical period of the Coronavirus-19 pneumonia epidemic. The development of a construction site epidemic spreading algorithm provided theoretical and numerical support for prevention. The agent-based analysis on hospital evacuation observed "arched" congestion formed at the evacuation exit, indicating behavioral blindness caused by fear in emergencies.

Study on the Application Possibility of Heating-cooling system with Smoke ventilation duct to Standard Apartment (공동주택의 제연겸용 덕트형 냉난방 공급시스템의 적용가능성에 관한 연구)

  • Chun, Jung-Gil;Park, Jung-Han;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.468-473
    • /
    • 2008
  • Currently, most of the buildings have been the high-rise buildings and not only the damage for people but also loose of property have been increased significantly. Furthermore, the damage for residents in indoor is increased significantly, the law related to fire protection is not established yet. We discussed safety of evacuation according to unitary system in standard apartment. At a result, when installing the smoke ventilation system, the RSET has been achieved and delay effect for reaching time of CO and smoke area has been obtained.

  • PDF

Analysis Report of the Elapse for Costa Concordia's Disaster (코스타 콘코디아 재난 경과 분석 보고서)

  • Yoon, Dae-Gwun;Kim, Cheol-Seung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.331-335
    • /
    • 2012
  • On January 13th 2012 Italian flag Costa Concordia was partly sunk. The ship was carrying 4,252 passengers and crew; in the next few days the bodies of 30 people were found. Two are still missing. Two South Korean passengers and an Italian crew member was rescued from the ship on January 15th, more than 24 hours after the accident. As of June 18th 2012 (The date of presentation) around 32 people had not been accounted for. In this paper, it is viewed and pointed out the cause, problem, and implication for the future. As a result, intelligent innovative evacuation system for the VLPS (Very Large Passenger Ship) should be set up in terms of international maritime safety.

A Study on the Safety Assessment of Water-based Firefighting Training Center using Fire Dynamics Simulation (FDS를 활용한 수소화 훈련장 안전성 평가에 관한 연구)

  • Doyoeng Park;Junho Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2024
  • According to the section A-VI/3 of the International Convention on Standards of Training, Certification and Watchkeeping for Seafarers (STCW), Water-based firefighting training center is mandatory to obtain onboard certificates. This space, being similar to fire situations on ships requires that safety measures be quantified to ensure occupant safety and establish operational standards. For fire safety evaluation, cases were designed based on the presence or absence of smoke control equipment using Pyrosim based on Fire Dynamics Simulation (FDS). Vector analysis was performed to evaluate flow of smoke and heat. Available safe escape time / required safe escpae time (ASET/RSET) analysis was conducted to evaluate safety by comparing the interpreted numerical results through Pathfinder. During safety evaluation of the current operational condition, the appropriateness of the function of each smoke control equipment was numerically and visually indicated. The emergency situation with dust collector stopped was expressed by each evacuation time and safety margin of 111.2 seconds, suggesting that be used as a standard of evacuation time.

Indoor Environment Monitoring System Using Short-range Wireless Communication in Mobile Devices (휴대용 단말기의 근거리 무선통신을 이용한 실내 환경모니터링 시스템)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2167-2173
    • /
    • 2013
  • Recently, people are paying huge attention to problems caused by indoor air pollution. Also, the need for the system that monitors environmental information for indoor and warns a danger is growing increasingly. In this regard, we designed and implemented environment monitoring system for indoor. In this paper, we describe the system with hardware elements and it's communication method. In order to transfer the data from environment sensors, we use short-range wireless communication in smart phone. The proposed system is possible to know the indoor environment information in installed sensor node. If the risk is found, For the proposed system, there is an advantage that may be appropriate evacuation.