• Title/Summary/Keyword: equivalent strength

Search Result 876, Processing Time 0.026 seconds

Estimation of the Compressive Strength of the Concrete incorporating Mineral Admixture based on the Equivalent Age Method (등가재령방법에 의한 혼화재 종류별 콘크리트의 압축강도 증진해석)

  • Han, Min-Cheol;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.71-77
    • /
    • 2007
  • This paper is to investigate the effect of the curing temperature on strength development of concrete incorporating cement kiln dust(CKD) and blast furnace slag (BS) quantitatively. Estimation of the compressive strength of the concrete was conducted using the equivalent age equation and the rate constant model proposed by Carino. Correction of Carino model was studied to secure the accuracy of strength development estimation by introducing correction factors regarding rate constant and age. An increasing curing temperature results in an increase in strength at early age, but with the elapse of age, strength development at high curing temperature decreases compared with that at low curing temperature. Especially, the use of BS has a remarkable strength development at early age and even at later age, high strength is maintained due to accelerated pozzolanic activity resulting from high temperature. Whereas, at low curing temperature, the use of BS leads to a decrease in compressive strength. Accordingly, much attention should be paid to prevent strength loss at low temperature. Based on the strength development estimation using equivalent age equation, good agreements between measured strength and calculated strength are obtained.

Prediction of Ultimate Strength of Concrete Deep Beams with an Opening Using Strut-and-Tie Model (스트럿-타이 모델에 의한 개구부를 갖는 깊은 보의 극한강도 예측)

  • 지호석;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.189-194
    • /
    • 2001
  • In this study, ultimate strength of concrete deep beams with an opening is predicted by using Strut-and-Tie Model with a new effective compressive strength. First crack occurs around an opening by stress concentration due to geometric discontinuity. This results in decreasing ultimate strength of deep beams with an opening compared with general deep beams. With fundamental notion that ultimate strength of deep beam with an opening decreases as a result of reduction in effective compressive strength of a concrete strut, an equivalent effective compressive strength formula is proposed in order to reflect ultimate strength reduction due to an opening located in a concrete strut. An equivalent effective compressive strength formula which can reflect opening size and position is added to a testified algorithm of predicting ultimate strength of concrete deep beams. Therefore, ultimate strength of concrete deep beam with an opening is predicted by using a simple and rational STM algorithm including an equivalent effective compressive strength formula, not by finite element analysis or a former complex Strut-and-Tie Model

  • PDF

An Experimental Study on the Liquefaction Resistance Strength Using Real Earthquake Loadings Considering Seismic Magnitude in Moderate Earthquake Region (실지진하중을 이용한 중진지역에서의 액상화 저항강도에 관한 실험적 연구)

  • 김수일;최재순;박성용;박근보;심재욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.569-576
    • /
    • 2003
  • Based on the equivalent uniform stress concept Presented by Seed and Idriss, sinusoidal cyclic loads which simplified earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. The liquefaction assessment method which was invented by using the equivalent uniform stress concept is suitable for the severe earthquake region such as Japan or USA, so the proper method to Korea is needed. In this study, estimation of the resistance to liquefaction was conducted by applying real earthquake loading to the cyclic triaxial test. From the test results, the characteristics of the fine sand under moderate earthquake were analyzed and compared with the results under strong earthquakes. Typically real earthquake loads used in this study are divided into two types - impact type and vibration type. Furthermore, results of the liquefaction resistance strength based on the equivalent uniform stress concept and tile concept using real earthquake loading were compared.

  • PDF

An Experimental Study on Post-Crack Equivalent Strength of Steel Fiber Reinforced Concrete (강섬유보강 콘크리트의 균열 후 등가인장강도에 관한 실험적 연구)

  • 박홍용;안영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.635-638
    • /
    • 2000
  • This experimental were carried out in order to investigate the equivalent strength of SFRC (Steel Fiber Reinforced Concrete). Tow hundred and tenh SFRC beeam (size: 150x150x550) were used in the tests the relationships between loading and mid-point deflections of the beams were observed four oint bending loading. From the test results, prediction formulas for the equivalent strength of SFRC beams are suggested.

  • PDF

Estimation of Compressive Strength of Concrete Incorporating Admixture (혼화재 치환 콘크리트의 압축강도 증진해석)

  • Joo Eun-Hee;Pei Chang-Chun;Han Min-Cheol;Sohn Myoung-Soo;Jeon Hyun-Gyu;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.75-78
    • /
    • 2005
  • This raper investigates the effect of curing temperature on strength development of concrete incorporating cement kiln dust(CKD) and blast furnace slag (BS) quantitatively. Estimation of compressive strength of concrete was conducted using equivalent age equation and rate constant model. An increasing curing temperature results in an increase in strength at early age, but with the elapse of age, strength development at high curing temperature decreases compared with that at low curing temperature. Especially, the use of 35 has a remarkable strength development at early age and even at later age, high strength is maintained due to accelerated pozzolanic activity resulting from high temperature. Whereas, at low curing temperature, the use of BS leads to a decrease in compressive strength. Accordingly, much attention should be paid to prevent strength loss at low temperature. Based on the strength development estimation using equivalent age equation, good agreements between measured strength and calculated strength are obtained.

  • PDF

An Experimental Study on the Relation of Compressive Strength and the Equivalent Age according to the Kind of Cement (시멘트종류에 따른 압축강도와 등가재령 관계에 관한 실험적 연구)

  • Na, Chul-Sung;Jang, Jong-Ho;Khil, Bae-Su;Kim, Jung-II;Nam, Jae-Hyun;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.13-16
    • /
    • 2003
  • There is no study that application of the maturity using H.B.C and H.S.C. Also activation energy has different values according to the cement, admixture and water-cement ratio. Therefore to make accurate explanation for the effect of temperature on concrete strength development properties, it is necessary that activation energy value according to the kind of cement is reviewed. This study compares and estimates equivalent age using activation energy value obtained by this experiment and Freiesleben activation energy value with compressive strength of concrete. As the result of this study, activation energy value obtained by this study has more accurate explanation of temperature's influence on concrete strength development than Freiesleben activation energy value.

  • PDF

An Experimental Study on the Relation of Compressive Strength and the Equivalent Age according to the Kind of Cement (시멘트종류에 따른 압축강도와 등가재령 관계에 관한 실험적 연구)

  • 나철성;장종호;길배수;김정일;남재현;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.13.1-16
    • /
    • 2003
  • There is no study that application of the maturity using H.S.C and H.S.C. Also activation energy has different values according to the cement, admixture and water-cement ratio. Therefore to make accurate explanation for the effect of temperature on concrete strength development properties, it is necessary that activation energy value according to the kind of cement is reviewed. This study compares and estimates equivalent age using activation energy value obtained by this experiment and Freiesleben activation energy value with compressive strength of concrete. As the result of this study, activation energy value obtained by this study has more accurate explanation of temperature's influence on concrete strength development than Freiesleben activation energy value.

  • PDF

An Experimental Study on the Prediction Model for the Compressive Strength of Concrete according to Replacement Ratio of Ground Granulated blast-furnace slag (고로슬래그 미분말의 치환율을 고려한 압축강도예측모델에 관한 실험적 연구)

  • Yang, Hyun-Min;Park, Won-Jun;Lee, Han-Seoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.89-90
    • /
    • 2013
  • This study is to predict the compressive strength for the concrete of ground granulated blast-furnace slag, and use Plowman's, Gompertz's model. The results are as follows; The prediction compressive strength were simiar using Rastrup's equivalent age model. but The prediction compressive strength using Freiesleben's equivalent age model weren't simiar in bfs replacement Ratio of 50%, because it is analyzed as the activation energy.

  • PDF

A Study on the Reinforced Method of Doubler Plate in Ship Hull Structure (선박 이중판의 보강법 연구)

  • HAM JUH-HYEOK
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.39-47
    • /
    • 2003
  • A study of the structural strength evaluation on the doubler plate, considering various load cases that were subjected to in-plane and out of plane combined load, has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate for various load cases, elasto-plastic large deflection analysis is introduced, including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed, based on the results. In order to compare the doubler structure with the original strength of main plate, without doubler, simple formulas for the evaluation of the equivalent flat plate thickness are derived for each load case, respectively, based on the additional series of analysis of flat plate structure. Using these derived equations, the thickness change of an equivalent flat plate is analyzed according to the variation of various design parameters of doubler platesome design guides are suggested in order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent flat plate formula and the developed buckling strength formulas are discovered, and these relations are formulated for the future development of simple strength evaluation formula of general doubler plate structure.

Strength Evaluation of a Doubler Plate of Ship Structure subjected to the In-plane Combined Load and Lateral Pressure Load (면내 조합하중과 횡압을 받는 선박 이중판의 강도 평가)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.37-48
    • /
    • 2003
  • A study for the structural strength evaluation of doubler plates subjected to the in-plane combined load and lateral pressure load has been performed through a systematic evaluation process. In order to properly estimate the static strength of doubler plate, elasto-plastic large deflection analysis is introduced including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed based on the analysis results. Also, in order to compare the doubler structure with the original strength of main plate without doubler, a simple formula for the evaluation of the equivalent flat plate thickness is derived based on the additional series analysis of fiat plate structure. Using this derived equation, the thickness change of a equivalent flat plate is analyzed according to the variation of various design parameters of doubler plate and some design guides are suggested In order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent plate thickness formula and the developed buckling strength formulas for intact plates by author et al. is discovered and these relations are formulated for the future development of simple strength evaluation formula of doubler plate structure.