• 제목/요약/키워드: equivalent time

검색결과 2,088건 처리시간 0.028초

4포트 커넥터 시스템의 등가회로 변환에 관한 연구 (Equivalent Circuit Model for Four Port Connector System)

  • 심민규;김종민;나완수
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

Sky-bridge로 연결된 구조물의 지진해석을 위한 등가모델 (An Equivalent Model for Seismic Analysis of Structures Connected by a Sky-bridge)

  • 양아람;김현수;이동근;안상경;오정근;문영종
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.203-208
    • /
    • 2008
  • Recently, high-rise building structures connected by a sky-bridge are frequently constructed. To predict accurate dynamic responses of structures connected a sky-bridge, time history analysis is required. Repetitive analyses are required in the design process. If the entire structure model is employed in the repetitive time history analysis, it would take a lot of computational time and engineers' efforts. Therefore, an equivalent model for high-rise building structures connected by a sky-bridge was proposed in this study. The proposed model consists of cantilever having original structure's stiffnesses and masses. Based on the analytical results, it has been shown that the equivalent model can reduce the analysis time and provide similar seismic responses to the original model.

  • PDF

전력계통 과도현상 해석을 위한 상영역에서의 등가축약 기법 (A Phase-Domain Equivalent Representation for Electromagnetic Transients Studies)

  • 정병태;김성희;허성일;안복신;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.731-733
    • /
    • 1996
  • In this paper, a new time-domain reduction method for unbalanced 3 phase power systems will be represented. The impulse response of the system is used to identify a discrete-time equivalent filter model. The model is formulated directly in the phase domain. Each phase has a self-mode equivalent model and two mutual-mode equivalent models. The equivalent model is determined by the transfer function identification technique based on the Prony analysis. The model is implemented in EMTDC and tested with an unbalanced 3 phase network. The result of test showed that the equivalent model is accurate.

  • PDF

Kinetic Parameters 결정을 위한 Equivalent Point Method의 이용 (Application of the Equivalent Point Method for Estimation of Kinetic Parameters)

  • 임종환
    • 한국식품과학회지
    • /
    • 제22권5호
    • /
    • pp.582-589
    • /
    • 1990
  • 본 고에서는 Equivalent time과 Equivalent temperature를 활용하여 Kinetic parameters를 결정하는 새로운 방법을 제안하였다. 본 방법의 타당성을 두 가지의 kinetic data 즉, 계산치와 실험치를 이용하여 예시하였다. 계산치는 그 Kinetics가 잘 알려진 세 가지 화학반응에 대해 임의의 등온가열조건을 적용하여 계산하였고 실험치는 2% 설탕용액을 사용하여 0.0005N 염산용액을 사용하여 가수분해가 일어나는 정도를 효소반응을 이용하여 측정하였다. 본 방법에 의해 결정된 활성화 에너지와 Frequency factor는 각각 $104.74{\pm}1.87KJ/mol$$5.26{\times}10^{14)hr^{-1}$이었으며 이들 값은 보고된 결과와 잘 일치되었다.

  • PDF

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent)

  • 왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • 한국임상보건과학회지
    • /
    • 제8권1호
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

Determination of equivalent blasting load considering millisecond delay effect

  • Song, Zhan-Ping;Li, Shi-Hao;Wang, Jun-Bao;Sun, Zhi-Yuan;Liu, Jing;Chang, Yu-Zhen
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.745-754
    • /
    • 2018
  • In the analysis of the effects of rock tunnel blasting vibration on adjacent existing buildings, the model of simplified equivalent load produces higher calculation result of vibration, due to the lack of consideration of the millisecond delay effect. This paper, based on the static force equivalence principle of blasting load, proposes a new determination method of equivalent load of blasting vibration. The proposed method, based on the elastic-static force equivalence principle of stress wave, equals the blasting loads of several single blastholes in the same section of millisecond blasting to the triangle blasting load curve of the exploded equivalent elastic boundary surface. According to the attenuation law of stress wave, the attenuated equivalent triangle blasting load curve of the equivalent elastic boundary is applied on the tunnel excavation contour surface, obtaining the final applied equivalent load. Taking the millisecond delay time of different sections into account, the time-history curve of equivalent load of the whole section applied on the tunnel excavation contour surface can be obtained. Based on Sailing Tunnel with small spacing on Sanmenxia-Xichuan Expressway, an analysis on the blasting vibration response of the later and early stages of the tunnel construction is carried out through numerical simulation using the proposed equivalent load model considering millisecond delay effect and the simplified equivalent triangle load curve model respectively. The analysis of the numerical results comparing with the field monitoring ones shows that the calculation results obtained from the proposed equivalent load model are closer to the measured ones and more feasible.

병렬구조 시스템의 고장률, 유효(有效) 고장률과 대등(對等) 고장률의 비교분석 (A Comparative Analysis of Failure Rate, Effective Failure Rate and Equivalent Failure Rate of A System Composed of Identical Parallel Units)

  • 조경환
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권4호
    • /
    • pp.256-261
    • /
    • 2015
  • The aim of this paper is to present some issues to be discussed in relation to failure rate of a system that has identical parallel units. It is assumed that Time-to-Failure of each unit has the same exponential distribution and all units are repairable with a periodic maintenance of time interval T. Effective failure rate is widely recommended for nonrepairable systems as the reciprocal of MTTF but it should not be applied for repairable systems if delayed maintenance is used. And equivalent failure rate of an imaginary system is taken into consideration, the reliability value of which is the same as that of the redundant system when time interval T is given. With a numerical example, failure rate, effective failure rate, and equivalent failure rate of the redundant system are analyzed comparatively.

슬롯피치 경계 조건을 이용한 인버터 구동 유도 전동기의 회전자 등가회로 정수 추출 및 특성해석 (Analysis of Inverter-Fed Induction Motor Using F.E.M and Harmonic Equivalent Circuit)

  • 이건호;김병태;권병일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권7호
    • /
    • pp.331-338
    • /
    • 2002
  • An inverter-fed induction is driven by a harmonic voltage source so that it is necessary to be analysed by time-stepping F.E.M. But it takes so long time that disadvantageous to design. This paper presents a simple analysis method for inverter-fed induction motor using FEM and harmonic equivalent circuit. First, the rotor bar resistance and the leakage reactance are determinated by FEA for 1 slot region in rotor to consider the skin effect and the saturation. Secondly, the characteristic of the motor is analyzed by the harmonic equivalent circuits consisting of the obtained parameters from the FEA. This method is carried out to analyze an induction motor driven by the sinusoidal voltage and the inverter. The results are verified by comparing with those of the time-step F.E.A and the experiment.

유한요소법을 이용한 3상 유도전동기 등가회로에서의 파라미터 계산 (Estimation of Equivalent Circuit Parameters of Three-Phase Induction Motor Utilizing Finite Element Method)

  • 장전해;렌지얀;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.983-984
    • /
    • 2011
  • An effective estimation method of equivalent circuit parameters of three-phase induction motor by using FEM is presented in this paper. Arbitrary three torque-speed points at asynchronous speed on the torque-speed curve are required by using time-stepping FEM, then the equivalent circuit parameters of IM can be calculated rapidly with presented method. After obtaining the equivalent circuit parameters, the general analysis method based on equivalent circuit can be used to get entire torque-speed curve very quickly. Although the purely numerical method such as FEM also can estimate torque-speed curve directly and accurately, however, usually this process is time consuming.

  • PDF