• Title/Summary/Keyword: error range

Search Result 2,816, Processing Time 0.032 seconds

An Analysis on the Results of Cadastral Coordinate Computation of Urban Control Point for Connection to Cadastral Control Point -A Case Study of Changwon-si of Kyungnam- (지적기준점과 연계 활용을 위한 도시기준점의 지적좌표 성과산출 분석 - 경상남도 창원시를 중심으로-)

  • Hong, Sung-Eon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.127-138
    • /
    • 2011
  • This study aimed at suggesting the possibility of an application that connects cadastral control point and urban control point. In order to do this, we calculated and analyzed the cadastral coordinate on urban control point by using the GPS observation data of Changwon-si urban control point (32 points) which was announced based on the result of global coordinate system. We calculated cadastral coordinate through using three different kinds of calculation S/Ws, and compared the results of the calculation with the preexisting result of urban control point. The comparison suggested that the gap between the new results and the existing results is in the range of error specified by a law. Therefore, the result can be used in cadastral surveying. However, for the safe application in practical works, we suggested that it would be better to carry out new cadastral surveying and use its result than to use the result of the current urban control point directly in surveying cadastral. In addition, we suggested that it is necessary to examine precisely the local station of triangulation. Finally, we recommended that one should use trilateral network adjustment S/W as one's calculation S/W.

Effects of Chemical Contents Variation in Covered Barley Seed on Near Infrared Reflectance Spectroscopy (겉보리 종실 성분 변이가 근적외 분광분석치에 미치는 영향)

  • 김병주;박의호;정찬식
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.3
    • /
    • pp.354-361
    • /
    • 1996
  • Near Infrared Reflectance Spectroscopy(NIRS) is accepted as today's most versatile method for rapid chemical analysis. The technique offers rapid multicomponent analysis. This study was conducted to improve the efficiency of quality analysis in covered barley grain, and to search for the effects of chemical components variation in covered barley grain on NIRS. Among the three groups with different range in the contents, each equation for starch contents increased standard error of prediction(SEP) and increased correlation coefficient from 0.872 to 0.883. According as, $\beta$-glucan and protein contents decreased SEP and increased correlation coefficient by expanded chemical components variation. Effective equation for ash contents analysis was obtained from group 3. Among the covered barley chemical components, starch and ash contents were required to conduct futher studies in term of accuracy and variation of contents. It was concluded that NIRS method would be applicable for the rapid determination of $\beta$-glucan and protein contents in covered barley grains.

  • PDF

A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System (X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가)

  • Han, Dong-Kyoon;Ko, Shin-Gwan;Seon, Jong-Ryul;Yoon, Seok-Hwan;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

Determination of Phenobarbital in Intact Phenobabital Tablets using NIRS (근적외선 분광광도법을 이용한 페노바르비탈정제의 정량법에 관한 연구)

  • Cha, Ki-Won;Ze, Keum Ryon;Youn, Mi Ok;Lee, Su Jung;Choi, Hyun Cheol;Kim, Ho Jung;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.102-107
    • /
    • 2002
  • This paper describes a rapid determination of phenobarbital in intact phenobarbital tablets using partial least squares regression(PLSR) method of transmittance spectrum of near infrared (NIR) compared with the analytical data of liquid chromatograpy. The linearity, concentration range and precision of this analytical method are studied. The correlation coefficient of the calibration curve is 0.9983 and the standard error of calibration(SEC) is 0.14 %. Intra-day precision and Inter-day precision obtained in this method are CV = 0.45, CV =0.56, respectively.

Fuzzy-Neuro Controller for Speed of Slip Energy Recovery and Active Power Filter Compensator

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.480-480
    • /
    • 2000
  • In this paper, we proposed a fuzzy-neuro controller to control the speed of wound rotor induction motor with slip energy recovery. The speed is limited at some range of sub-synchronous speed of the rotating magnetic field. Control speed by adjusting resistance value in the rotor circuit that occurs the efficiency of power are reduced, because of the slip energy is lost when it passes through the rotor resistance. The control system is designed to maintain efficiency of motor. Recently, the emergence of artificial neural networks has made it conductive to integrate fuzzy controllers and neural models for the development of fuzzy control systems, Fuzzy-neuro controller has been designed by integrating two neural network models with a basic fuzzy logic controller. Using the back propagation algorithm, the first neural network is trained as a plant emulator and the second neural network is used as a compensator for the basic fuzzy controller to improve its performance on-line. The function of the neural network plant emulator is to provide the correct error signal at the output of the neural fuzzy compensator without the need for any mathematical modeling of the plant. The difficulty of fine-tuning the scale factors and formulating the correct control rules in a basic fuzzy controller may be reduced using the proposed scheme. The scheme is applied to the control speed of a wound rotor induction motor process. The control system is designed to maintain efficiency of motor and compensate power factor of system. That is: the proposed controller gives the controlled system by keeping the speed constant and the good transient response without overshoot can be obtained.

  • PDF

DEVELOPMENT OF THE THERMAL MODEL FOR KITSAT-1/2 MICROSATELLITES AND ITS VERIFICATION USING IN-ORBIT TELEMETRIES (우리별 1, 2호의 열제어 모델 개발 및 궤도 운용 결과를 바탕으로 한 모델의 검증)

  • 박성동;배정석;성단근;최순달
    • Journal of Astronomy and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.105-116
    • /
    • 1996
  • This study is based upon the thermal modeling, analysis and operational results of KITSAT-1 and KITSAT-2 microsatellites launched on August 11, 1992 and Septermber 26, 1993, respectively. As KITSAT-1/2 was designed to be launched as an auxiliary payload of ARIANE launcher, the constraints on volume, power consumption, and mass were required to adopt passive thermal control method controlling absorptivity, emissivity, and conductivities among adjacent modules. The main of KITSAT was to take Earth images using CCD cameras positioned at the bottom of spacecraft, in which the cameras were always pointing to the center of Earth. This study is concerned with orbital analysis, thermal modeling, simulation results, and its verification by utilizing in-orbit telemetry data of KITSAT-2. The results of telemetry analysis show that the thermal modeling is matched to actual temperature data within 10 degrees of error range in average.

  • PDF

Design of a Variable Sampling Rate Tracking Filter for a Phased Array Radar (위상배열 레이다를 위한 가변 표본화 빈도 추적 필터의 설계)

  • Hong, Sun-Mog
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.155-163
    • /
    • 1992
  • The phased array antenna has the ability to perform adaptive sampling by directing the radar beam without inertia in any direction. The adaptive sampling capability of the phased array antenna allows each sampling time interval to be varied for each target, depending on the acceleration of each target at any time. In this paper we design a three-dimensional adaptive tracking algorithm for the phased array radar system with a given set of measurement parameters. The tracking algorithm avoids taking unnecessarily frequent samples, while keeping the angular prediction error within a fraction of antenna beamwidth so that the probability of detection will not be degraded during a track update illuminations. In our algorithm, the target model and the sampling rate are selected depending on the target range and the target maneuver status which is determined by a maneuver detector. A detailed simulation is conducted to test the validity of our tracking algorithm for encounter geometries under various conditions of maneuver.

  • PDF

Comparison of Composite Methods of Satellite Chlorophyll-a Concentration Data in the East Sea

  • Park, Kyung-Ae;Park, Ji-Eun;Lee, Min-Sun;Kang, Chang-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.635-651
    • /
    • 2012
  • To produce a level-3 monthly composite image from daily level-2 Sea-viewing Wide Field-of-view Sensor (SeaWiFS) chlorophyll-a concentration data set in the East Sea, we applied four average methods such as the simple average method, the geometric mean method, the maximum likelihood average method, and the weighted averaging method. Prior to performing each averaging method, we classified all pixels into normal pixels and abnormal speckles with anomalously high chlorophyll-a concentrations to eliminate speckles from the following procedure for composite methods. As a result, all composite maps did not contain the erratic effect of speckles. The geometric mean method tended to underestimate chlorophyll-a concentration values all the time as compared with other methods. The weighted averaging method was quite similar to the simple average method, however, it had a tendency to be overestimated at high-value range of chlorophyll-a concentration. Maximum likelihood method was almost similar to the simple average method by demonstrating small variance and high correlation (r=0.9962) of the differences between the two. However, it still had the disadvantage that it was very sensitive in the presence of speckles within a bin. The geometric mean was most significantly deviated from the remaining methods regardless of the magnitude of chlorophyll-a concentration values. Its bias error tended to be large when the standard deviation within a bin increased with less uniformity. It was more biased when data uniformity became small. All the methods exhibited large errors as chlorophyll-a concentration values dominantly scatter in terms of time and space. This study emphasizes the importance of the speckle removal process and proper selection of average methods to reduce composite errors for diverse scientific applications of satellite-derived chlorophyll-a concentration data.

Well Loss in Fractured Rock Formation with Radial Flow during Pumping Test (양수시험시 방사상흐름을 보이는 균열암반 대수층에서의 우물손실)

  • 이철우;이대하;정지곤;김구영;김용제
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.17-23
    • /
    • 2002
  • Pumping tests were carried out from seven wells in fractured rocks. The time-drawdown data were obtained from pumping wells and corrected for the elapsed time of step drawdown test using Cooper-Jacob's method. A statistical method. the least square of error, was used to yield the coefficient of aquifer losses, the coefficient of well losses, and the power which indicates the severity of the turbulence. The values of the power range from 1.65 to 6.48. The well losses result mainly from turbulent flow caused by radial flow nearby pumping wells. The turbulent flow depends on Reynolds number. Since the hydraulic characteristics of fractured rocks control the fluid velocity, the value of the power is an important factor to understand the aquifer system of fractured rocks.

Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel (풍동장치를 이용한 열선풍소계의 보정 및 실태 평가)

  • Ha, Hyun-Chul;Kim, Tae-Hyeung;Kim, Eun-A;Kim, Jong-Chul;Oh, Jung-Ryng;Jung, Ho-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF