• Title/Summary/Keyword: error range

Search Result 2,816, Processing Time 0.029 seconds

The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation (시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발)

  • Eom, Jae-Yong;Lee, Chung-Kook;Jang, Weol-Sang;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

Estimation of Volume-Area-Depth Relationship for Shallow Wetland (습지의 체적-면적-깊이에 대한 관계식 추정)

  • Kim, Jun-Gwon;Kim, Hyeong-Su;Jeong, Sang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.231-240
    • /
    • 2002
  • The wetland has very important functions in hydrologic and ecological aspects and the research of wetland functions requires the basic hydrological properties such as water quantity. However, we do not have a research work on the hydrological properties for a wetland study in Korea. Therefore, this study is to estimate the relations between the volume(V), the area(A), and the depth(h) of water in the wetland which might be the basis for the wetland research in Korea. To estimate the relations, we derive the basic equations, obtain the surveyed data and do modelling, and estimate the relations of A-h and V-h using the Surfer program. The estimated and observed volumes for 5-wetland are compared and the errors are in the range of 2 % to 11 % for 4-wetland and 34 % for the rest. The wetlands in small errors showed the similar ones with the profile of the wetted perimeter which is assumed for the derivation of the equation but the wetland of large error has much different profile with the assumed one. We re-estimate the volumes for 3-wetland(W3, W4, W5) which showed the large errors due to the bended profiles of the wetland slopes. say, after the slopes was divided into two parts of upper and lower ones, the volumes were estimated. From our re-estimation, we obtained very good results ranged from 1 % to 8 % in their errors. We conjecture that the procedure suggested in this study might be useful as a reference for the future research on the relations of V-A-h in Korea.

Evaluation of multi-objective PSO algorithm for SWAT auto-calibration (다목적 PSO 알고리즘을 활용한 SWAT의 자동보정 적용성 평가)

  • Jang, Won Jin;Lee, Yong Gwan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.9
    • /
    • pp.803-812
    • /
    • 2018
  • The purpose of this study is to develop Particle Swarm Optimization (PSO) automatic calibration algorithm with multi-objective functions by Python, and to evaluate the applicability by applying the algorithm to the Soil and Water Assessment Tool (SWAT) watershed modeling. The study area is the upstream watershed of Gongdo observation station of Anseongcheon watershed ($364.8km^2$) and the daily observed streamflow data from 2000 to 2015 were used. The PSO automatic algorithm calibrated SWAT streamflow by coefficient of determination ($R^2$), root mean square error (RMSE), Nash-Sutcliffe efficiency ($NSE_Q$), and especially including $NSE_{INQ}$ (Inverse Q) for lateral, base flow calibration. The results between automatic and manual calibration showed $R^2$ of 0.64 and 0.55, RMSE of 0.59 and 0.58, $NSE_Q$ of 0.78 and 0.75, and $NSE_{INQ}$ of 0.45 and 0.09, respectively. The PSO automatic calibration algorithm showed an improvement especially the streamflow recession phase and remedied the limitation of manual calibration by including new parameter (RCHRG_DP) and considering parameters range.

Evaluation of Field Application of Portable Near Infrared Reflectance Spectrometer (NIRS) for Quality Evaluation of Italian Ryegrass Silages (신속한 이탈리안라이그라스 사일리지의 품질평가를 위한 소형 근적외선분광기(NIRS)의 현장 적용성 평가)

  • Park, Hyung-Soo;Lee, Sang-Hoon;Kim, Jong-Gun;Choi, Ki-Choon;Seo, Sung;Kim, Won-Ho;Lee, Hyo-Won;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.415-422
    • /
    • 2011
  • This study evaluated the feasibility of using a portable near infrared reflectance spectrometer working in the 900~1,600 nm range for the measurement of quality-related parameters (moisture, pH, Acid detergent fiber (ADF), Neutral detergent fiber (NDF), Crude protein (CP), lactic acid) in intact silage. The calibration result for the Phazir (handheld, Polychromix) was compared with the result for the Spectrastar (Lab. based, Unity). A total of 67 Italian ryegrass silages were used to build calibration models using different spectral signal pre-treatments and the partial least squares regression (PLS) method. The good calibration statistics in two instruments was obtained for moisture content of Italian ryegrass silages with over $R^2$ = 0.95. The Phazir spectrometer was less accurate in measuring of ADF, NDF and CP contents. The Spectrastar instrument yielded greater precision for pH and lactic acid content; statistic values were over $R^2$ = 0.82 and the standard error of calibration (SEC) = 0.21% and 0.24%. Thus, the NIR measurement of forage quality in the field by portable NIR analyzers was shown not to be feasible, but additional investigations are required to discern the key instrumental and operational parameters that may influence the portable NIR measurement.

Estimation of soil moisture based on sentinel-1 SAR data: focusing on cropland and grassland area (Sentienl-1 SAR 토양수분 산정 연구: 농지와 초지지역을 중심으로)

  • Cho, Seongkeun;Jeong, Jaehwan;Lee, Seulchan;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.973-983
    • /
    • 2020
  • Recently, SAR (Synthetic Aperture Radar) is being highlighted as a solution to the coarse spatial resolution of remote sensing data in water resources research field. Spatial resolution up to 10 m of SAR backscattering coefficient has facilitated more elaborate analyses of the spatial distribution of soil moisture, compared to existing satellite-based coarse resolution (>10 km) soil moisture data. It is essential, however, to multilaterally analyze how various hydrological and environmental factors affect the backscattering coefficient, to utilize the data. In this study, soil moisture estimated by WCM (Water Cloud Model) and linear regression is compared with in-situ soil moisture data at 5 soil moisture observatories in the Korean peninsula. WCM shows suitable estimates for observing instant changes in soil moisture. However, it needs to be adjusted in terms of errors. Soil moisture estimated from linear regression shows a stable error range, but it cannot capture instant changes. The result also shows that the effect of soil moisture on backscattering coefficients differs greatly by land cover, distribution of vegetation, and water content of vegetation, hence that there're still limitations to apply preexisting models directly. Therefore, it is crucial to analyze variable effects from different environments and establish suitable soil moisture model, to apply SAR to water resources fields in Korea.

Analysis on Spectral Regrowth of Bandwidth Expansion Module by Quadrature Modulation Error in Digital Chirp Generator (디지털 첩 발생기에서의 직교 변조 오차에 의한 대역 확장 모듈에서의 스펙트럴 재성장 분석)

  • Kim, Se-Young;Sung, Jin-Bong;Lee, Jong-Hwan;Yi, Dong-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.761-768
    • /
    • 2010
  • This paper presents an effective method to achieve the wideband waveform for high resolution SAR(Synthetic Aperture Radar) using the frequency multiplication technique. And also this paper analyzes the root causes for the spectral regrowth due to 3rd-order intermodulation in chirp bandwidth expansion scheme using quadrature modulator and frequency multipliers. The amplitude and phase imbalance requirement are defined based on the simulation results in terms of quadrature channel imbalance. This minimizes the degradation of range resolution, peak sidelobe ratio and integrated sidelobe ratio. The wideband chirp generator using the frequency multiplier and memory map scheme was manufactured and the compensation technique was presented to reduce the spectral regrowth of SAR waveform by minimizing the amplitude and phase imbalance. After I and Q channel imbalance adjustment, the carrier level reduces -28.7 dBm to -53.4 dBm. Chirp signal with 150 MHz bandwidth at S-band expands to 600 MHz bandwidth at X-band. The sidelobe levels are reduced by about 8 to 9 dB by compensating the amplitude balance between I and Q channels.

A Study on the Correlation with the Degree of Compaction and the Penetration Depth Using the Portable Penetration Meter at Field Test (휴대용 다짐도 측정기의 현장실험을 통한 다짐도와 관입깊이 상관성 연구)

  • Park, Geoun Hyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.5-14
    • /
    • 2018
  • Worldwide, soil compaction work is one of the most important activities that are carried out on civil engineering works sites. Compaction work, particularly in the area of road construction, is considered to be important, as poor compaction work is closely related with poor construction even after a construction is complete. Currently, the plate bearing test or the sand cone method relative to the unit weight of soil test are commonly used to measure the degree of compaction, but as these require a great deal of time, equipment and manpower, it is difficult to secure economic efficiency. The method that is used to measure the degree of compaction according to the penetration depth achieved by free fall objects through gravity is the Free-Fall Penetration Test (FFPT), which uses a so-called "portable compaction measuring meter (PCMM)." In this study, the degree of compaction was measured and a penetration depth graph was developed after the field test using the portable compaction measuring meter. The coefficient of determination was 0.963 at a drop height of 10 cm, showing the highest level of accuracy. Both horizontal axis and longitudinal axis were developed in a decimal form of graph, and the range of allowable error was ${\pm}1.28mm$ based on the penetration depth. The portable compaction measuring meter makes it possible to measure the degree of compaction simply, quickly and accurately in the field, which will ensure economic efficiency and facilitate the process management.

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

An Analysis of Coherence and Resilience Depending on Materials Mixing Ratio in Elastic Landscape Pavement (조경용 탄성포장의 재료 배합비에 따른 결합력과 탄성분석)

  • Park, Won-Kyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5
    • /
    • pp.93-101
    • /
    • 2010
  • The demand for elastic pavement, providing comfort for pedestrians is expected to increase continuously but the lack of a standard for materials mixing ratio, that is, the optimal mixing ratio between ERDM chip and polyurethane binder, is still in a trial and error stage. This study aimed at recommending an optimal mixing ratio for elastic landscape pavement through a coherence and resilience test depending on ratio. The test result is outlined as follows. In a tensile strength test, samples B and C indicated a close positive relationship between the binder mixing ratio and tensile strength, indicating that the higher the mixing ratio the higher the tensile strength. In a hardness test, none of samples A, B or C indicated a statistical interrelationship between the binder mixing ratio and hardness. That is, the hardness of the elastic pavement material remained unchanged, irrespective of the binder mixing ratio. In a resilience lest, Samples A and B indicated a close negative interrelation between mixing ratio and resilience, indicating that the higher the mixing ratio, the lower the resilience. Upon analyzing the optimal mixing ratio based on test results, an increase in tensile strength began to slow at a 20% mixing ratio, while resilience began to reduce rapidly at 22%, Thus the optimal range for a mixing ration appeared to be 20~22%. The outcome of this study could to provide guidance for improving the elasticity and stability of elastic pavement.

A Design and Implementation of Busbar Joint and Temperature Measurement System (부스바 접촉 상태 및 온도 감지 시스템 설계 및 구현)

  • Lee, Young-dong;Jeong, Sung-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.379-385
    • /
    • 2017
  • In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact between busbar, deterioration of the contact resistance, over temperature of the busbars. In this paper, we designed and implemented the busbar joint and temperature measurement system, which can measure the joint resistance of busbar and loose connection between busbar using potentiometer and non-contact infrared sensor. The experimental results show that tightening the bolt and nut is fully engaged, resistance was decreased and maximum error range was 0.1mm. Also, the experimental result showed that the temperature at the contact area is increased from $27.3^{\circ}C$ to $69.3^{\circ}C$by the contact resistance.