• Title/Summary/Keyword: escalator

Search Result 76, Processing Time 0.018 seconds

Analysis of User Satisfaction by Types of Subway Platforms and Transit Stations (지하철 승강장 및 환승정거장 유형에 따른 이용자 만족도 분석)

  • Kim, Hwang Bae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.437-445
    • /
    • 2015
  • The layout of facilities, in relation to information and navigational displays, has great influence on subway satisfaction, and tend to vary depending on the types of subway platform and transit station. However, until now, few studies have covered such aspects as of yet. Starting from this viewpoint, the purpose of this study was to use an IPA analysis technique to analyze that satisfaction on the importance of facilities to aid in accessibility, such as elevators and escalators, transit amenities and information and navigational displays depending on the types of platform and transit station. To do so, we've classified 15 metropolitan stations according to types of platform and transit station and analyzed differences in user importance and satisfaction as well as improvements for platforms and transit stations of similar type. By the analysis results of this study, we've concluded that the proper selection and positioning of elevator and escalator facilities and information and navigational displays was important when designing the subway station according to platform type (separate platform) and or according to the transit station type (cross, L, T types) where pedestrian flow heavily intersected. We considered that such analysis results would be helpful in the design of new stations and the enhancement of existing stations pursuant to a new direction that minimizes user inconvenience, and that improvement items should be developed first according to the platform and transit station types, which would be helpful in enhancing the efficiency of the subway improvement cost.

Basic Experimental Study on the Characteristics of Way Selection for the Development of Evacuation Simulation Model on board a Ship (선내 피난모델 개발을 위한 피난경로 선택특성에 관한 기초실험 연구)

  • Hwang, Kwang-Il;Sim, Young-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.39 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • As the numbers of users of domestic passenger ships increased up to 14.5 millions at 2012, the numbers of ships accidents also increased as 2 times than ever. It will be very important to develop technologies related with safety design for onboard passengers and disclose the potential problems. This study performed consciousness survey on ordinary peoples' way finding who have not got any regular anti-disaster training, to develop evacuation models for evacuation feasibility studies. Followings are the results answered by 83 participants for 33 way finding questions. Respondents selected right ways more than 6~18% for 2 ways like T type, U type, Y type passages. But when there are some walkers and/or runners, respondents preferred to select the way where walkers or runners are. And more over the ratio of the ways that runners are on is comparatively higher than walkers. On 'ㅏ'type, 'ㅓ'type and 3 way type passages, even though the walkers and/or runners are affected to answerers, straight way were most preferred. And it is clear that peoples like bright passages. On the other hands, peoples responded as they like right, downward and near stairs more than left, upward and far stairs, respectively. and very few selected escalator and elevator for as evacuation stairs.

Derivation of Safety Management Implications through Analysis of Major Elevator Failures (승강기 중대고장 분석을 통한 안전관리 시사점 도출)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.23-29
    • /
    • 2020
  • As the duty to report and investigate major elevator failures has expanded due to the total amendment of the Elevator Safety Management Act in 2018, more important information on major elevator failures that have been partially identified has been collected. As of 2019, the number of elevators in Korea exceeded 700,000, making it the eighth-class elevator powerhouse in the world, but there is a trend of increasing casualties due to accidents and breakdowns. An Seung-gang-gi is a term that encompasses an elevator that moves vertically and an escalator that moves horizontally. It is an important means of transportation for most citizens that are encountered almost every day in daily life, and it is also necessary as a means of transportation that enables the construction of skyscrapers. And it seems that its importance will never diminish in the future. Major elevator failures are the main cause of dispatch when accumulating the number of 119 dispatches, and the frequency of occurrence is high. It's a shame. According to Heinrich's Law, 300 minor signs and danger phenomena precede, 29 minor accidents and 1 major accident. Accidents caused by elevators are increasing every year due to the increase in the number of installations, and the damage is threatening the valuable lives and property of users and workers in related fields due to fatal risks such as death and serious injury. Elevator safety management can achieve its purpose only when it is managed with the usual interests, awareness of safety, and full efforts of the users, workers, and the government concerned. This study was analyzed based on 2019 data notified to the Korea Elevator Safety Agency on major breakdowns improved after the revision of the Elevator Safety Management Act in 2018, and a total of 8,256 data were analyzed using the SPSS 21 version, a statistical analysis tool, to analyze the correlation with technical statistics. Proceeded. Through the analysis, it was possible to obtain preventive safety management data to prevent serious elevator safety accidents from occurring, and to derive meaningful implications that related safety management and maintenance can be effectively operated to prevent serious failures. In addition, through this analysis, we expect the development of related industries and legal and institutional improvement.

Effect of Artificial Zeolite on Fermentation and Emission of Ammonia and Methane during Animal Waste Composting (인공제올라이트 처리가 가축분 퇴비의 발효 및 암모니아, 메탄가스 발생에 비치는 영향)

  • Lee, Deog-Bae;Kim, Jong-Gu;Lee, Kyung-Bo;Lee, Sang-Bok;Kim, Jae-Duk
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.5
    • /
    • pp.361-368
    • /
    • 2000
  • This study was carried out to investigate the influence of artificial zeolite on the change of temperature, gas emission, water content and chemical properties during the composting process with the mixture of animal feces, broken bark and extruded rice hull. Artificial zeolite was added 0, 0.5, 1, 3 and 5% volume of the raw composting material, and proceeded 1.2m every day with mobile stacking escalator. Temperature was increased, and water content was decreased in the composting pile by addition of artificial zeolite. This caused to accelerate decomposition of organic matter during composting. $NH_3$ was emitted the highest at 6th day after stacking, then decreased gradually. And addition of artificial zeolite caused to decrease greatly in $NH_3$ emission from composting pile. As result of this, content of nitrogen in the compost was increased by addition of artificial zeolite. Emission of $CH_4$ was the highest at early stacking stage, and that was decreased drastically at 8th day. Emission of $CH_4$ was also decreased greatly by addition of artificial zeolite at 5th days after stacking. It may be resulted from adsorption of $CH_4$ into the molecular sieve structure of artificial zeolite and low water content by high temperature fermentation.

  • PDF

Safety Management Improvement Plan for Elevator Worker Safety Accident Prevention (승강기작업자 안전사고예방을 위한 안전관리 개선 방안)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.23-29
    • /
    • 2020
  • Korea's elevator industry is one of the world's eighth-largest industrial sectors and the third largest in the world by new installations. This year, the number of elevators has exceeded 700,000, and the number of new installations is 30,000-40,000 every year. However, the news of elevator-related accidents is reported continuously through the media and the accident rate is not decreasing. In particular, among the recent accidents related to elevators, accidents related to elevator workers are increasing, causing social problems. This year, the National Assembly's Environmental Labor Relations Commission's National Auditors lost five lives a year and 12 elevator workers were killed in fall and stenosis accidents during the installation, maintenance and replacement of the elevators for about two years since 2018. It took place to adopt the representatives of four domestic elevator companies as witnesses. An elevator worker is a collective term for workers involved in the design, manufacturing, installation, replacement, maintenance, inspection, management, and supervision related to the elevator industry, and the related accidents are called elevator worker accidents. Analysis of elevator-related accidents in the past has shown that the fault of the user accounted for 70% of the total, and the fault of the worker accounted for about 2.5%, and the accident occurred to the user or the user due to carelessness of the worker during the lift-related work. Currently, elevator-related accidents are reported by the Korea Elevator Safety Agency under Article 48 of the Elevator Safety Management Act under the Ministry of Interior and Safety. If deemed necessary for the prevention and prevention of recurrence of an elevator accident, the cause and condition of the elevator accident may be investigated. However, the current draft law is limited only to elevators after installation inspection, and is separated from the Ministry of Employment and Labor's data on accidents occurring in the manufacturing and installation stages related to the elevator industry. This study analyzes the recent safety accidents of elevator workers and prepares safety measures to prevent them through the risk analysis, and also draws out the problems and improvements of the current elevator worker accident investigation to find the elevator worker accident rate that is on the increase trend.

Investigation on the Amount of Water Evaporation from Composting Facilities Operated in Swine Farms (양돈농가에서 퇴비화시설별 수분변화량 분석에 관한 연구)

  • Kwag, J.H.;Choi, D.Y.;Park, C.H.;Jeong, J.H.;Kim, J.H.;Yoo, Y.H.;Jeon, B.S.;Ra, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.193-200
    • /
    • 2008
  • The results of the research on the amount of water evaporation from composting facilities operated in swine farms are below. The number of swine per a farm was 1433 head/farm for a Simple Composting Facility (SCF) and 3500 head/farm for a Escalator composting facility(ECF) system. The capacities of the SCF and the ECF were $0.33m^3/head$ and $0.25m^3/head$, respectively. The ECF had 24.2% less capacity than the SCF. The average water contents in the swine manure for the CP and the ECF of the surveyed farms were 86.8% and 85.7%, respectively, which revealed the ECF had 1.3% less average water content than the SCF. Daily water inputs into the SCF and the ECF were $4.1kg/m^3/day$ and $6.5kg/m^3/day$, respectively. The ECF had approximately 36.9% higher water input than the SCF. Fermentation temperatures during the composting period for the SCF and the ECF were up to $45^{\circ}C$ and $70^{\circ}C$, respectively. The decreases in water contents per each square meter for the SCF and the ECF were 3.7 kg and 5.2 kg, respectively. The ECF lost approximately 28.8% more water content than the ECF, which would be caused by the difference of fermentation temperature between two systems. Fertilizer components after composting were examined. Nitrogen contents of the SCF and the ECF were similar (0.84% and 0.86%, respectively) and ${P_2}{O_5}$ contents were 0.78% and 0.74%, respectively, showing the SCF had slightly higher content than the ECF. However, OM and OM/N did not show the difference between two systems. Hence, efforts to increase composting efficiency with considerations of the water content of swine manure, fermentation temperature, and water evaporation potential should be done when the SCF and the ECF were used in swine farms.

  • PDF