• 제목/요약/키워드: error in test

검색결과 3,702건 처리시간 0.045초

반구상의 나선형 볼바측정을 통한 수직형 머시닝 센터의 오차 해석 및 보정 (Error Analysis and Compensation for the Volumetric Errors of a Vertical Machining Center Using Hemispherical Helix Ball Bar Test)

  • 양승한;김기훈;박용국
    • 한국정밀공학회지
    • /
    • 제19권9호
    • /
    • pp.34-40
    • /
    • 2002
  • Machining accuracy is affected by quasi-static errors of machining center. Since machine errors have a direct influence upon both the surface finish and geometric shape of the finished workpiece, it is very important to measure the machine errors and to compensate these errors. The laser measurement method for identifying geometric errors of machine tool has the disadvantages such as high cost, long calibration time and usage of volumetric error synthesis model. Accordingly, this paper deals with analysis of the geometric errors of a machine tool using ball bar test without using complicated error synthesis model. Statistical analysis method was adopted in this paper for deriving geometric errors using hemispherical helix ball bar test. As a result of experiment, geometric errors of the vertical machining center are compensated by 88%.

GNSS Airborne Multipath Error Modeling Under UAV Platform and Operating Environment

  • Kim, Minchan;Kim, Kiwan;Lee, Dong-Kyeong;Lee, Jiyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2015
  • In the case of an unmanned aerial vehicle (UAV) equipped with a GNSS sensor, a boundary line where the vehicle can actually exist can be calculated using a navigation error model, and safe navigation (e.g., precise landing and collision prevention) can be supported based on this boundary line. Therefore, for the safe operation of UAV, a model for the position error of UAV needs to be established in advance. In this study, the multipath error of a GNSS sensor installed at UAV was modeled through a flight test, and this was analyzed and compared with the error model of an existing manned aircraft. The flight test was conducted based on a scenario in which UAV performs hovering at an altitude of 40 m, and it was found that the multipath error value was well bound by the error model of an existing manned aircraft. This result indicates that the error model of an existing manned aircraft can be used in operation environments similar to the scenario for the flight test. Also, in this study, a scenario for the operation of multiple UAVs was considered, and the correlation between the multipath errors of the UAVs was analyzed. The result of the analysis showed that the correlation between the multipath errors of the UAVs was not large, indicating that the multipath errors of the UAVs cannot be canceled out.

NC선반의 원 운동정도 측정장치의 개발 (Developement of Measuring Units of circular Motion Accuracy on NC Lathe)

  • 김영석;김재열
    • 한국공작기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.1-7
    • /
    • 2001
  • It is very important to test circular motion accuracy of NC machine tools as it affects all other machines machined by them in industries. In this paper, it has become possible to detect errors of linear displacement of radial directions for circle tar motion accuracy test using newly assembled magnetic type of linear scale so called Magnescale ball-bar system. It has also organized computer program systems using tick pulses come out from computer for getting error motion data at colt start time interval in circular motion test on NC lathe. Error data gotten from test is expressed to plots and analysed to numerics by various statistical treatments.

  • PDF

롤 편심제어를 위한 편심 측정장치 개발 (Development of Displacement Measuring Sensor for Roll Eccentricity Contro1 at Hot Strip Mill)

  • 전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.167-167
    • /
    • 2000
  • This study aims at the development of REC sensor causing the gauge error in the hot strip rolling process, and the improvement of the hydraulic AGC (Automatic Gauge Control) system. The gauge error outbreaks from the various reasons, however, mainly the roll eccentricity is considered to cause a such kind of error. In the study, the REC (Roll Eccentricity Control System) sensor is designed using sensor An On - line test of the system shows the comprehensive effects of controlling the gauge error of the hot strip. On - Line test shows the possibility of enhancing the accuracy for gauge.

  • PDF

$K^n$ 요인배치법에서 포화실험에 의한 요인효과의 검정 (Tests of Factor Effect Using Saturated Design in $K^n$ Factorial Design)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2008년도 춘계학술대회
    • /
    • pp.295-299
    • /
    • 2008
  • This paper discusses tests of factor effect or contrast by the use of saturated design $k^n$ factorial design. The nine nonparametric rank measures in normality test using normal probability pot are proposed. Length's PSE(Pseduo Standard Error) test [4] which relies on the concept of effect sparsity is also introduced and extended to the margin of error(ME) and Simultaneous margin of error(SME).

  • PDF

사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석 (Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use)

  • 김민준;조성철;정용훈;원정훈
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.

결측 데이터 보정법에 의한 의사 데이터로 조정된 예측 최적화 방법 (Predictive Optimization Adjusted With Pseudo Data From A Missing Data Imputation Technique)

  • 김정우
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.200-209
    • /
    • 2019
  • 미래 값을 예측할 때, 학습 오차(training error)를 최소화하여 추정된 모형은 보통 많은 테스트 오차(test error)를 야기할 수 있다. 이것은 추정 모델이 주어진 데이터 집합에만 집중하여 발생하는 모델 복잡성에 따른 과적합(overfitting) 문제이다. 일부 정규화 및 리샘플링 방법은 이 문제를 완화하여 테스트 오차를 줄이기 위해 도입되었지만, 이 방법들 또한 주어진 데이터 집합에서만 국한 되도록 설계되었다. 본 논문에서는 테스트 오차 최소화 문제를 학습 오차 최소화 문제로 변환하여 테스트 오차를 줄이기 위한 새로운 최적화 방법을 제안한다. 이 변환을 수행하기 위해 주어진 데이터 집합에 대해 의사(pseudo) 데이터라고 하는 새로운 데이터를 추가하였다. 그리고 적절한 의사 데이터를 만들기 위해 결측 데이터 보정법의 세 가지 유형을 사용하였다. 예측 모델로서 선형회귀모형, 자기회귀모형, ridge 회귀모형을 사용하고 이 모형들에 의사 데이터 방법을 적용하였다. 또한, 의사 데이터로 조정된 최적화 방법을 활용하여 환경 데이터 및 금융 데이터에 적용한 사례를 제시하였다. 결과적으로 이 논문에서 제시된 방법은 원래의 예측 모형보다 테스트 오차를 감소시키는 것으로 나타났다.

k-모집단 동질성검정에서 피어슨검정의 오차성분 분석에 관한 연구 (Error cause analysis of Pearson test statistics for k-population homogeneity test)

  • 허순영
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권4호
    • /
    • pp.815-824
    • /
    • 2013
  • 국가단위의 조사와 같은 대규모 표본조사에서는 표본의 대표성을 확보하기 위해 층화, 집락, 계통, 불균등확률추출 등을 종합적으로 사용하는 복합표본설계가 일반화되어 있다. 이러한 복합표본설계에 기초한 범주형 자료분석에서는 자료의 독립성과 다항분포를 가정하는 전통적인 피어슨검정이 왜곡된 검정결과를 가져올 수 있다. 본 연구는 복합표본설계에 의한 범주형조사자료의 k-모집단 동질성검정에서 설계기반 일치통계량인 Wald 검정통계량을 유도하고, 전통적인 피어슨검정통계량을 사용할 경우 발생할 수 있는 오차요인을 항목별로 분해하여, 분산의 편의에 의한 영향, 추정량의 편의에 의한 영향, 기타 분산의 편의와 추정량의 편의가 교락되어 미치는 영향으로 각각 분해하는 식을 도출하였다. 또한, 도출된 식의 각 항목이 피어슨 카이제곱검정통계량에 미치는 상대적 크기를 경험적으로 확인하기 위해 국민건강영양조사 제4기 2차년도 자료를 이용해 경험분석 하였다. 분석결과, 변수에 따른 차이는 있지만 대체로 분산의 편의가 미치는 영향이 추정량의 편의가 미치는 영향보다 크다는 것을 명확히 확인할 수 있었다.

방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구 (A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume))

  • 안양기;김지영;김금희;장희수;정정필;최종우
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.