The change of rotational freedom following different insertion torques in three implant systems with implant driver

  • Kwon, Joo-Hyun;Han, Chong-Hyun;Kim, Sun-Jai;Chang, Jae-Seung
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.37-40
    • /
    • 2009
  • STATEMENT OF PROBLEM. Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE. This study evaluated the change of rotational freedom between an implant and its abutment after application of different insertion torques. MATERIAL AND METHODS. Three kinds of internal connection implants were utilized for the current study($4.5{\times}12\;mm$ Xive, $4.3{\times}11.5\;mm$ Inplant Magicgrip, $4.3{\times}12\;mm$ Implantium MF). An EstheticBase, a 2-piece top, a Dual abutment was used for its corresponding implant system. The rotational freedom between an implant and its abutment were measured before and after applying 45, 100 Ncm insertion torque. Repeated measures ANOVA was used for statistical analysis. RESULTS. Under 45 Ncm insertion torque, the rotational freedom between an implant and its abutment was significantly increased in Xive(P = .003). However, no significant change was noted in Inplant Magicgrip and Implantium MF. Under 100 Ncm torque, both in Xive(P = .0005) and Implatium MF(P = .03) resulted in significantly increased rotational freedom between the implant and its abutment. DISCUSSION. The design of the implant/implant driver interface effectively prevented the deformation of implant/abutment interface. Little change was noted in the rotational freedom between an implant and its abutment, even though the insertion torque was far beyond clinical application. CONCLUSIONS. The implant/abutment joint of internally connecting implants were quite stable under insertion torque in clinical situation.

우리나라 남성 골프웨어에 나타난 패션 경향 분석 (An Analysis of the Fashion Trends Expressed on the Korean Men´s Golfwears)

  • 이효진
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.748-762
    • /
    • 2002
  • The purpose of this study was to analyze the fashion trends of Korean men's golfwears and furnished the researchers of same major with reliable data base. Lately, Korean men were concerned about their appearance rather than social position. Moreover, they tried to express the needs of youthfulness with free lift through clothings. These trend had been showed itself not only development of golfwears, but also change of esthetic tastes of men's golfwears. First of all, the development of men's golfwears was affected by the major three factors out of many various factors. That is, popularization of golf by the international activities of Korean progolfers, appearance of young consumers after IMF and the casualization of the men's formal dress, the making an everyday dress of men's sportswears. The results of analyzing of fashion trends of the men's golfwears is as follow: 1. The characteristics with naturalness, comfort of men's golfwears was manifested casualization trends by the factors of downward tendency of golfer's age, 5-days working, men's biz casual preference, individual ism after IMF. 2. Men's character golfwears was showed by the ageless as a youthfulness expression, the Sportism as an international trend, 2002 world cup, etc. 3. All of golfwears have to be functional characteristics because the golf is an active sports spending long time in golf course. Unconstruction style was an important fashion trends of men's golfwears by using functional materials to meet the needs of consumers. 4. The men's clothing was deviated from a fixed idea called masculine after IMF. Moreover, this trend was increased by the appearance of lovely man, genderlessness and had an effect on men's golfwears. Consequently. men's golfwears was showed feminization characteristics as a feminine, sensitive style. In the future, Korean men will try to express their character and thought freely through golfwears, men's golfwears will be continued ‘beyond the golf course’ image reflecting in the future fashion trends.

  • PDF

Influence of modeling agents on the surface properties of an esthetic nano-hybrid composite

  • Kutuk, Zeynep Bilge;Erden, Ecem;Aksahin, Damla Lara;Durak, Zeynep Elif;Dulda, Alp Can
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.13.1-13.10
    • /
    • 2020
  • Objective: The aim of this study was to evaluate the influence of different modeling agents on the surface microhardness (Vickers hardness number; VHN), roughness (Ra), and color change (ΔE) of a nano-hybrid composite with or without exposure to discoloration by coffee. Materials and Methods: Sixty-four cylinder-shaped nano-hybrid composite specimens were prepared using a Teflon mold. The specimens' surfaces were prepared according to the following groups: group 1, no modeling agent; group 2, Modeling Liquid; group 3, a universal adhesive (G-Premio Bond); and group 4, the first step of a 2-step self-adhesive system (OptiBond XTR). Specimens were randomly allocated into 2 groups (n = 8) according to the storage medium (distilled water or coffee). VHN, Ra, and ΔE were measured at 24 hours, 1 week, and 6 weeks. The Kruskal-Wallis test followed by the Bonferroni correction for pairwise comparisons was used for statistical analysis (α = 0.05). Results: Storage time did not influence the VHN of the nano-hybrid composite in any group (p > 0.05). OptiBond XTR Primer application affected the VHN negatively in all investigated storage medium and time conditions (p < 0.05). Modeling Liquid application yielded improved Ra values for the specimens stored in coffee at each time point (p < 0.05). Modeling Liquid application was associated with the lowest ΔE values in all investigated storage medium and time conditions (p < 0.05). Conclusion: Different types of modeling agents could affect the surface properties and discoloration of nano-hybrid composites.

치과의원의 실내 공간에 나타난 아이덴티티 요소에 관한 연구 - 서울과 부산지역의 치과의원 중심으로 - (A Study on Identity Elements Expressed in the Inner Spaces of Dental Clinics - Focused on dental clinics in areas of Seoul and Busan -)

  • 최시영;이창노
    • 한국실내디자인학회논문집
    • /
    • 제19권1호
    • /
    • pp.217-225
    • /
    • 2010
  • As life quality have grown today, People have been greatly interested in health. Moreover, new knowledge and concepts are being applied in the medical facility field and that makes the field expand constantly. Hereby, this research is a study on design elements of dental clinics and the research goals are to understand interior design of current dental clinics by investigation and analysis on furniture, closing materials, colors and so on, and to investigate esthetic and functional environments for dental clinics through analyzing upcoming trends of inner spaces of dental clinics. The investigation was conducted by visits to four clinics per each research area, where are in Busan area and opened after year 2000 and are located in Seoul and Busan. Though the spaces of dental clinics vary according to the characteristics of each clinic, it generally has a consultation room, a waiting room and an X-ray room. The closing materials that make patients feel at ease are used in the waiting room, and ones that make patients feel tidy and fresh are used in consultation spaces, spare spaces, and management spaces. In Seoul area, antique and harmonic colors are used, and modernistic colors are used in Busan area. Reception desks, chair units, sofas and sink storage shelfs are the common furniture in the clinic. We have learned what are mentioned above by research and investigation on the component characteristics of dental clinic spaces. Based on these, more systematical and in-depth research should be continued.

Usefulness of the orbicularis oculi myocutaneous flap in periorbital reconstruction

  • Kim, Geon Woo;Bae, Yong Chan;Kim, Joo Hyoung;Nam, Su Bong;Kim, Hoon Soo
    • 대한두개안면성형외과학회지
    • /
    • 제19권4호
    • /
    • pp.254-259
    • /
    • 2018
  • Background: The esthetic and functional outcomes of periorbital defect reconstruction are very important because of the complex anatomy and specialized functions of this region. The orbicularis oculi myocutaneous (OOMC) flap is useful for the reconstruction of periorbital defects. But, according to the location and depth of the defects, the reconstruction using OMC flaps with various techniques is rare. The authors have used various kinds of OOMC flaps in various situations and we present an analysis of our experiences. Methods: From November 2001 to July 2017, we used 36 OOMC flaps to reconstruct 30 periorbital defects in 25 patients. We analyzed the cause of the defect, its location, the type of concomitant surgery, the method of flap movement, and complications. Results: Of the 30 defects, basal cell carcinoma was the most common cause, accounting for 20 cases. When the used OOMC flap was classified according to the location of the defects, the switch flap was used in nine cases among 15 defects of lower eyelid, and the V-Y advancement flap was mainly used for other parts. As surgical methods according to the depth of defect were classified, all cases involving the tarsal plate were reconstructed with a composite graft. In case of skin and muscles, they were reconstructed only with OOMC flap or with full-thickness skin graft. Conclusion: The OOMC flap provides good skin quality that is very similar to that of the defect tissue. Depending on the location and depth of the defect, the OOMC flap may be used properly in a variety of ways to achieve good results.

Cone-beam computed tomography-guided three-dimensional evaluation of treatment effectiveness of the Frog appliance

  • Li, Mujia;Su, Xiaoxia;Li, Yang;Li, Xianglin;Si, Xinqin
    • 대한치과교정학회지
    • /
    • 제49권3호
    • /
    • pp.161-169
    • /
    • 2019
  • Objective: To evaluate the effectiveness of the Frog appliance in three dimensions by using cone-beam computed tomography (CBCT) images. Methods: Forty patients (21 boys and 19 girls), averaged 11.7 years old, with an Angle Class II division 1 malocclusion were included in our study. They had either late mixed dentition or early permanent dentition, and the maxillary second molars had not yet erupted. All patients underwent CBCT before and after the treatment for measuring changes in the maxillary first molars, second premolars, central incisors, and profile. Paired-samples t-test was used to compare the mean difference in each variable before treatment and after the first phase of treatment. Results: The maxillary first molars were effectively distalized by 4.25 mm (p < 0.001) and 3.53 mm (p < 0.05) in the dental crown and root apex, respectively. The tipping increased by $2.25^{\circ}$, but the difference was not significant. Moreover the teeth moved buccally by 0.84 mm (p < 0.05) and 2.87 mm (p < 0.01) in the mesiobuccal and distobuccal cusps, respectively, whereas no significant changes occurred in the root apex. Regarding the anchorage parts, the angle of the maxillary central incisor's long axis to the sella-nasion plane increased by $2.76^{\circ}$ (p < 0.05) and the distance from the upper lip to the esthetic plane decreased by 0.52 mm (p = 0.01). Conclusions: The Frog appliance effectively distalized the maxillary molars with an acceptable degree of tipping, distobuccal rotation, and buccal crown torque, with only slight anchorage loss. Furthermore, CBCT image demonstrated that it is a simple and reliable method for three-dimensional analysis.

In vivo wear determination of novel CAD/CAM ceramic crowns by using 3D alignment

  • Aladag, Akin;Oguz, Didem;Comlekoglu, Muharrem Erhan;Akan, Ender
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.120-127
    • /
    • 2019
  • PURPOSE. To determine wear amount of single molar crowns, made from four different restoratives, and opposing natural teeth through computerized fabrication techniques using 3D image alignment. MATERIALS AND METHODS. A total of 24 single crowns (N = 24 patients, age range: 18 - 50) were made from lithium disilicate (IPS E-max CAD), lithium silicate and zirconia based (Vita Suprinity CAD), resin matrix ceramic material (Cerasmart, GC), and dual matrix (Vita Enamic CAD) blocks. After digital impressions (Cerec 3D Bluecam, DentsplySirona), the crowns were designed and manufactured (Cerec 3, DentsplySirona). A dualcuring resin cement was used for cementation (Variolink Esthetic DC, Ivoclar). Then, measurement and recording of crowns and the opposing enamel surfaces with the intraoral scanner were made as well as at the third and sixth month follow-ups. All measurements were superimposed with a software (David-Laserscanner, V3.10.4). Volume loss due to wear was calculated from baseline to follow-up periods with Siemens Unigraphics NX 10 software. Statistical analysis was accomplished by Repeated Measures for ANOVA (SPSS 21) at = .05 significance level. RESULTS. After 6 months, insignificant differences of the glass matrix and resin matrix materials for restoration/enamel wear were observed (P>.05). While there were no significant differences between the glass matrix groups (P>.05), significant differences between the resin matrix group materials (P<.05) were obtained. Although Cerasmart and Enamic were both resin matrix based, they exhibited different wear characteristics. CONCLUSION. Glass matrix materials showed less wear both on their own and opposing enamel surfaces than resin matrix ceramic materials.

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

Bentham의 쾌락계산법에 기초한 건축미 가치추정 방법론적 소고 (A Methodological Thinking on Valuation Analysis of the Architectural Aesthetic based on the Hedonic Calculus by Bentham)

  • 이동주;고은형
    • 대한건축학회논문집:계획계
    • /
    • 제34권4호
    • /
    • pp.11-18
    • /
    • 2018
  • The beauty is like the bubble of beer, and behavior scholars have been regarded as worthless to study. As a result, the aesthetic in construction projects has resulted in underestimation or neglect. The fundamental cause of this result is that it is not easy to estimate the value of the aesthetic. The hedonic calculus by Bentham has a possibility to valuating the intangible or invisible goods. In this context, this study proposes a method to valuate architectural aesthetic based on the hedonic calculus by Bentham. As a precondition for suggesting the valuation method, this study defined the architectural aesthetic as the value of attraction that affects the value of the built environment. As the concept of beauty that conforms to the architectural aesthetic, it has established the concept of beauty as 'the phenomenon of combining the foreground and background of Hartmann'. In addition, the scope of the value measurement is defined as 'built environment' so as to include not only the building but also the surrounding environment. We have reinterpreted the seven dimension of the hedonic calculus proposed by Bentham and systematized the method of valuation of the architectural esthetic based on the seven dimension. The result of this study is meaningful in that it presents a new perspective and approach to architectural aesthetic. And it will be used as grounds for valuation and analytical approach to architectural aesthetic and will be used as a basis for expanding the field of study from aesthetic to value.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제51권2호
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.