The current spectral shape matching method (SSMM), developed by Ahn and Shanmugam (2004), relies on the assumption that the path radiance resulting from scattered photons due to air molecules and aerosols and possibly direct-reflected light from the air-sea interface is spatially homogeneous over the sub-scene of interest, enabling the retrieval of water-leaving radiances ($L_w$) from the satellite ocean color image data. This assumption remains valid for the clear atmospheric conditions, but when the distribution of aerosol loadings varies dramatically the above postulation of spatial homogeneity will be violated. In this study, we present the second version of SSMM which will take into account the horizontal variations of aerosol loading in the correction of atmospheric effects in SeaWiFS ocean color image data. The new version includes models for the correction of the effects of aerosols and Raleigh particles and a method fur computation of diffuse transmittance ($t_{os}$) as similar to SeaWiFS. We tested this method over the different optical environments and compared its effectiveness with the results of standard atmospheric correction (SAC) algorithm (Gordon and Wang, 1994) and those from in-situ observations. Findings revealed that the SAC algorithm appeared to distort the spectral shape of water-leaving radiance spectra in suspended sediments (SS) and algal bloom dominated-areas and frequently yielded underestimated or often negative values in the lower green and blue part of the electromagnetic spectrum. Retrieval of water-leaving radiances in coastal waters with very high sediments, for instance = > 8g $m^{-3}$, was not possible with the SAC algorithm. As the current SAC algorithm does not include models for the Asian aerosols, the water-leaving radiances over the aerosol-dominated areas could not be retrieved from the image and large errors often resulted from an inappropriate extrapolation of the estimated aerosol radiance from two IR bands to visible spectrum. In contrast to the above results, the new SSMM enabled accurate retrieval of water-leaving radiances in a various range of turbid waters with SS concentrations from 1 to 100 g $m^{-3}$ that closely matched with those from the in-situ observations. Regardless of the spectral band, the RMS error deviation was minimum of 0.003 and maximum of 0.46, in contrast with those of 0.26 and 0.81, respectively, for SAC algorithm. The new SSMM also remove all aerosol effects excluding areas for which the signal-to-noise ratio is much lower than the water signal.
This study is aimed to find out distribution status of online-market livestock products by purchasing and examining 120 cases of livestock products (seasoned meat: 17, 33 cases of packaged meat, 23 cases of ground meat, 19 cases of ham, 11 cases of sausage, 4 cases of bacon, 1 case of meat processing, 8 cases of Meat extract processed, and 4 cased of Dry storage of meat) at 17 On-line markets from April to August. 2015. We checked the weight of them first, and carried out ingredients test for each of processed meats. And we performed gene screening test on the products which were labelled 'Hanwoo' to investigate that the products were made of Korean native cattle. we also carried out test of identifying domestic animal species on ham, sausage and ground processed products. After weighing all products, we could know that all of them were delivered more than labelled weight or in allowable error. The result values of test which measured level of preservatives, Nitrite, Volatile Basic Nitrite (VBN), and tar Color by the type of processed meat products were in permissible range or not detected. Also, 17 beefs inspected Korean native cattle gene test were confirmed that they were made by real korean native cattle. But 2 cases of Ham, sausage, and ground processed products had difference between label and goods. In this study, we could make a decision that livestock products, distributed in On-line markets, were safe and expect to make higher degrees of hygiene for livestock products seller. Futhermore, we hoped result of this study could be used by basic data for progressive national policy decisions.
수자원의 추가 확보와 홍수에 대한 선제적 대응을 목적으로 국내 4대강 주요 지점에 다기능보(multi-function weir)를 설치하였다. 다기능보는 흐름 통제 단면으로서 정밀한 유량 산정이 가능한 수리구조물로 하천의 일반적인 수위-유량 관계식보다 정밀하게 산정할 수 있으며, 향후 각 유역의 국가 표준 유량 기준점으로 활용할 수 있는 방안을 강구하는 것이 바람직하다. 이에 본 연구에서는 영산강의 승촌보를 대상으로 현재 취득되는 운영 자료를 분석하여 개선사항을 제시하고, 이를 보완하기 위하여 간접유량추정 방법인 경사-면적법(slope-area method)을 응용하여 정밀한 유량 산정이 가능할 수 있는 방법을 제안하고자 한다. 분석 결과, 현재 상태는 이론적인 유량계수 범위 초과와 급격한 변동, 상 하류부의 수위차를 연동하지 못하는 등 이에 대한 보완이 필요하였다. 응용한 경사-면적법은 앞서 제시한 한계점을 보완하고, 자연 하도의 검증된 수리학적 이론에 의해 수면경사와 마찰손실을 반복 계산을 통해 오차를 줄여나가는 상호 보완적인 방법으로 물리적으로 타당하여 적용가능성을 확인하였다. 향후, 다기능보의 최적 운영을 위하여 이를 적용한다면, 실제 운영에 도움이 될 것으로 기대된다.
Objectives: We investigated the safty of distilled Astragali Radix Herbal Acupuncture, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture on vital sign -BP, pulse, resperation-in adult man. Methods : We investigated on 106 healthy volunteers consisted of each 30 subjects in experiment (distilled Astragali Radix Herbal Acupuncture, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture) group and 30 subjects in control(Normal Saline) group. Study form was a randomized, placebo-controlled, double-blind clinical trial. 30 subjects in each experiment group were injected distilled Astragali Radix Herbal Acupuncture, Wild Ginseng Herbal Acupuncture, Rehmannia glutinosa Herbal Acupuncture at $GB_{21}$(Kyonjong) and 30 subjects in control group were injected Normal Saline at $GB_{21}$ (Kyonjong). except of 2 subjects(in control group) who can't be measured and 10 subjects(6 in experiment group and 4 in control group) who move or make unforceable error during measuring. Finally each 25. subject, subject, subject in experiment group and 24 subject in control group are studied. We measured resperation by PolyG-I and BP & pulse by electric manometer on 5 times : before injection per 5 minutes during and after injection per 10 minutes during 35 minutes. The SPSS 13.0 for windows was used to analyze the data and the Student t test(between two groups) were used to verify the result. Results : 1. After distilled Astragali Radix Herbal Acupuncture injection, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture , systolic BP is not significantly change in all experiment time. 2. After distilled Astragali Radix Herbal Acupuncture injection, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture , diastolic BP is not significantly change in all experiment time. 3. After distilled Astragali Radix Herbal Acupuncture injection, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture , pulse is not significantly change in all experiment time. 4. After distilled Astragali Radix Herbal Acupuncture injection, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture , resperation is not significantly change in all experiment time. Conclusions : The results suggest that distilled Astragali Radix Herbal Acupuncture, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture in healthy adult man don't influence vital sign within normal range. This result is derived from that distilled Astragali Radix Herbal Acupuncture, Wild Ginseng Herbal Acupuncture and Rehmannia glutinosa Herbal Acupuncture in healthy adult man are safety.
Digora/sup (R)/ an intraoral digital radiography system utilizing image plate (IP) - has a dynamic range of exposure time which allows it to decrease the patient's exposure time and to increase diagnostic ability through image processing, transmission and storage. The purpose of this study was to evaluate the Digora/sup (R)/ system by assessing the effects of various exposure times on the detectability on the tip of the endodontic file. Examining the root canals of 45 extracted sound premolars, K -files No. 10, 15, and 20 were placed at slightly varying distances from the apex. The teeth were glued onto resin-plaster blocks. Five exposure times varying between 0.01 seconds and 0.25 seconds were used. Four observers were asked to measure the distance between the tip of the file and a reduction of crown portion, and obtained mean errors (subtracting true file length from the measured file length), comparing Digora/sup (R)/ monitors with E-plus films, which were both obtained under the same geometrical positions. The results were as follows : 1. Comparing E-plus film with Digora/sup (R)/ at 0.01 seconds, the mean errors in E-plus film showed -4.453 nun, -4.497 nun, and -3.857 nun, while the mean errors in Digora/sup (R)/ showed 0.065 nun, 0.607 nun, and 0.719 mm according to the file groups. Therefore there was a significant difference between E-plus film and Digora/sup (R)/(p<0.05). 2. By comparison of mean errors according to the various exposure times in the Digora/sup (R)/ system, the mean error at 0.01 seconds was significantly lower than that at 0.12 and 0.25 seconds in the No. 10 file group(p<0.05). And the standard deviation was the highest at 0.01 seconds. 3. Comparing E-plus film at 0.25 seconds with the Digora/sup (R)/ system, the mean errors showed a significant difference between E-plus film at 0.25 seconds and the Digora/sup (R)/ system at 0.25 seconds in No. 10 and 20 file groups(p<0.05). 4. Comparing E -plus film at 0.25 seconds with other exposure times, the mean errors showed a significant difference between E-plus film at 0.25 seconds and E-plus film at 0 .. 01 and 0.03 seconds in 10 file group(p<0.05). In the No. 15 and 20 file groups, there was a significant difference between E-plus film at 0.25 seconds and E-plus film at 0.01 seconds(p<0.05). In conclusion, Digora/sup (R)/ was better than E-plus film in detectability on the tip of the file at the exposure time of 0.01 seconds in all file groups. And we concluded that Digora/sup (R)/ can shorten exposure times up to 4% of 0.25 seconds (0.01 sec), which is adequate exposure time for premolar in E-plus film using No. 15 and 20 files.
1997년 우리나라에서 무인과속단속시스템 32대가 처음 도입된 이래 2008년 1월 현재 약 3,700기가 설치되어 운영 중에 있으며, 이는 운전자의 운전행태 및 교통특성 변화를 유도함으로서 교통안전을 개선시켜 결과적으로 교통사고건수 및 사망자 수를 크게 감소시키는 것으로 나타났다. 그러나 현재의 설치효과 평가방법은 설치전후 각 1년간 단순 비교하는 방법으로, 설치 바로 전년도의 교통사고건수가 다른 요소에 의해 최근 몇 년간 발생건수에 의해 급격히 증가(감소)하였을 경우 시스템 설치 후 감소(증가)되었어도 명확히 시스템 설치 효과라고 단정 짓기 어려운 실정이다. 본 연구에서는 시스템 설치전후 4단계 분석기법을 근간으로 하여 과속단속시스템의 설치효과에 대하여 새롭게 평가하였다. 그 결과 2006년도에 설치한 205대의 과속단속시스템 설치효과는 기존의 분석방법에서 제시한 18%의 교통사고건수 감소효과가 아니라 시스템 설치효과에 의해 $27.4{\pm}3%$, 도로개선 등 기타 요인으로 인한 오차범위가 ${\pm}12.89%$인 것으로 나타났다.
본 논문은 고속도로 톨게이트에서 통행 요금징수로 인해 교통지체가 발생할 때 이를 최소화하기 위해 자동요금징수시스템을 설치하는 경우 차량들의 통과시간이 어떻게 변화하는지 분석한 연구결과를 제시하고 있다. 본 연구에서는 이 설치효과를 톨게이트를 빠져나가는 차량들의 통과시간 감소 편익이라고 생각했으며, 차량의 통과시간을 분석하기 위해 다중서비스 대기행렬 이론을 적용해서 분석하였다. 본 연구에서 분석한 결과, 톨게이트로 진입하는 차량들의 입차 간격이 Poisson 분포를 따르고, 자동요금징수시스템의 서비스 시간이 지수 분포를 따를 때 다중서비스 대기행렬이론을 적용하여 차량들의 통과시간을 분석하는 것이 바람직하다는 것과, 자동요금징수시스템을 설치하더라도 통행 요금을 징수하는데 걸리는 시간이 다르기 때문에 톨게이트 출구 쪽이 입구 쪽보다 통과시간 감소효과가 더 크게 나타난다는 것, 그리고 자동요금징수시스템을 설치한다고 해서 항상 톨게이트를 통과하는 시간이 감소하는 것은 아니며, 자동요금징수시스템 차로에 너무 많은 차량들이 몰리는 경우 오히려 톨게이트 전체로 볼 때는 차량당 통과시간이 증가한다는 것을 밝혔다. 끝으로 본 연구에서는 다중서비스 대기행렬이론의 정확성을 판단하기 위해 실제로 톨게이트 현장조사에서 통과 차량들의 평균 통과시간을 조사해서 모형 값과 비교했는데, 그 결과 모형 값과 실측 값은 약 1~3초 정도의 미소한 차이만을 보여서 다중서비스 대기행렬이론을 실무에 적용해도 좋다는 결론을 얻었다.
상업용 12인치 급속가열장치(RTP)의 다변수 고급제어기를 개발하기 위하여 열전대가 부착된 웨이퍼를 대상으로 다변수 모델인식을 수행하였다. 웨이퍼에는 7개의 열전대가 설치되어 있으며 10개의 텅스텐-할로겐 램프 그룹으로 가열을 할 수 있다. 모델인식 실험과정에서 웨이퍼의 휨을 최소화하며 최종적으로 10-입력 7-출력의 균형 잡힌 상태공간 모델을 얻기 위한 모델인식방법을 제안하였다. 또한 넓은 온도영역에서 복사에 의한 비선형성을 가장 효과적으로 상쇄시킬 수 있는 출력변수 정의방법을 제안하였다. 600, 700, $800^{\circ}C$ 부근의 정상상태에서 실험을 수행하여 모델을 추정한 결과 상태의 차수는 80~100, 모델출력은 $y=T(K)^2$으로 결정하는 것이 바람직하며, 이때 one-step-ahead 온도예측 오차의 제곱평균은 0.125~0.135 K 정도로 나타났다.
DASH는 네트워크 상황에 따라 클라이언트가 서버에게 멀티미디어 콘텐츠를 요청하고 이를 이용하여 멀티미디어 콘텐츠를 전송하는 적응형 스트리밍 기술이다. 이러한 구조에서 멀티미디어 콘텐츠 사용자에게 최선의 품질을 보장하기 위해서는 정확한 가용 대역폭 측정이 필요하다. 그런데 TCP의 전송 특성을 고려하지 않는 DASH는 이전 미디어 세그먼트 크기에 따라 측정된 가용 대역폭이 다르고 때문에 사용자에게 QoE를 보장하기 어렵다. 본 논문은 TCP Slow start구간을 가용 대역폭 측정에서 배제하여 가용대역폭 측정 오류를 줄이는 새로운 dash대역폭 측정 방법을 제안한다. 제안 방법은 이전 세그먼트 크기에 따라 가용 대역폭 측정의 결과가 달라지는 문제를 해결할 수 있다. 우리가 제안하는 가용 대역폭 측정 방법을 오픈 소스 기반 DASH시스템에서 구현하여 기존 대역폭 측정 방법과 성능을 비교 평가하였다. 성능 평가 결과 제안 방법은 기존 대역폭 측정 방법에 비해 정확도가 20% 향상되었다. 또 평균 세그먼트 서비스 품질, 세그먼트 품질 변경 횟수 등의 측면에서 사용자 QoE가 개선됨을 확인하였다.
연약지반에 축조되는 구조물 설계에 매우 중요한 지반 특성치인 점토지반의 비배수 전단강도를 깊이에 따라 연속적으로 측정할 수 있는 현장 원위치 시험법으로서 피에조 콘의 활용도가 점점 높아지고 있다. 피에조 콘 시험으로 추정되는 비배수 강도의 신뢰성은 이에 적용되는 콘 계수 값의 신뢰성에 크게 의존한다. 콘 계수에 대한 여러 연구자들의 제안이 우리의 실정에 맞는지 검증하고 점토지반의 특성에 따른 콘 계수 값의 변화 특성을 파악하여 콘 계수 선정에 대한 합리적인 기준을 마련하는 것이 이 연구의 목적이다. 이 연구는 경남 양산물금 지역의 해성점토층을 대상으로 피에조 콘 시험과 비교란 시료에 대한 실내 전단강도시험(일축압축시험, 비압밀 비배수 삼축압축시험)과 압밀시험을 실시하였다. 시험 결과를 이용하여 콘 계수와 점토의 여러 역학적 특성치(비배수 전단강도, 선행압밀압력, 소성지수, 간극수압비, 강성지수, 마찰비)의 관계를 고찰하여 콘 계수 값의 합리적 선정을 위한 기준을 마련하고자 하였다. 연구 결과로부터 얻은 결론으로서는, 상관관계가 비교적 높은 특성치의 짝은 비배수 전단강도와 콘 계수$(N_{kt}, N_{ke}, N_{\Delta u})$, 선행압밀압력과 $(N_{kt}, N_{ke})$, 간극수압비(B$_{q}$ )와 $(N_{ke}, N_{\Delta u})$이었고 선행압밀압력과 $(N_{\Delta u}), B_q와 (N_{kt})$는 상관 관계가 나타나지 않았으며, 소성지수, 강성지수, 그리고 마찰비도 콘 계수와 상관 관계가 없는 것으로 나타났다. 또한, 비압밀 비배수(UU) 삼축압축시험으로 구한 점토의 비배수 전단강도를 기준으로 할 때, 여러 제안자들이 제안한 피에조 콘 시험결과를 이용한 비배수 전단강도 추정에서 $(N_{\Delta u})$가 다른 두개의 콘 계수보다 선행압밀압력의 크기에 상관없이 변화폭, 표준편차 및 분산도가 모두 작아서 신뢰성이 가장 높게 나타났다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.