• Title/Summary/Keyword: error in test

Search Result 3,717, Processing Time 0.04 seconds

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Impact of Awareness and Educational Experiences on Cardiopulmonary Resuscitation in the Ability to Execute of Cardiopulmonary Resuscitation among Korean Adults (한국 성인에서 심폐소생술에 대한 인지, 교육경험이 그 시행능력에 미치는 영향)

  • Lee, Jae-Kwang;Kim, Jeongwoo;Kim, Kunil;Kim, Keunhyung;Kim, Dongphil;Kim, Yuri;Moon, Seonggeun;Min, Byungju;Yu, Hwayoung;Lee, Chealim;Jeong, Wonyoung;Han, Changhun;Huh, Inho;Park, Jung Hee;Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.43 no.4
    • /
    • pp.234-249
    • /
    • 2018
  • This study was performed to identify the impact of awareness and educational experiences on cardiopulmonary resuscitation in the ability to execute of cardiopulmonary resuscitation among Korean adults. This study used original data of 2014 Community Health Data Survey. 228,712 participants in this survey were resident in South Korea who is aged 19 or older on July 2014. Participants in this survey were sampled an average of 900 residents(target error ${\pm}3percent$) per community health center of Korea. Data were analyzed by using R 3.1.3 employing chi-squared test, fisher's exact analysis, and logistic regression analysis. Ability to execute CPR was significantly higher in males(3.34 time), higher the education level (1.61 times), the white color occupation (1.14 times), the higher the income level (1.07 times), the higher the education level (0.91 times), non-hypertensive patients (1.12 times), non-diabetic patients (1.16 times), non-dyslipidemic patients (0.86 times), non-stroke patients (0.30 times), CPR education experience group (3.25 times), CPR experience group with manikin-based training (4.30 times), higher subjective health status (1.08 times, 1.16 times) respectively. This study identified that awareness, educational experience, and mannequin-based learning experience of CPR impacted on the ability to execute CPR. Responding to education-related factors could contribute to reducing the rate of out-of-hospital acute cardiac arrest by improving the ability to execute CPR of the general public.

A Study on the Dimensions, Surface Area and Volume of Grains (곡립(穀粒)의 치수, 표면적(表面積) 및 체적(體積)에 관(關)한 연구(硏究))

  • Park, Jong Min;Kim, Man Soo
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.1
    • /
    • pp.84-101
    • /
    • 1989
  • An accurate measurement of size, surface area and volume of agricultural products is essential in many engineering operations such as handling and sorting, and in heat transfer studies on heating and cooling processes. Little information is available on these properties due to their irregular shape, and moreover very little information on the rough rice, soybean, barley, and wheat has been published. Physical dimensions of grain, such as length, width, thickness, surface area, and volume vary according to the variety, environmental conditions, temperature, and moisture content. Especially, recent research has emphasized on the variation of these properties with the important factors such as moisture content. The objectives of this study were to determine physical dimensions such as length, width and thickness, surface area and volume of the rough rice, soybean, barley, and wheat as a function of moisture content, to investigate the effect of moisture content on the properties, and to develop exponential equations to predict the surface area and the volume of the grains as a function of physical dimensions. The varieties of the rough rice used in this study were Akibare, Milyang 15, Seomjin, Samkang, Chilseong, and Yongmun, as a soybean sample Jangyeobkong and Hwangkeumkong, as a barley sample Olbori and Salbori, and as a wheat sample Eunpa and Guru were selected, respectively. The physical properties of the grain samples were determined at four levels of moisture content and ten or fifteen replications were run at each moisture content level and each variety. The results of this study are summarized as follows; 1. In comparison of the surface area and the volume of the 0.0375m diameter-sphere measured in this study with the calculated values by the formula the percent error between them showed least values of 0.65% and 0.77% at the rotational degree interval of 15 degree respectively. 2. The statistical test(t-test) results of the physical properties between the types of rough rice, and between the varieties of soybean and wheat indicated that there were significant difference at the 5% level between them. 3. The physical dimensions varied linearly with the moisture content, and the ratios of length to thickness (L/T) and of width to thickness (W/T) in rough rice decreased with increase of moisture content, while increased in soybean, but uniform tendency of the ratios in barley and wheat was not shown. In all of the sample grains except Olbori, sphericity decreased with increase of moisture content. 4. Over the experimental moisture levels, the surface area and the volume were in the ranges of about $45{\sim}51{\times}10^{-6}m^2$, $25{\sim}30{\times}10^{-9}m^3$ for Japonica-type rough rice, about $42{\sim}47{\times}10^{-6}m^2$, $21{\sim}26{\times}10^{-9}m^3$ for Indica${\times}$Japonica type rough rice, about $188{\sim}200{\times}10^{-6}m^2$, $277{\sim}300{\times}10^{-9}m^3$ for Jangyeobkong, about $180{\sim}201{\times}10^{-6}m^2$, $190{\sim}253{\times}10^{-9}m^3$ for Hwangkeumkong, about $60{\sim}69{\times}10^{-6}m^2$, $36{\sim}45{\times}10^{-9}m^3$ for Covered barley, about $47{\sim}60{\times}10^{-6}m^2$, $22{\sim}28{\times}10^{-9}m^3$ for Naked barley, about $51{\sim}20{\times}10^{-6}m^2$, $23{\sim}31{\times}10^{-9}m^3$ for Eunpamill, and about $57{\sim}69{\times}10^{-6}m^2$, $27{\sim}34{\times}10^{-9}m^3$ for Gurumill, respectively. 5. The increasing rate of surface area and volume with increase of moisture content was higher in soybean than other sample grains, and that of Japonica-type was slightly higher than Indica${\times}$Japonica type in rough rice. 6. The regression equations of physical dimensions, surface area and volume were developed as a function of moisture content, the exponential equations of surface area and volume were also developed as a function of physical dimensions, and the regression equations of surface area were also developed as a function of volume in all grain samples.

  • PDF

Automatic Interpretation of Epileptogenic Zones in F-18-FDG Brain PET using Artificial Neural Network (인공신경회로망을 이용한 F-18-FDG 뇌 PET의 간질원인병소 자동해석)

  • 이재성;김석기;이명철;박광석;이동수
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.455-468
    • /
    • 1998
  • For the objective interpretation of cerebral metabolic patterns in epilepsy patients, we developed computer-aided classifier using artificial neural network. We studied interictal brain FDG PET scans of 257 epilepsy patients who were diagnosed as normal(n=64), L TLE (n=112), or R TLE (n=81) by visual interpretation. Automatically segmented volume of interest (VOI) was used to reliably extract the features representing patterns of cerebral metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Developing a Traffic Accident Prediction Model for Freeways (고속도로 본선에서의 교통사고 예측모형 개발)

  • Mun, Sung-Ra;Lee, Young-Ihn;Lee, Soo-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.2
    • /
    • pp.101-116
    • /
    • 2012
  • Accident prediction models have been utilized to predict accident possibilities in existing or projected freeways and to evaluate programs or policies for improving safety. In this study, a traffic accident prediction model for freeways was developed for the above purposes. When selecting variables for the model, the highest priority was on the ease of both collecting data and applying them into the model. The dependent variable was set as the number of total accidents and the number of accidents including casualties in the unit of IC(or JCT). As a result, two models were developed; the overall accident model and the casualty-related accident model. The error structure adjusted to each model was the negative binomial distribution and the Poisson distribution, respectively. Among the two models, a more appropriate model was selected by statistical estimation. Major nine national freeways were selected and five-year dada of 2003~2007 were utilized. Explanatory variables should take on either a predictable value such as traffic volumes or a fixed value with respect to geometric conditions. As a result of the Maximum Likelihood estimation, significant variables of the overall accident model were found to be the link length between ICs(or JCTs), the daily volumes(AADT), and the ratio of bus volume to the number of curved segments between ICs(or JCTs). For the casualty-related accident model, the link length between ICs(or JCTs), the daily volumes(AADT), and the ratio of bus volumes had a significant impact on the accident. The likelihood ratio test was conducted to verify the spatial and temporal transferability for estimated parameters of each model. It was found that the overall accident model could be transferred only to the road with four or more than six lanes. On the other hand, the casualty-related accident model was transferrable to every road and every time period. In conclusion, the model developed in this study was able to be extended to various applications to establish future plans and evaluate policies.

A Study on Significance Testing of Driver's Visual Behavior due to the VMS Message Display Forms on the Road (도로상 VMS 표출방식별 운전자 유의성 검증에 관한 연구)

  • Kum, Ki-Jung;Son, Young-Tae;Bae, Deok-Mo;Son, Seung-Neo
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.151-162
    • /
    • 2005
  • Variable Message Sign (VMS), which provides drivers with direct information about state of traffic congestion and for prevent an accident, is the most effective method among the methods of providing information in Advanced Transportation Management System. Currently establishment and the VMS which is operated foundation lets in Guidelines on the use of Variable message sign (a book of the VMS) of 1999 November the Ministry Construction & Transportation, these contents mean main viewpoint on physical part such as message special quality variable (font, character size and line space, word interval) and position mainly among standard about establishment in general. But, it is true that using without effect verification on the character of VMS display and that using mode of stationary-centered. In this paper, it executed significance test to effort verification on the character of VMS display for more practical and effective information transmission based on the driver viewpoint For the researches; develop 3D-Simulation, select characteristics of driver's visual cognition behavior (the conspicuity, the legibility and the comprehensibility), evaluation each issue (day or night, 80km/h or 100km/h). Especially, that used the Eye Marker Recorder to measure of reading-time (legibility) thus, confirmed objectivity and reduce an observational error. The results showed that the conspicuity is Flashing> Stationary>Scroll. The legibility is not deference that Flashing between stationary form. Also the comprehensibility result showed that Flashing> Stationary>Stroll form.

  • PDF

A Study of the Relation of Stress to Oral Health-Related of Life in Male High School Students of Chungnam (충남지역 일부 남자 고등학생들의 스트레스와 구강건강관련 삶의 질과의 관련성 연구)

  • Jung, Yu Yeon
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • This study is trying to grasp the stress of the male high school students and the correlation between the stress according to the oral health important cognitive and self-rated oral health status and number of brushing, emphasizing the need for the education of oral health important, providing the basic data in order to accomplish correctly until the enhance of oral health-related quality of the oral health correct behavior. From May to July 2013, a self administered survey was conducted by the selected by convenience sampling from subjects of two high school located in Chungcheongnam-do 1, 2 grade. The SPSS PASW Statistics 18.0 and Amos 5.0 program had been used for the statistical data analysis. The study results were as follow: 1) Among five areas of stress, the stress of school life was the highest as 2.11 points and the stress of home problem was the lowest as 1.51 points; 2) The significance analysis results between the five areas of stress according to the stress of latent variable and the oral health-related quality of life all showed the significant difference (p<0.001). 3) Oral health-related quality of life was higher as oral health important and self-rated oral health status positive. Furthermore oral health-related quality of life was higher as number of brushing increased; 4) Fit Measures test result of stress, academic level, and family economic level model all showed more than 0.9 in goodness of fit index (GFI), adjusted GFI, normed fit index and root mean square residual and root mean square error of approximation values is all estimated less than 0.1, so it showed good model. From this study, it can be concluded that there is the correlation between stress and oral health-related quality of life.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.