• Title/Summary/Keyword: error range

Search Result 2,811, Processing Time 0.032 seconds

AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT (인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사)

  • Park Chang-Seo;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF

Analysis for the Squareness Measurement using Laser Interferometer (레이저 간섭계를 이용한 직각도 측정에 관한 분석)

  • Lee, Dong-Mok;Lee, Hoon-Hee;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.863-872
    • /
    • 2012
  • The squareness measurement of driving axes of a machine tool is very important to evaluate the performance of the machine. Laser interferometer measurement system is one of the most reliable equipment to measure the squareness. However, squareness measurement using laser system with an optical square result in restriction of straightness optics setup and Abbe's offset. This offset combines with angular errors during the motion of an axis to cause Abbe's error. In addition, the difficulty in optical square setup causes restriction of other optics and limitation of measurable range. In this paper, mathematical approaches are presented to eliminate the Abbe's error and to estimate squareness for full range by using the best fit of straightness data measured without an optical square. Experiments for squareness measurement of 3 axis machine tool were conducted and the proposed techniques were used for squareness evaluation with elimination of Abbe's error and squareness estimation for the full travel range.

A Real Time Measurement of Ice Concentration of Ice Slurry in Pipe (배관내 흐르는 아이스슬러리의 실시간 얼음분율 측정)

  • Jung, Hae-Won;Peck, Jong-Hyeon;Kim, Yong-Chan;Kang, Chae-Dong;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.599-606
    • /
    • 2007
  • An experimental study was performed to measure a ice concentration of ice slurry flowing in a pipe in a real time. In the present paper, we suggested a measuring method by a refractive index and compared it to other methods by a freezing point and a density. To measure the refractive index of the solution, ice particles in the ice slurry should be completely removed and a hydro-cyclone was introduced instead of a mesh. The measuring method through the refractive index coincided with the density method using the real-time solution density within ${\pm}5%$ error range, having the error range less than the other two methods. In the other hand, the measuring method through the density has a good resolution, but the result using the initial density of the solution was different more than 10% error from that using the real-time density. And it has an error range 1.5 times greater than the method through the refractive index.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

A Compensation of Color Eerror Caused by Dynamic Range Transformation of Images (생동도 변환으로 인한 화상의 색오차 보정)

  • 장종국;권기룡;안상호;송규익;이건일
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.124-130
    • /
    • 1996
  • A compensation method of color error resulting from dynamic range transformation of color image is propsoed. The color error is measured using the CIE L a b uniform color space, and the color image is compensated to minimize it. The color error is significant in the dark region of image, which is caused by the lunimance scaling factor is relatively large in that case. In the proposed method, we weight the luminance scaling factor corresponding to luminnce to minimize the error. Because the weighting factor depends on luminace distribution of image, a decisio method of weighting factor using histogram is also proposed.

  • PDF

DAWAST Model Considering the Phreatic Evaporation in the Frozen Region (동결기 자유수면 지하수의 모관상승량을 고려한 DAWAST 모형)

  • 김태철;박철동
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.78-84
    • /
    • 2001
  • The daily streamflow in the Yaluhe watershed located in the north-eastern part of China was simulated by DAWAST model and the water balance parameters of the model were calibrated by simplex method. Model verification tests were carried out. The range of root mean square error was 0.34∼1.50mm, that of percent error in volume was -16.9∼-62.0% and that of correlation coefficient was 0.727∼0.920. DAWAST model was revised to consider the phreatic evaporation from the ground water in the frozen soil by adjusting soil moisture content in the unsaturated layer at the end of the melting season. The results of estimation of the daily streamflow by the revised model were statistically improved, that is, the range of root mean square error was 0.31∼1.49mm, that of percent error in volume was -11.7∼-12.1%, and that of correlation coefficient was 0.810∼0.932. The accuracy of DAWAST model was improved and the applicability of DAWAST model was expanded to the frozen region.

  • PDF

A GPS/DR Integration Scheme using Carrier Measurements (반송파 정보를 이용한 GPS/DR 통합 방법)

  • Seo, Hung-Seok;Sung, Tae-Kyung;Lee, Sang-Jeong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1279-1286
    • /
    • 1999
  • In conventional GPS/DR integration schemes, the GPS position (or pseudo-range) information is used in calibrating DR sensors. In those schemes, however, an inaccurate calibration may degrade the position accuracy when the GPS measurement is not available. This paper presents a new integration scheme where the GPS velocity information is used in calibrating DR sensors. Also proposed is a new error model of DR sensors for calibrating the bias error and the tilt error in dynamic environments. The proposed model makes it possible that the errors of both the DR sensor parameters and the velocity are calibrated using the GPS carrier-based velocity(or the pseudo-range rate) measurement while the DR position error is calibrated using the GPS position measurement. Since the DR sensors are calibrated accurately, the positioning accuracy is drastically improved when the GPS measurements are unavailable.

  • PDF

TEMPORAL ERROR CONCEALMENT ALGORITHM BASED ON ADAPTIVE SEACH RANGE AND MULTI-SIDE BOUNDARY INFORMATION FOR H.264/AVC

  • Kim, Myoung-Hoon;Jung, Soon-Hong;Kang, Beum-Joo;Sull, Sang-Hoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.273-277
    • /
    • 2009
  • A compressed video stream is very sensitive to transmission errors that may severely degrade the reconstructed image. Therefore, error resilience is an essential problem in video communications. In this paper, we propose novel temporal error concealment techniques for recovering lost or erroneously received macroblock (MB). To reduce the computational complexity, the proposed method adaptively determines the search range for each lost MB to find best matched block in the previous frame. And the original corrupted MB split into for $8{\times}8$ sub-MBs, and estimates motion vector (MV) of each sub-MB using its boundary information. Then the estimated MVs are utilized to reconstruct the damaged MB. In simulation results, the proposed method shows better performance than conventional methods in both aspects of PSNR.

  • PDF

A Case Study On The Suitability Of Drawings Through Application Of BIM In Construction Management (건설사업관리 분야에서 BIM적용을 통한 도서의 적합성 검토 사례)

  • Park, Young-Jin;Song, Kyung-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.33-34
    • /
    • 2017
  • The purpose of this case study is to reduce the flaw and reconstruction occur at the level of construction by determining the propriety of estimate and error on a drawing and specification at working design level through case studies of BIM application at the level of design review. As a preliminary to apply BIM technology, it is needed to review the drawing, and then it is required to define BIM range by selecting the section in which construction error occurs frequently except for the type of part that is constructed repeatedly. At the execution level, the drawing is reviewed vertically, horizontally and spatially by proceeding structure and finish modeling on the defined BIM range, and also the propriety of estimate and error on the drawing and specification are examined. We aim to raise the completion rate, improve quality of construction, reduce the cost for construction and shorten period of construction by preparing for the error on the drawing and specification in advance through this review procedures.

  • PDF

A Study on the Circular Error Probability of Short-Range Rocket with Parachute (낙하산을 갖는 단거리 발사체의 오차분석)

  • 김찬수;조요한
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.218-225
    • /
    • 1999
  • This paper contains the computational simulation of a free rocket with a parachute and the development of a firing table for each range. To obtain the trajectory of the rocket, 6 DOF model of rocket with parachute was generated and the wind tunnel test was done for the input parameters. Good agreement was obtained between the analysis of trajectory and the flight test result. Also the trajectory error analysis was performed by the Monte Carlo simulation. As a result of simulation, the CEP(Circular Error Probability) of the firing table was calculated.

  • PDF