• 제목/요약/키워드: error range

검색결과 2,811건 처리시간 0.025초

슬라이딩 모드를 이용한 HYBRID PID형 퍼지제어기 (HYBRID PID FLC using sliding Mode)

  • 문준호;조종훈;오광현;김태언;남문현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.992-994
    • /
    • 1995
  • FLC has a good performance for complication system or unknown model by using human linguistic method but many part control design are based on expert knowledge or trial-error method and it is difficult to prove stability and robustness of controller. In this paper we improve this problem by setting fuzzy rules by dividing phase plane of error and rate of error change by switching surface. We can guarantee the stability in nonlinear system, and also in fuzzy PID type controller the complexity of controller design is increased by increasing the number of input variables and defining more range of operation if we want performance of more specific rules, thus we need to fine the method to decrease the number of control rules used in FLC design. In this paper the algorithm is validated by simulation using conventional FLC and proposed method.

  • PDF

Structured Light 기법을 이용한 이동 로봇의 상대 위치 추정 알고리즘 연구 (A Study on the Relative Localization Algorithm for Mobile Robots using a Structured Light Technique)

  • 노동기;김곤우;이범희
    • 제어로봇시스템학회논문지
    • /
    • 제11권8호
    • /
    • pp.678-687
    • /
    • 2005
  • This paper describes a relative localization algorithm using odometry data and consecutive local maps. The purpose of this paper is the odometry error correction using the area matching of two consecutive local maps. The local map is built up using a sensor module with dual laser beams and USB camera. The range data form the sensor module is measured using the structured lighting technique (active stereo method). The advantage in using the sensor module is to be able to get a local map at once within the camera view angle. With this advantage, we propose the AVS (Aligned View Sector) matching algorithm for. correction of the pose error (translational and rotational error). In order to evaluate the proposed algorithm, experiments are performed in real environment.

RGPS를 이용한 실시간 차량관제시스템 구현과 오차분석 (Development of real-time car tracking system with RGPS and its error analysis)

  • 고선준;이자성
    • 제어로봇시스템학회논문지
    • /
    • 제6권1호
    • /
    • pp.15-24
    • /
    • 2000
  • Stand-alone global position system receiver based on C/A code tracking generates position error of 100m mainly due to the selective availability and ionospheric and tropospheric delay errors. The differential GPS is the most commonly used method for removing those bias range error components. The relative GPS, although somewhat restrictive in its use, is ideally suited to the car monitoring system for improved Automatic Vehicle location, especially where the DGPS infrastructure is not available. The RGPS does not require any additional hardware, facility or external infrastructure and can be operated within the system with existing host computer and communication link. This paper presents detailed description of the RGPS concept and its implementation for real-time data processing. Performance of RGPS is evaluated with real data and is compared with DGPS.

  • PDF

핵증기 발생기의 9룰 퍼지논리 제어기 (A 9-Rule Fuzzy Logic Controller of the Nuclear Steam Generator)

  • Lee, Jae-Young;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.371-380
    • /
    • 1993
  • 운전원의 언어적인 제어 논리를 이용한 모델과 무관한 제어기가 증기 발생기의 수위 제어를 위해 개발되었다. 오직 9개의 룰을 수위 오차와, 응축 수위 변화를 표현하는 유량 오차로부터 얻어졌다. 벨형의 소속함수는 민감도 분석을 통하여 조절되었고, 결과 과도 상태와 정상상태 공히 양호한 제어성능을 보였다. 저출력에서 전 출력까지의 다단계 출력 증가에 대하여, 전 운전 영역에서 좋은 제어를 보였다.

  • PDF

근적외분광분석법을 이용한 인도메타신의 정량분석 (Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

GAIA PARALLAX ZERO POINT FROM RR LYRAE STARS

  • Gould, Andrew;Kollmeier, Juna A.
    • 천문학회지
    • /
    • 제50권1호
    • /
    • pp.1-5
    • /
    • 2017
  • Like Hipparcos, Gaia is designed to give absolute parallaxes, independent of any astrophysical reference system. And indeed, Gaia's internal zero-point error for parallaxes is likely to be smaller than any individual parallax error. Nevertheless, due in part to mechanical issues of unknown origin, there are many astrophysical questions for which the parallax zero-point error ${\sigma}({\pi}_0)$ will be the fundamentally limiting constraint. These include the distance to the Large Magellanic Cloud and the Galactic Center. We show that by using the photometric parallax estimates for RR Lyrae stars (RRL) within 8kpc, via the ultra-precise infrared period-luminosity relation, one can independently determine a hyper-precise value for ${\pi}_0$. Despite their paucity relative to bright quasars, we show that RRL are competitive due to their order-of-magnitude improved parallax precision for each individual object relative to bright quasars. We show that this method is mathematically robust and well-approximated by analytic formulae over a wide range of relevant distances.

유전체 코호트 연구의 주요 통계학적 과제 (Statistical Issues in Genomic Cohort Studies)

  • 박소희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제40권2호
    • /
    • pp.108-113
    • /
    • 2007
  • When conducting large-scale cohort studies, numerous statistical issues arise from the range of study design, data collection, data analysis and interpretation. In genomic cohort studies, these statistical problems become more complicated, which need to be carefully dealt with. Rapid technical advances in genomic studies produce enormous amount of data to be analyzed and traditional statistical methods are no longer sufficient to handle these data. In this paper, we reviewed several important statistical issues that occur frequently in large-scale genomic cohort studies, including measurement error and its relevant correction methods, cost-efficient design strategy for main cohort and validation studies, inflated Type I error, gene-gene and gene-environment interaction and time-varying hazard ratios. It is very important to employ appropriate statistical methods in order to make the best use of valuable cohort data and produce valid and reliable study results.

하이포이드 기어의 소음원인규명을 위한 디플렉션 테스트와 전달오차 측정에 대한 연구 (Identify Hypoid Gear Whine Noise for Deflection Test and Transmission Error Measurement)

  • 최병재;오재응;박상길
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.127-137
    • /
    • 2009
  • Hypoid gears are widely used in rear drive and 4WD vehicle axles. Investigation of their sensitivity to deflections is one of the most important aspects of their design and optimization procedures. The deflection test is performed in the actual gear mounting using completely processed gear. This test should cover the full operating range of gear loads from no load to peak load. Under peak load the contact pattern should extend to the tooth boundaries without showing a concentration of the contact pattern at any point on the tooth surface. Transmission error is tested on an axle assembly triaxial real car load condition.

상관 영역과 초당 촬영 수와 해상도에 따른 Granular PIV에서의 유동 속도의 오차 분석 (Error Analysis of Flow Velocity Measured through Granular PIV Based on Interrogation Area, Frame Per Second, and Video Resolution)

  • 최종은;박준영
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.58-65
    • /
    • 2021
  • Research on general particle image velocimetry (PIV) has been conducted extensively, but studies on granular PIV are relatively insufficient. In addition, the parameters used for analyzing granular PIV need to be optimized. In this study, we analyzed the error of velocity measurements based on the interrogation area (64-192 pixel), frame per second (30-120 FPS), and video resolution [ultrahigh definition (UHD) and high definition (HD)] within the velocity range typically measured in hoppers. The estimated errors of the granular PIV were below 5%, which is generally acceptable. However, considering the data reliability, the flow velocity in the hopper could be measured with less than 5% error at 120 FPS or higher in the HD resolution and 30 FPS or higher in the UHD resolution.

항공 기관총 구동제어 감속기용 저토크 고정밀 자동 백래시 측정장치 개발 (Low Torque High Precision Automatic Backlash Measuring System for Aircraft Machine Gun Control Reducer)

  • 박태현
    • 한국기계가공학회지
    • /
    • 제21권7호
    • /
    • pp.34-42
    • /
    • 2022
  • Minimizing the backlash of gears and reducers is important for their proper and precise functioning. In this study, an automatic backlash measuring system was developed for the mass production and quality control of a military-grade reducer. The developed automatic backlash measurement system eliminates human error during the backlash measurement process. It also reduces the manufacturing time and digitizes the backlash number. The system was tested for an aircraft machine gun control reducer that required low-torque and high-precision conditions. The test results show that the torque range was 0.820-4.788 Nm. The maximum torque error is less than 0.231 N·m at 2.943 N·m, and 1.2 arcmin of the maximum backlash error with ± 0.3 arcmin of repeatability. The developed system satisfies all required conditions: torque of 1-3 Nm, torque accuracy within ± 0.5 N·m, and backlash accuracy of ± 3 arcmin.