• Title/Summary/Keyword: equivalent power

Search Result 1,752, Processing Time 0.027 seconds

Analysis on the Qualitative Performance of a Power Split/Circulation Transmission (동력분기/순환구조 동력전달계의 정성적 성능 해석)

  • Lim, W.S.;Lee, D.J.;Lee, J.M.;Park, Y.I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.212-223
    • /
    • 1995
  • To improve the efficiency of a power transmission system with slip elements, power split/circulation system is applied. The performance of a power split/circulation system varies widely by the change of the followings; the layout of system, the type and gear ratio of planetary gear, the performance of slip element, etc. Therefore, when one designs such a power transmission system or when one determines the economic/power mode of system, a certain performance prediction method is needed. In this study, the internal power flow pattern of a power split/circulation system is theoretically analyzed on several transmission systems. And an effective performance prediction method(so called performance locus diagram) is presented. By this method, the effects of design factors can be easily understood and the qualitative performances of system can be clearly evaluated.

  • PDF

A Study for an Analytic Conversion between Equivalent Lenses (등가렌즈의 해석적인 변환방법에 대한 연구)

  • Lee, Jong Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2012
  • An equivalent lens is a lens which has the same total power of refraction and the same paraxial imaging characteristics for the marginal rays as another lens, but has a different axial thickness. In this study, an analytic lens conversion from a thick lens to its equivalent lens is investigated, then it is shown that the equivalent lens is a solution of a quadratic equation. Every thick lens corresponds to one of two real roots of this quadratic equation. Therefore, except in the case of a unique solution, the equation has a conjugate solution, the other of the two roots. The conjugate solution has the same axial thickness, power, and paraxial imaging characteristics, but it has different shape and aberration characteristics. The characteristics of an equivalent lens and its conjugate solution are examined by using a sample lens.

Comparison of Seismic Responses of Seismically Isolated NPP Containment Structures using Equivalent Linear- and Nonlinear-Lead-Rubber Bearing Modeling (등가선형 및 비선형 납-고무받침 모델을 이용한 면진된 원전구조물의 지진응답의 비교)

  • Lee, Jin Hi;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.

Generalized Stability Criterion for Multi-module Distributed DC System

  • Liu, Fangcheng;Liu, Jinjun;Zhang, Haodong;Xue, Danhong
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.143-155
    • /
    • 2014
  • The stability issues of a multi-module distributed DC power system without current-sharing loop are analyzed in this study. The physical understanding of the terminal characteristics of each sub-module is focused on. All the modules are divided into two groups based on the different terminal property types, namely, impedance (Z) and admittance (Y) types. The equivalent circuits of each group are established to analyze the stability issues, and the mathematical equations of the equivalent circuits are derived. A generalized criterion for multi-module distributed systems is proposed based on the stability criterion in a cascade system. The proposed criterion is independent of the power flow direction.

Development of on-line Transient Security Assessment Algorithm (온라인 과도안전도 평가 알고리즘 개발)

  • Kim Y. H.;Cha S. T.;Kim T. K.;Kim H. K.;Jeon M. R.;Choo J. B;Nam H. K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.91-93
    • /
    • 2004
  • This paper is to develope the fast screening algorithm for on line transient security assessment. All generators are represented in a classical model and stability index is defined as a ratio between acceleration power and deceleration power Critical machines and remaining machines are identified based on stability index and aggregated into two equivalent machines. And finally equivalent machines are reduced into OMIB system then CCT is computed. The Proposed algorithm is applied to the KEPCO system and obtained the reasonable results compared with TSA Tool.

  • PDF

Bending Analysis and Flexural Rigidity of Rectangular Corrugated Plates (사각 주름판의 굽힘강성 및 굽힘해석)

  • Jung, Kang;Kim, Young-Wann
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.38-44
    • /
    • 2012
  • In this paper, the bending characteristics of the corrugated plates is analyzed. The trapezoidally, triangularlly and sinusoidally corrugated plates are considered. The corrugated plate is treated as an orthotropic plate that has different flexural properties in two perpendicular directions. The equivalent bending and twisting rigidities for the equivalent orthotropic plates are derived. The equivalent flexural rigidities are estimated under the following postulations: (1) The angle of continuously corrugated plate is not changed after the deformation. (2) When the pure bending moment is applied in corrugated direction of the plate, the its plane is in pure bending. Several numerical examples are analyzed with the proposed method and compared with published results.

A Study on Equivalent Model of EEFL Based on the Equivalent Resistance and Capacitance Variation (등가 저항과 등가 커패시터 변화에 바탕을 둔 외부전극 형광램프의 등가모델 연구)

  • Cho Kyu-Min;Oh Won-Sik;Moon Gun-Woo;Park Mun-Soo;Lee Sang-Gil
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.59-61
    • /
    • 2006
  • A circuit model simulating the electrical characteristics of EEFL(External Electrode Fluorescent Lamp) is proposed. The model is based on linear approximation that represents the equivalent resistance and capacitance as a function of power. Simulation waveforms and experimental results are presented to verify feasibility of the equivalent model.

  • PDF

Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies (전자기 과도현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가)

  • Wang, Yong-Pil;Jeong, Hyeong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.296-301
    • /
    • 2002
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent AC system Equivalent (FDACSE) using Z-domain rational Function Fitting is presented and demonstrated. The FDACSE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This 1 & 2 port FDACSE have been applied to the New Zealand South Island AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port FDACSE developed under different condition (linear load, fault and nonlinear loading). The study results have indicated the robustness and accuracy of 1 & 2 port FDACSE for electromagnetic transient studies.

Structural Analysis on the System of Differential Gear (차동 기어 장치에 관한 구조 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.279-284
    • /
    • 2009
  • This study investigates the stress at gear by modelling differential gear and using FEM. When gear is driven under power, high equivalent stress of 1596.2MPa is occurred at the stationary shaft. Maximum equivalent stress of 1596.2MPa is also occurred at the bottom and root of tooth and its fatigue life becomes 12.4 as the shortest cycle. As much as it becomes away from the center of gear, the maximum deformation becomes occurred. As exact power is delivered with the precise design of gear, the loss of power energy can be decreased.

  • PDF

Modeling and Analysis of Active-Clamp, Full-Bridge Boost Converter (능동 클램프 풀브릿지 부스트 컨버터에 대한 모델링 및 분석)

  • Kim Marn-Go
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.610-614
    • /
    • 2004
  • Recently, an active-clamp, full-bridge boost converter has been actively studied for high-power applications such as power factor correction and battery discharger. However, DC and AC modeling for this converter has not conquered. In this paper, a DC and small-signal AC modeling for the active-clamp, full-bridge boost converter is described. Based on the operation principle, the ac part of the converter can be replaced by a do counterpart. Then, a conceptual equivalent circuit is derived by rearranging the switches. The equivalent circuit for this converter consists of CCM (Continuous conduction mode) boost and DCM (Discontinuous conduction mode) buck converter. The analyses for the equivalent CCM boost and DCM buck converter are done using the model of PWM switch. The theoretical modeling results are confirmed through experiment or SIMPLIS simulation.

  • PDF