• Title/Summary/Keyword: equivalent NaCl concentration

Search Result 28, Processing Time 0.033 seconds

Relationship Between the Groundwater Resistivity and NaCl Equivalent Salinity in Western and Southern Coastal Areas, Korea (국내 서.남해 해안지역 지하수의 전기비저항과 등가 NaCl 염분도와의 관계)

  • Hwang, Se-Ho;Park, Kwon-Gyu;Shin, Je-Hyun;Lee, Sang-Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.361-368
    • /
    • 2007
  • In this paper, we suggested the relationship between resistivity of coastal groundwater and NaCl equivalent salinity for the quantitative interpretation the results of surface/borehole resistivity and electromagnetic data. 38 groundwater samples having electrical conductivity higher than about 1,000 ${\mu}S/cm$ were analyzed to derive the empirical relationship between groundwater resistivity and NaCl equivalent salinity. We used Schlumberger chart GEN-8 to convert ion concentration from hydrochemical analysis to the equivalent NaCl salinity, and the portable meter to measure the in situ electrical conductivity of groundwater samples. From the hydrochemical analysis, relationship between the groundwater resistivity $(R_w)$ and equivalent NaCl salinity (Eq_NaCl) is expressed as Eq_NaCl=$5935.3551{\times}R_w^{-1.0993}$, and relationship between the groundwater electrical conductivity (EC) and total dissolved solids (TDS) is expressed as TDS=0.721*EC. We believe these relationships are very useful to assess the seawater intrusion in western and southern coastal area.

Assessment of seawater intrusion using geophysical well logging and electrical soundings in a coastal aquifer, Youngkwang-gun, Korea

  • Hwang Seho;Shin Jehyun;Park Inhwa;Lee Sangkyu
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.99-104
    • /
    • 2004
  • A combination of drilling, geophysical well logging, and electrical soundings was performed to evaluate seawater intrusion in Baeksu-eup, Youngkwang-gun, Korea. The survey area extends for over 24 $km^2$. To delineate the extent of seawater intrusion, 60 vertical electrical soundings (VES) have been carried out. Twelve wells were also drilled for the collection of hydrogeological, geochemical, and geophysical well logging data, to delineate the degree and vertical extent of seawater intrusion. To map the spatial distribution of seawater in this coastal aquifer, geophysical data and hydrogeochemical results were used, and the relation between the resistivity of groundwater and equivalent NaCl concentration was found. Layer parameters derived from VES data, various in-situ physical properties from geophysical well logging, and the estimated equivalent NaCl concentration were very useful for quantitative evaluation of seawater intrusion. Our approach for evaluating seawater intrusion can be considered a valuable attempt at enhancing the use of geophysical data.

지표 물리탐사법을 이용한 염/담수 영역의 고분해능 영상화

  • 박권규;신제현;박윤성;황세호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.446-449
    • /
    • 2004
  • High resolution geophysical imaging to delineate costal aquifer and seawater- freshwater interface has been applied in Baesu-eup, Yeonggwang-gun, Jeolla province Electrical resistivity information from vertical electrical sounding and 2-D electrical resistivity survey is key parameter to map equivalent Nacl concentration map over the survey area. Seismic velocity from refraction tomographic survey, on the other hand, gives more reliable information on the subsurface stratagraphy than electrical resistivity methods which frequently suffer from low resolution due to masking effect. We imaged high-resolution 3-D structure of costal aquifer by correlating the electrical resistivity with seismic velocity, and mapped equivalent NaCl concentration map using resistivity and hydro-geological information from well logging.

  • PDF

The Effects of Cement Alkalinity upon the Pore Water Alkalinity and the Chloride Threshold Level of Reinforcing Steel in Concrete

  • Nam Jingak;Hartt William H.;Kim Kijoon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.549-555
    • /
    • 2004
  • Cement of three alkalinities (equivalent alkalinities of 0.36,0.52 and 0.97) was employed in fabricating a set of classical G109 type specimens. To-date, these have been subjected to a one week wet-one week dry cyclic pending using 15 w/o NaCl solution. At the end of the dry period, potential and macro-cell current were measured to indicate whether the top reinforcing steel was in the passive or active state. Once this bar became active, the specimen was autopsied and the extent of corrosion was documented. Subsequent to visual inspection, concrete powder samples were collected from the upper region of the top rebar trace; and at a certain times concrete cores were taken from non-reinforced specimens. Using these, determinations were made of (1) critical chloride concentration for corrosion initiation ($Cl_{th}^-$), (2) effective chloride diffusion coefficient ($D_e$), and (3) pore water alkalinity ($[OH^-]$). The pore water alkalinity was strongly related to the alkali content of cement that was used in the mix. The chloride concentration, ($Cl^-$), was greater at active than at passive sites, presumably as a consequence of electro migration and accumulation of these species at active site subsequent to corrosion initiation. Accordingly, ($Cl^-$) at passive sites was considered indicative of the threshold concentration fur corrosion initiation. The $Cl_{th}^-$ was increased with increasing Time-to-corrosion ($T_i$). Consequently, the HA(High Alkalinity) specimens exhibited the highest $Cl_{th}^-$ and the NA(Normal Alkalinity) was the least. This range exceeds what has previously been reported in North America. In addition, the effective diffusion coefficient, $D_e$, was about 40 percent lower for concrete prepared with the HA cement compared to the NA and LA(Low Alkalinity) ones.

Ionic composition of aerosol particles under urban atmospheres of Seoul, Korea (서울시 대기중 입자상 오염물질의 조성에 관한 연구)

  • 한진석;김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.389-398
    • /
    • 1996
  • In order to understand the relative importance of various pathways leading to the production and transformation of aerosols under different atmospheric conditions, the behavior of atmospheric aerosols have been investigated using a high volume tape sample in Seoul for a week period during August 1990. The concentrations of anion $(SO^{2-}_4, NO^-_3, CI^-)$ and cation $(Ca^{2+}, Na^+, NH^+_4)$ species of aerosol samples were analyzed to identify the ionic composition of aerosols and to estimate their relative contributions to aerosol formation. The concentrations of aerosol species were calculated by a multiple regression model. The results of our calculations indicate the existence of various chemical species such as $(NH_4)_2SO_4, Na_2SO_4, CaSO_4, NH_4NO_3, NaNO_3, Ca(NO_3)_2, NH_4Cl$, and NaCl salts. According to our calculations, the most dominant species of aerosol was $(NH_4)_2SO_4$ with the mean concentration of 23.3 $/mu g/m^3$ (66.9%). The proportion of different componts with aerosol (e.g., $NH_4NO_3$ and $NH_4Cl$) was strongly affected by temperature, relative humidity, and partial presure of gases.

  • PDF

Interpretation of Chemistry Analytical Data in Precipitation (강수중 화학성분 분석자료의 해석)

  • 강공언;전종남;김희강
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.62-68
    • /
    • 1996
  • Precipitation samples were collected by the wet-only event sampling method at Seoul from September 1991 to April 1995. Concentrations of samples for the ion components($NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, F^-, Na^+, K^+, Ca^{2+}, Mg^{2+}$ and $NH_4^+$) were measured in addition to pH and electric conductivity. During the sampling period, 182 samples were collected, but only 163 samples were identified as valid. The pH, calculated from the volume-weighted $H^+$ concentration, was found to be 4.7, indicating a relatively intensive acidity compared with data from other regions of the world, where acid deposition was known to be a problem. Above all, the concentration of non-seasalt sulfate was $84 \mu eq/L$, which was the highest compared to that measured in other regions of the world. The major acidifying ions in the precipitation at Seoul were identified as sulfate and nitrate except for chloride, because the Cl/Na ratio in the precipitation was close to the ratio in seawater. If all of the non-seasalt sulfate and nitrate existed in the form of sulfuric and nitric acids, respectively, the average pH in the precipitation was calculated as 3.7, lower than the measured value. Consequently, the difference between the calculated and measured pH suggest that the acidity of precipitation was neutralized by alkaline species, not due to the low contribution of an anthropogenic air pollutants to the precipitation. The equivalent concentration ratio of sulfate to nitrate was 3.5, which indicated that the contributions of sulfuric and nitric acids to the precipitation acidity were 78% and 22%, respectively.

  • PDF

Synthesis of Dawsonite (Basic Sodium Aluminum Carbonate) from Colloidal Earth (Aoolphane) by Treatment with Acid and Alkali (膠質土酸, Alkali 處理에 의한 Dawsonite의 合成에 관한 硏究)

  • Kwon Sang Wook
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.157-164
    • /
    • 1969
  • Aoolphane was treated with 30% Hydrochloric acid at $18^{\circ}C$ for two hows with stirring in order to obtain the insoluble form of SiO2 gel and to extract quantitatively both $Al_2O_3$as and $Fe_2O_3AlCl_3{\cdot}6H_2O Fe$ and $Cl_3{\cdot}6H_2O$ forms, respectively, at the same time. $SiO_2$ gel was filtered and to the filterate Ammonia was added to precipitate $Al(OH)_3[Fe(OH)_3 Contaminated ]$ The precipitate was separated by filteration and the filterate was recovered as the form of $NH_4Cl$. The precipitate was treated with 200g (NaOH)/l Concentration of NaOH a little excessively to the equivalent at $65~70^{\circ}C$ as $Fe(OH)_3$ formed was insoluble, it was filtered of and to the filterate containing $NaAl(OH)_4(OH_2)_2$Carbon dioxide gas was bubbled at $50^{\circ}C~90^{\circ}C$ to obtain the precipitate with excellent filterability and crystallinity. The product was certified to be Dawsonite $(NaAl(OH)_2CO_3)$ by X-Ray diffraction analysis at below $40^{\circ}C$, when $CO_2$ gas was bubbled into the relatively lower concentration of $NaAl(OH)_4(OH_2)_2$ solution, the precipitate of very fine particles was formed, which was hard to filter and with the Composition of $\alpha-Al_2O_3-H_2O$ (Boehmite).

  • PDF

A Study on the Optimization of Physical and Chemical Parameters for the Precipitate of Sodium Alkylsulfate with Cetylpyridinium Chloride

  • Oh, Sun-Wha;Moon, Sung-Doo;Lee, Don-Keun;Lee, Dong-Jae;Kang, Young-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.280-284
    • /
    • 2004
  • The optimum conditions for the most effective precipitate of surfactant complex of sodium alkylsulfate with cetylpyridinium chloride were studied in the aqueous solution. The parameters such as the alkyl chain length of anionic surfactants, molar ratio of two surfactants, temperature and the concentration of added NaCl in the aqueous solution were correlatively studied for the productivity of the precipitate formation. By the productivity, the optimum conditions to produce complex of anionic surfactant with cationic surfactant were the longer alkyl chain, equivalent molar ratio between anionic and cationic surfactants, 0 $^{\circ}C$ and 1.5 M NaCl.

Rapid estimation of salinity in seawater intrusion zones and correlation analysis between resistivity and salinity (해수침투 지역의 염분농도 분포 파악 및 전기비저항의 상관성분석 사례)

  • Jung, Lae-Chul;Kim, Jung-Ho;Kim, Ki-Seog;Kim, Jong-Hoon;Ahn, Hee-Yoon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.307-312
    • /
    • 2007
  • Seawater intrusion in estuarine regions is an important issue in protecting groundwater against salinity increase as well as in protecting construction materials against corrosion. For example, drain water ejected during accelerated consolidation for the improvement of soft ground can cause damages to farm land because the drain water from seawater intrusion zones contains salinity. In this study, we have employed correlation analysis between resistivity value and salinity of in situ pore water. The correlation analysis indicates that resistivity and salinity are in exponential relationship with good correlation. Therefore we suggest that rapid estimation of spatial distribution of NaCl is possible using resistivity data.

  • PDF

Characterization of Chemical Properties of Precipitation at Busan, Korea, 2009 (2009년 부산지역 강수의 화학적 특성)

  • Jung, Woon-Seon;Park, Sung-Hwa;Kang, Deok-Du;Lee, Dong-In;Kim, Dongchul
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.69-79
    • /
    • 2014
  • The seasonal variation of pH and ion components in precipitation were investigated from January to December 2009 at Busan, Korea. The precipitation was acidic with a volume-weighted mean pH concentration of 5.32, which ranged from 3.79 to 8.66. The volume-weighted mean conductivity showed 86.77 ${\mu}S/cm$ and indicated higher concentration about 96.69 ${\mu}S/cm$ in summer. The volume-weighted mean equivalent concentration of components followed the order: $K^+$ > $Ca^{2+}$ > $nss-Ca^{2+}$ > $NH_4^+$ > $Mg^{2+}$ > $Na^+$ > $Li^+$ in cations and $Cl^-$ > $SO_4^{2-}$ > $nss-SO_4^{2-}$ > $NO_3^-$ > $NO^{2-}$ > $F^-$ > $Br^-$ in anions. Particularly, concentration of $K^+$ and $Cl^-$ showed 56 and 78 % in cations and anions. The higher concentration in $K^+$, $Na^+$, $Mg^{2+}$ and $Cl^-$ were shown in Busan city as compared to the other cities. The neutralization factors have been found to have higher value for potassium ion in winter compared with different seasons, indicating significant neutralization of acidic components over the region by potassium. Therefore, the precipitation characteristics at Busan had both continental and coastal as consequence of pH, conductivity and ionic analyses.