• Title/Summary/Keyword: etched surface

Search Result 753, Processing Time 0.029 seconds

Investigation of Structural and Optical Properties of III-Nitride LED grown on Patterned Substrate by MOCVD (Patterned substrate을 이용하여 MOCVD법으로 성장된 고효율 질화물 반도체의 광특성 및 구조 분석)

  • Kim, Sun-Woon;Kim, Je-Won
    • Korean Journal of Materials Research
    • /
    • v.15 no.10
    • /
    • pp.626-631
    • /
    • 2005
  • GaN-related compound semiconductors were grown on the corrugated interface substrate using a metalorganic chemical vapor deposition system to increase the optical power of white LEDs. The patterning of substrate for enhancing the extraction efficiency was processed using an inductively coupled plasma reactive ion etching system and the surface morphology of the etched sapphire wafer and that of the non-etched surface were investigated using an atomic force microscope. The structural and optical properties of GaN grown on the corrugated interface substrate were characterized by a high-resolution x-ray diffraction, transmission electron microscopy, atomic force microscope and photoluminescence. The roughness of the etched sapphire wafer was higher than that of the non-etched one. The surface of III-nitride films grown on the hemispherically patterned wafer showed the nano-sized pin-holes that were not grown partially. In this case, the leakage current of the LED chip at the reverse bias was abruptly increased. The reason is that the hemispherically patterned region doesn't have (0001) plane that is favor for GaN growth. The lateral growth of the GaN layer grown on (0001) plane located in between the patterns was enhanced by raising the growth temperature ana lowering the reactor pressure resulting in the smooth surface over the patterned region. The crystal quality of GaN on the patterned substrate was also similar with that of GaN on the conventional substrate and no defect was detected in the interface. The optical power of the LED on the patterned substrate was $14\%$ higher than that on the conventional substrate due to the increased extraction efficiency.

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

AN EXPERIMENTAL STUDY ON THE ETCHING PATTERNS AND THE PENETRATION OF THE COMPOSITE RESIN TO HUMAN DECIDUOUS ENAMEL ETCHED WITH PHOSPHORIC ACID (인산(燐酸) 부식(腐蝕)에 의(依)한 유치(乳齒) 표면(表面) 변화(變化) 및 복합(複合)레진 침투(浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Shin, Wan-Young;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.10 no.1
    • /
    • pp.85-93
    • /
    • 1983
  • In one group that tested for the effects of grinding and etching on the deciduous teeth, S.E.M. examination on the ground or unground labial surface of deciduous maxillary central incisors were made after etching procedure with 40% phosphoric acid for 60 secs., 120 secs., 180 sees. each. In another group that tested for the degree of resin penetration to the ground and etched deciduous teeth, composite resin application was done to the ground deciduous maxillary central incisors that had been acid-etched for 30 secs., 60 secs., 90 sees., 120 sees., 180 secs. each. The tooth-resin specimens were cut at the middle 1/3 of the crown by 2mm thickness, and the adjacent tooth materials were demineralized by 10% hydrochloric acid, the author observed the tags of the resin replica with S.E.M.. Following results were obtained. 1. After 40% phosphoric acid etching, the unground deciduous enamel surface showed various types of etching pattern. 2. For the formation of regular micropores on deciduous enamel surface by acid etching with 40% phosphoric acid, the time over 120 secs. should be requested. 3. After 40% phosphoric acid etching, the ground deciduous enamel surface showed the same etching pattern that has been a preferential removal of prism peripheries despite different etching time. 4. On the ground group that etched over 60 secs. to 180 secs., the length of tags was $5{\mu}m$ to $8{\mu}m$, with a mean of $7{\mu}m$.

  • PDF

Surface Modification of PET Fabrics Treated with Sputter Etching (Sputter etching 처리에 의한 PET직물의 표면개질)

  • Koo, Bon Sik;Kim, Yong Hae;Cho, Yeun Chung;Park, Ki Ho;Won, Eun Hee;Koo, Kang;Son, Tae Won
    • Textile Coloration and Finishing
    • /
    • v.9 no.2
    • /
    • pp.50-56
    • /
    • 1997
  • Poly(ethylene terephthalate) (PET) has been etched by sputtering in the presence of argon gas and the resulting surface modifications investigated via weight loss, time of water permeation, half value period, scanning electron microscope(SEM) and color difference measurements. According to increasing sputter etching time, weight loss increased, the time of water permeation and half value period of the sputter etched PET fabrics decreased. Color depth of fabrics increased by increasing sputter etching time. We investigated the fabric surface modification by SEM. Many microcraters on the fabric surface formed by the sputter etching resulted in increase of surface area of the fabric and wettability.

  • PDF

Effect of hydrofluoric acid-based etchant at an elevated temperature on the bond strength and surface topography of Y-TZP ceramics

  • Yu, Mi-Kyung;Lim, Myung-Jin;Na, Noo-Ri;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.6.1-6.8
    • /
    • 2020
  • Objectives: This study investigated the effects of a hydrofluoric acid (HA; solution of hydrogen fluoride [HF] in water)-based smart etching (SE) solution at an elevated temperature on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics in terms of bond strength and morphological changes. Materials and Methods: Eighty sintered Y-TZP specimens were prepared for shear bond strength (SBS) testing. The bonding surface of the Y-TZP specimens was treated with 37% phosphoric acid etching at 20℃-25℃, 4% HA etching at 20℃-25℃, or HA-based SE at 70℃-80℃. In all groups, zirconia primers were applied to the bonding surface of Y-TZP. For each group, 2 types of resin cement (with or without methacryloyloxydecyl dihydrogen phosphate [MDP]) were used. SBS testing was performed. Topographic changes of the etched Y-TZP surface were analyzed using scanning electron microscopy and atomic force microscopy. The results were analyzed and compared using 2-way analysis of variance. Results: Regardless of the type of resin cement, the highest bond strength was measured in the SE group, with significant differences compared to the other groups (p < 0.05). In all groups, MDP-containing resin cement yielded significantly higher bond strength values than MDP-free resin cement (p < 0.05). It was also shown that the Y-TZP surface was etched by the SE solution, causing a large change in the surface topography. Conclusions: Bond strength significantly improved when a heated HA-based SE solution was applied to the Y-TZP surface, and the etched Y-TZP surface was more irregular and had higher surface roughness.

AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO AIR-ABRADED ENAMEL AND DENTIN (표면처리방법에 따른 복합레진의 결합강도에 관한 실험적 연구)

  • Shin, Jae-Ho;Jang, Ki-Taeg;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.112-124
    • /
    • 1997
  • According to extensive use of composite resin which have superior esthetic property, every effort on improving bonding strength between a tooth and composite resin has been continued. Acid etching technique is a method that micro-etches the tooth surface which provides bonding with composite resin possible. Recently, there were several reports that mechanical treatment obtained from air-abrasion can provide similar bonding strength with acid etching technique. So, this experimental study was designed to compare the shear bonding strength between using air-abrasion technique and using acid etching technique. Initially, bovine teeth were divided into enamel and dentin experimental groups. Respectively each group was categorized into three subgroups. One subgroup was acid etched with 35% phosphoric acid, then bonded with composite resin. The other subgroup was air-abraded with $50{\mu}m$ $Al_2O_3$ particles sprayed with 160psi air pressure using air abrasion unit(KCP-1000, A.D.T., U.SA), and composite resin was bonded. In another subgroup, composite resin was bonded after acid etching following air-abrasion. So, enamel experimental groups were made of E1 (acid etched only), E2(air-abraded only), E3(acid etched following air-abraded), and dentin experimental groups were made of D1(acid etched only), D2(air-abraded only), D3(acid etched following air-abraded). Each subgroup had 10 specimens. Dentin bonding system(Scotchbond Multi-purpose, 3M Co., U.S.A.) and composite resin(Z-100, 3M Co., U.S.A.) were applied on treated surface using 5mm diameter gelatin capsule as manufacturer's direction. After 1200 times thermocycling between $5^{\circ}C$ and $55^{\circ}C$, shear bond strength was measured in 5mm/min crosshead speed with Instron(Instron Co., U.S.A.), and also treated enamel and dentin were observed with SEM(JEOL Co., Japan). The following results were obtained: 1. In the enamel experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 2. In the dentin experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 3. In the SEM study, air-abraded enamel and dentin had irregular and rough surfaces.

  • PDF

Influence of surface treatment on the insertion pattern of self-drilling orthodontic mini-implants (표면처리가 교정용 미니 임플랜트의 식립수직력과 토크에 미치는 영향)

  • Kim, Sang-Cheol;Kim, Ho-Young;Lee, Sang-Jae;Kim, Cheol-Moon
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.268-279
    • /
    • 2011
  • Objective: The purpose of this study was to compare self-drilling orthodontic mini-implants of different surfaces, namely, machined (untreated), etched (acid-etched), RBM (treated with resorbable blasting media) and hybrid (RBM + machined), with respect to the following criteria: physical appearance of the surface, measurement of surface roughness, and insertion pattern. Methods: Self-drilling orthodontic mini-implants (Osstem implant, Seoul, Korea) with the abovementioned surfaces were obtained. Surface roughness was measured by using a scanning electron microscope and surface-roughness-testing machine, and torque patterns and vertical loadings were measured during continuous insertion of mini-implants into artificial bone (polyurethane foam) by using a torque tester of the driving-motor type (speed, 12 rpm). Results: The mini-implants with the RBM, hybrid, and acid-etched surfaces had slightly increased maximum insertion torque at the final stage ($p$ < 0.05). Implants with the RBM surface had the highest vertical load for insertion ($p$ < 0.05). Testing for surface roughness revealed that the implants with the RBM and hybrid surfaces had higher Ra values than the others ($p$ < 0.05). Scanning electron microscopy showed that the implants with the RBM surface had the roughest surface. Conclusions: Surface-treated, self-drilling orthodontic mini-implants may be clinically acceptable, if controlled appropriately.

Effect of Annealing under Antimony Ambient on Structural Recovery of Plasma-damaged InSb(100) Surface

  • Seok, Cheol-Gyun;Choe, Min-Gyeong;Jeong, Jin-Uk;Park, Se-Hun;Park, Yong-Jo;Yang, In-Sang;Yun, Ui-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.203-203
    • /
    • 2014
  • Due to the electrical properties such as narrow bandgap and high carrier mobility, indium antimonide (InSb) has attracted a lot of attention recently. For the fabrication of electronic or photonic devices, an etching process is required. However, during etching process, enegetic ions can induce structural damages on the bombarded surface. Especially, InSb has a very weak binding energy between In atom and Sb stom, it can be easily damaged by impingement of ions. In the previous work, to evaluate the surface properties after Ar ion beam etching, the plasma-induced structural damage on the etched InSb(100) surface had been examined by resonant Raman spectroscopy. As a result, we demonstrated the relation between the enhanced transverse optical(TO) peak in the Raman spectrum and the ion-induced structral damage near the InSb surface. In this work, the annealing effect on the etched InSb(100) surface has investigated. Annealing process was performed at $450^{\circ}C$ for 10 minute under antimony ambient. As-etched InSb(100) surface had shown a strongly enhanced TO scattering intensity in the Raman spectrum. However, the annealing process with antimony flowing caused the intensity to recover due to the structural reordering and the reduction of antimony vacancies. It proves that the origin of enhanced TO scattering is Sb vacancies. Furthermore, it shows that etching-induced damage can be cured effectively by the following annealing process under Sb ambient.

  • PDF

Surface Reaction of Ru Thin Films Etched in CF 4/O2 Gas Chemistry (CF4/O2 Gas Chemistry에 의해 식각된 Ru 박막의 표면 반응)

  • 임규태;김동표;김경태;김창일;최장현;송준태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1016-1020
    • /
    • 2002
  • Ru thin films were etched using CF/$_4$O$_2$ plasma in an ICP (inductively coupled plasma etching) system. The maximum etch rate of Ru thin films was 168 nm/min at a CF$_4$/O$_2$ gas mixing ratio of 10 %. The selectivity of SiO$_2$ over Ru was 1.3. From the OES (optical emission spectroscopy) analysis, the optical emission intensity of the O radical had a maximum value at 10% CF$_4$ gas concentration and drcrease with further addition of CF4 gas, but etch slope was enhanced. From XPS (x-ray photoelectron spectroscopy) analysis, the surface of the etched Ru thin film in CF$_4$/O$_2$ chemistry shows Ru-F bonds by the chemical reaction of Ru and F. RuF$_{x}$ compounds were suggested as a surface passivation layer that reduces the chemical reactions between Ru and O radicals. From a FE-SEM (field emission scanning electron microscope) micrograph, we had an almost perpendicular taper angle of 89$^{\circ}$.>.

A STUDY ON THE MICROSCOPIC CHANGE OF THE ENAMEL SURFACE AFTER ACID ETCHING (법랑질(琺瑯質)의 산탈회(酸脱灰)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Min, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.37-50
    • /
    • 1980
  • Scanning Electron Microscopic (SEM) examination on the labial surface of 91 permanent upper incisors were made after etching procedure with phosphoric acid, sulfuric acid, nitric acid, hydro chloric acid, oxalic acid, formic acid, citric acid and zinc phosphate liquid for 2 minutes. Following results were obtained. 1. In the surfaces etched by 10%. 50% phosphoric acid, 50% sulfuric acid, 10%. 30% nitric acid, 10%. 50% oxalic acid, 10%. 30%. 50% formic acid, 30%. 50% citric acid and zinc phosphate liquid, there appeared to be a preferential removal of prism cores, but in the surfaces etched by 10% phosphoric acid, 50% nitric acid, 10%. 30% hydrochloric acid and 30% oxalic acid, the prism peripheries were removed preferentially. 2. According to Silverstone classification on enamel etching pattern the surface treated by zinc phosphate liquid, 30. 50% citric acid, 10%. 30%. 50% formic acid, 10%. 50% oxalic acid, 10%. 30% nitric acid, 50% sulfuric acid and 10%. 50%. phosphoric acid showed Type 1, and etched by 30% oxalic acid, 10%. 30% hydrochloric acid, 50% nitric acid and 10% phosphoric acid showed Type II. Etching of prism cores was by far the most common occurence. The changes produced could be related to intrinsic differences in histology and / or solubility of enamel.

  • PDF