• Title/Summary/Keyword: evacuation

Search Result 1,413, Processing Time 0.027 seconds

A Study on the Evacuation Performance of Evacuation System using Real-time IoT Information (실시간 IoT 정보 활용 피난시스템의 피난성능 연구)

  • Lee, Chul Gyoo;Moon, Sang Ho;Lee, Sang Kyu;Lee, Gye Eun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.281-291
    • /
    • 2019
  • In order to reflect complex and diverse building types, resident characteristics and disaster factors, it is necessary to introduce a flexible situation-based response system based on real-time information. Intelligent CCTV, hybrid sensor, location scanner, and customized broadcasting device were examined to introduce for the real-time response intelligent response system and its feasibility was verified through field test. In addition, based on the real-time information, the evacuation simulation was executed by assuming the dormitory building and the resident of the school, and the safety of the evacuation and the shortening of the pinnacle time were confirmed. The feasibility of real time information based evacuation comparing with the existing evacuation system were verified in the case of evacuation.

A Study on Securing Safety for High Rise Building Fires - Applying Active Fire Escape Systems -

  • Myung Sik, Lee;Sung Jae, Han
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.227-240
    • /
    • 2022
  • Under the Korean Enforcement Decree of the Building Act, all high story apartment houses more than 5 stories high are mandated to install a fire evacuation system to ensure safe evacuation from fire accidents and providing quick and easy bidirectional escape route when main entrance is blocked by flame or toxic smoke. However, the current fire evacuation system shows a lack of understanding from residents and thus is widely ignored for having insufficient safety functions, especially vis-à-vis fire emergencies. Studies have found that an alternative evacuation method, the escapable fire evacuation system, has been analyzed for safety evaluation compared with the conventional passive fire escape system and can bring efficient and safer solutions, providing high rise residents escape from fire accidents. Evaluation for safety evacuation has been performed by the Fire Dynamics Simulation and applying Pathfinder simulation. This resulted in providing appropriate escape routes within the safety escape time and allowed for people in high rise building fires to get to safety.

Trends in research and development of Evacuation modelling at Korea and Overseas (국내외 Evacuation modelling 연구 및 개발의 연구 동향)

  • Gu, Ji Won;Oh, Ryun Seok;Choi, Jun Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.233-234
    • /
    • 2022
  • In order to minimize casualties in case of a fire in a building, it is necessary to anticipate the time required for evacuation of occupants and the delay in evacuation in advance, and prepare countermeasures for possible occurrences. In fact, various factors that cannot be predicted exist and cannot be considered by excluding them, so the risk is predicted and evaluated through quantitative evacuation modeling. In order to understand this, we analyzed domestic and international evacuation modeling research trends. For about 40 years, starting with the characteristics of human movement, an evacuation modeling technique based on scientific methods has been developed through actual fire accident cases and various real-world experiments with humans. Then, in order to analyze the natural reaction of humans, which has a decisive influence in the recognition and decision-making phase, evacuation modelling studies have been conducted in depth using psychological and physical experimental methods.

  • PDF

A Study on the Evacuation Performance According to Variation in Remoteness between Exit Stairways in Tall Buildings

  • Han, Gisung;Kim, Tae-Young;Lee, Kyung-Hoon
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.53-61
    • /
    • 2020
  • The purpose of this study is to examine the influence of remoteness between exit stairways on evacuation performance. Firstly, we reviewed the design regulations of the U.S., the U.K., and South Korea, in relation to remoteness between Exit stairways. Secondly, evacuation simulation was implemented, in order to evaluate the adequacy of each standard. Eight tall buildings in South Korea were selected for the simulation. Evacuation performance was assessed for different remote distances between Exit stairways. Lastly, this research analyses the evacuation simulation data statistically in relation to the effect of remoteness on evacuation time. We found that as the distance between two exit stairways increases, the total evacuation time and average evacuation time for evacuees decreases. There was no statistical influence between the maximum travel distance of the evacuee and the remoteness between two exit stairways, but there was a significant effect on the average travel distance of the evacuees. In addition, the results from the optimal point showed that the L_ratio had the highest evacuation time at 0.44, while the D_ratio had the highest evacuation time at 0.38.

Evacuation Safety Evaluation for Apartment Complexes and Officetel under Floors (공동주택 및 오피스텔 지하층에 대한 피난 안전성 평가)

  • Hyeon-gwon Kang;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.67-72
    • /
    • 2023
  • Human and material damage can be reduced if the risk is evaluated by engineering analysis of fire combustion products, smoke concentration, and smoke movement speed in the event of a fire in apartment houses and officetels. In this study, a lot of research on related safety evaluation in the basement needs to be studied and reflected in design, so experimental research was conducted to analyze the flow of smoke through computer simulation and provide analysis data through evacuation safety evaluation. First of all, the five-story underground parking lot subject to simulation has a large floor area, which is advantageous for improving evacuation safety performance, but it uses temperature detectors to increase detection time and fire spread speed. Second, it was analyzed that the evacuation time at all evacuation ports did not exceed the evacuation time, and as the time from the start of evacuation to the evacuation time was 216.9% compared to the travel time, it was evaluated that the safety performance of the evacuation was secured. Third, the above simulation results are a comprehensive safety evaluation based on the non-operation of fire extinguishing facilities in the fire room to increase safety, which means that smoother evacuation safety performance can be secured by linking fire extinguishing facilities.

A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital (노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.1
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.

Analysis of the Effect of the Effective width of the Exit of the Evacuation Stairs on the Evacuation Time of the Occupants (피난계단 출입구 유효너비가 수용인원의 피난시간에 미치는 영향 분석)

  • Yang, Sung-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.73-79
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the relationship between the minimum effective width (90cm) of the exit of the evacuation stairway installed in accordance with the Building Act and the evacuation time of all occupants using the corresponding floor from an evacuation point of view. Method: The evacuation simulation (Pathfinder) was used to investigate how the change in doorway width affects the evacuation time of occupants. Result: It was found that as the effective width of the doorway became larger than the minimum standard of 90cm, the evacuation time to the evacuation stairs was shortened. This is also proof that the effective width of the evacuation stair entrance can be appropriately applied differently depending on the number of occupants on the floor. Conclusion: In the future, in order to secure evacuation safety of occupants, it is judged that the effective width standard for the exit of the evacuation stairway considering the total number of occupants by use is necessary. In addition, it is expected that the evacuation efficiency of occupants can be greatly increased if various effective width standards for entrances are made according to the number of occupants by use through research and experiments.

A study of on the occupant movement speed during emergency evacuations for the evacuation safety assessment of domestic buildings (국내 건축물의 피난안정성평가를 위한 비상대피 시 재실자 이동속도에 관한 연구)

  • Youn, Ho-Ju;Hwang, Eunkyung
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.332-338
    • /
    • 2013
  • Recently in Korea, in order to ensure evacuation safety within buildings, reviewing and evacuation assessment using computer simulations has been performed from the planning and design stages. Since the results from the assessment mainly depends on the initial values of input elements, it is important to establish element specific data. Nevertheless evacuation related experiments and research are still insufficient to apply overseas standards to domestic conditions. This study intended to conduct a experiment on evacuation movement speed by age as part of element-specific data construction for domestic occupant movement speed. After analyzing domestic and overseas studies on evacuation movement speed, we conducted the experiment of evacuation movement speed for 134 people. Then, by carrying out a comparative analysis of the results of the movement speed obtained from the experiment with overseas movement speeds, we followed the validation procedures of the experimental results under domestic evacuation conditions. The data derived from the experiment is expected to serve as a basis for the movement speed of domestic evacuation safety assessment.

A Study on the Evacuation Model Considering Occupancy Load in Child Care Center with Disabilities (장애아전문 어린이집 재실자 피난 부하를 고려한 피난 모델 연구)

  • Lee, Jeong-Soo;Oh, Young-Sook;Kwon, Yong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.553-561
    • /
    • 2021
  • The purposes of this study are to propose evacuation recommendations through evacuation model considering occupancy load model in child care center with disabilities. To achieve these purposes, the survey on the occupancy load and egress model and evacuation experiments have carried out, and evacuation occupancy load model for child care center with disabilities are suggested. The results of this study are as follows : (1) The evacuation plan for children with disabilities are necessary special considerations according the type and levels of disability, and various egress means and method for children in child care center with disabilities conditions. (2) The evacuation occupancy loads are different with non-impaired children and evacuation occupancy loads and evacuation corridors width are necessary considering impaired children's evacuation behaviors. (3) The temporal evacuation area(refuge area) is essential for children with disability who are impossible vertical evacuation such as impaired children using wheelchair and cerebral palsy.