Dynamic properties of a building with viscous dampers in non-proportional arrangement

  • Suarez, Luis E.;Gaviria, Carlos A.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1241-1260
    • /
    • 2015
  • Any rational approach to define the configuration and size of viscous fluid dampers in a structure should be based on the dynamic properties of the system with the dampers. In this paper we propose an alternative representation of the complex eigenvalues of multi degree of freedom systems with dampers to calculate new equivalent natural frequencies. Analytical expressions for the dynamic properties of a two-story building model with a linear viscous damper in the first floor (i.e. with a non-proportional damping matrix) are derived. The formulas permit to obtain the equivalent damping ratios and equivalent natural frequencies for all the modes as a function of the mass, stiffness and damping coefficient for underdamped and overdamped systems. It is shown that the commonly used formula to define the equivalent natural frequency is not applicable for this type of system and for others where the damping matrix is not proportional to the mass matrix, stiffness matrix or both. Moreover, the new expressions for the equivalent natural frequencies expose a novel phenomenon; the use of viscous fluid dampers can modify the vibration frequencies of the structure. The significance of the new equivalent natural frequencies is expounded by means of a simulated free vibration test. The proposed approach may offer a new perspective to study the effect of viscous dampers on the dynamic properties of a structure.

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

Estimation of Nonlinear Site Effects of Soil Profiles in Korea (국내 지반에서의 비선형 부지효과 예측)

  • Lee, Hong-Sung;Yun, Se-Ung;Park, Du-Hee;Kim, In-Tai
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.3
    • /
    • pp.13-23
    • /
    • 2008
  • In a nonlinear site response analysis which is performed in time domain, small strain damping is modeled as viscous damping through use of various forms of Rayleigh damping formulations. Small strain damping of soil is known to be independent of the loading frequency, but the viscous damping is greatly influenced by the loading frequency. The type of Rayleigh damping formulation has a pronounced influence on the dependence. This paper performs a series of nonlinear analyses to evaluate the degree of influence of the viscous damping formulation on Korean soil profiles. Analyses highlight the strong influence of the viscous damping formulation for soil profiles exceeding 30 m in thickness, commonly used in simplified Rayleigh damping formulation overestimating energy dissipation at high frequencies due to artificially introduced damping. When using the full Rayleigh damping formulation and carefully selecting the optimum modes, the artificial damping is greatly reduced. Results are further compared to equivalent linear analyses. The equivalent linear analyses can overestimate the peak ground acceleration even for shallow profiles less than 20 m in thickness.

Design of supplemental viscous dampers in inelastic SDOF system based on improved capacity spectrum method

  • Li, Bo;Liang, Xing-Wen
    • Structural Engineering and Mechanics
    • /
    • v.27 no.5
    • /
    • pp.541-554
    • /
    • 2007
  • A simplified yet effective design procedure for viscous dampers was presented based on improved capacity spectrum method in the context of performance-based seismic design. The amount of added viscous damping required to meet a given performance objective was evaluated from the difference between the total demand for effective damping and inherent damping plus equivalent damping resulting from hysteretic deformation of system. Application of the method is illustrated by means of two examples, using Chinese design response spectrum and mean response spectrum. Nonlinear dynamic analysis results indicate that the maximum displacements of structures installed with supplemental dampers designed in accordance with the proposed method agree well with the given target displacements. The advantage of the presented procedure over the conventional iterative design method is also highlighted.

Energy-based numerical evaluation for seismic performance of a high-rise steel building

  • Zhang, H.D.;Wang, Y.F.
    • Steel and Composite Structures
    • /
    • v.13 no.6
    • /
    • pp.501-519
    • /
    • 2012
  • As an alternative to current conventional force-based assessment methods, the energy-based seismic performance of a code-designed 20-storey high-rise steel building is evaluated in this paper. Using 3D nonlinear dynamic time-history method with consideration of additional material damping effect, the influences of different restoring force models and P-${\Delta}/{\delta}$ effects on energy components are investigated. By combining equivalent viscous damping and hysteretic damping ratios of the structure subjected to strong ground motions, a new damping model, which is amplitude-dependent, is discussed in detail. According to the analytical results, all energy components are affected to various extents by P-${\Delta}/{\delta}$ effects and a difference of less than 10% is observed; the energy values of the structure without consideration of P-${\Delta}/{\delta}$ effects are larger, while the restoring force models have a minor effect on seismic input energy with a difference of less than 5%, but they have a certain effect on both viscous damping energy and hysteretic energy with a difference of about 5~15%. The paper shows that the use of the hysteretic energy at its ultimate state as a seismic design parameter has more advantages than seismic input energy since it presents a more stable value. The total damping ratio of a structure consists of viscous damping ratio and hysteretic damping ratio and it is found that the equivalent viscous damping ratio is a constant for the structure, while the equivalent hysteretic damping ratio approximately increases linearly with structural response in elasto-plastic stage.

An overview of the prediction methods for roll damping of ships

  • Falzarano, Jeffrey;Somayajula, Abhilash;Seah, Robert
    • Ocean Systems Engineering
    • /
    • v.5 no.2
    • /
    • pp.55-76
    • /
    • 2015
  • Of all the six degrees of freedom, the roll motion of a ship is the most poorly understood and displays complicated phenomena. Due to the low potential wave damping at the natural frequency, the effective analysis of ship roll dynamics comes down to the accurate estimation of the viscous roll damping. This paper provides overview of the importance of roll damping and an extensive literature review of the various viscous roll damping prediction methods applied by researchers over the years. The paper also discusses in detail the current state of the art estimation of viscous roll damping for ship shaped structures. A computer code is developed based on this method and its results are compared with experimental data to demonstrate the accuracy of the method. While some of the key references describing this method are not available in English, some others have been found to contain typographic errors. The objective of this paper is to provide a comprehensive summary of the state of the art method in one place for future reference.

The influences of equivalent viscous damping ratio determination on direct displacement-based design of un-bonded post-tensioned (UPT) concrete wall systems

  • Anqi, Gu;Shao-Dong, Shen
    • Smart Structures and Systems
    • /
    • v.30 no.6
    • /
    • pp.627-637
    • /
    • 2022
  • Recent years, direct displacement-based design (DDBD) procedure is proposed for the design of un-bonded posttensioned (UPT) concrete wall systems. In the DDBD procedure, the determination of the equivalent viscous damping (EVD) ratio is critical since it would influence the strength demand of the UPT wall systems. Nevertheless, the influence of EVD ratio determination of the UPT wall systems were not thoroughly evaluated. This study was aimed to investigate the influence of different EVD ratio determinations on the DDBD procedure of UPT wall systems. Case study structures with four, twelve and twenty storeys have been designed with DDBD procedure considering different EVD ratio determinations. Nonlinear time history analysis was performed to validate the design results of those UPT wall systems. And the simulation results showed that the global responses of the case study structures were influenced by the EVD ratio determination.

A Performance Analysis and Experiment of Viscous Torsional Vibration Damper for High Speed Engine Shaft System (고속엔진축계용 점성 비틀림진동감쇠기의 성능해석 및 실험)

  • Yang, B.S.;Jeong, T.Y.;Kim, K.D.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.98-105
    • /
    • 1997
  • In general, crankshafts which are used in internal combustion reciprocating engines are subjects to high torsional vibration. Therefore, a damper is often used to minimize the torsional vibration in reciprocating engines. In this paper, in order to investigate damping performance of viscous damper, the real effective viscosity and complex damping coefficient of silicone oil, and the effective inertia moment of inertia ring are calculated considering the relative motion between damper casing and inertia ring. Based on these results multi-cylinder shaft is modeled into equivalent 2-degree of freedom system and optimum condition is estimated by calculating the amplification factor of viscous damper. Also the test damper was manufactured according to the result of theoretical investigation, the performance and durability was ascertained through experimental examination.

  • PDF

Closed Form Formulas for Equivalent Damping Ratios of a Linear Structure Equipped with Damping Devices (제진장치가 설치된 구조물의 등가감쇠비)

  • Hwang, Jae-Seung;Lee, Sang-Hyun;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.370-377
    • /
    • 2002
  • Hwang et al (2001) proposed a new method for an evaluation of equivalent damping ratios of a linear structure with linear or nonlinear damping devices. This procedure has a disadvantage that it requires time history analysis for the whole system including damping devices, which may be troublesome for practical application. To tackle this problem closed form formulas for equivalent damping ratios are proposed in this study. It is assumed that the responses of MDOF system can be reproduced by an equivalent SDOF system which vibrates in a fundamental mode. The numerical analyses of a ten-story building equipped with linear viscous damper or active mass damper or friction damper show the effectiveness of equivalent SDOF model and closed form formulas.

  • PDF

Seismic Retrofit of Asymmetric.Elasto-Plastic Structure Using Viscous Dampers (점성감쇠기를 이용한 비대칭.비탄성구조물의 내진보강)

  • 김진구;방성혁
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.87-93
    • /
    • 2002
  • A procedure for figuring out proper amount of additional viscous damping required to keep the inelastic deformation of a plan-wise asymmetric structure within a given target performance point was developed. To this end the behavior of an asymmetric nonlinear structure after yielding is investigated. Then a formula for the required amount of equivalent damping was derived based on the ductility demand of the structure. The procedure was applied to a five-story asymmetric structure subjected to an earthquake load. According to the comparison with the results from the dynamic time-history analysis, the structure with viscous dampers installed in accordance with the proposed procedure showed satisfactory seismic performance in both the stiff and the flexible edges.