• Title/Summary/Keyword: equipment-based facility

Search Result 235, Processing Time 0.023 seconds

3-D Graphical Model-Based Design and Control of Automated Equipment (3차원 그래픽 모델에 근거한 자동화 장비의 설계 및 조종)

  • Seo Jongwon;Haas Carl
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.188-191
    • /
    • 2002
  • This paper concerns 3-D graphical modeling and simulation techniques for design and control of automated equipment for construction and facility maintenance. A case study on the use of 3-D graphics techniques for developing a power plant maintenance robot is presented. By simulating equipment operation within the 3-D geometry models of the work environment the environment design was improved. The 3-D graphical models of the equipment and the work environment were further utilized for the control of the robot from a remote distance. By presenting the real-time updated equipment configuration and the work environment to the operator, the graphical model-based equipment control system helped the operator overcome the problems associated with spatial perception. The collision between the robot and the plant structures was also avoided based the real-time analysis of the dynamically updated graphical models.

  • PDF

HOT CELL RENOVATION IN THE SPENT FUEL CONDITIONING PROCESS FACILITY AT THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE

  • YU, SEUNG NAM;LEE, JONG KWANG;PARK, BYUNG SUK;CHO, ILJE;KIM, KIHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.776-790
    • /
    • 2015
  • Background: The advanced spent fuel conditioning process facility (ACPF) of the irradiated materials examination facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI) has been renovated to implement a lab scale electrolytic reduction process for pyroprocessing. The interior and exterior structures of the ACPF hot cell have been modified under the current renovation project for the experimentation of the electrolytic reduction process using spent nuclear fuel. The most important aspect of this renovation was the installation of the argon compartment within the hot cell. Method: For the design and system implementation of the argon compartment system, a full-scale mock-up test and a three-dimensional (3D) simulation test were conducted in advance. The remodeling and repairing of the process cell (M8a), the maintenance cell (M8b), the isolation room, and their utilities were also planned through this simulation to accommodate the designed argon compartment system. Results and conclusion: Based on the considered refurbishment workflow, previous equipment in the M8 cell, including vessels and pipes, were removed and disposed of successfully after a zoning smear survey and decontamination, and new equipment with advanced functions and specifications were installed in the hot cell. Finally, the operating area and isolation room were also refurbished to meet the requirements of the improved hot cell facility.

A Study on Factory Monitoring System based on Manufacturing Facility Condition Diagnosis Algorithm (제조설비 상태 진단 알고리즘 기반의 공장 모니터링 시스템에 대한 연구)

  • Song, Enjoo;Song, Kyogin;Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.261-269
    • /
    • 2020
  • This paper introduces a facility simulation system for efficient error detection of smart factories. The facility simulation system, which can infer and solve errors autonomously when analyzing the relationship between plant facilities, is one of the important technologies for constructing a smart factory with high productivity. In order to implement this autonomic control system, it is necessary to be able to identify the status of facilities and analyze the relationship between facilities through the data of factory facilities. Therefore, in this paper, we design and develop a simulation program that can detect the equipment that causes the process error when an error occurs based on the process scenario using the defined equipment status. The simulation shows that the error inference process based on the process map and facility status is more efficient than the general error inference process. This simulation program provides an intuitive view of the reasoning and resolution of facility failures.

Usage Status Survey on Some Essential Facilities, Equipment and Documentary Records for HACCP Implementation in Contract Foodservices (HACCP 적용에 필요한 시설 . 설비 . 문서의 위탁급식소 구비 실태에 관한 조사)

  • Moon, Hye-Kyung;Ryu, Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.7
    • /
    • pp.1162-1168
    • /
    • 2004
  • In this study, based on SSOP (Sanitation Standard Operating Procedure) for HACCP in Food Sanitation Act, essential facility, equipment and documentary records for HACCP implementation were identified. Usage and adoption of these devices at Korea Food & Drug Administration appointed HACCP foodservices ("Appointed"), voluntary HACCP applying foodservices ("Voluntary applying") and HACCP non-applying foodservices ("Non-applying") have been compared. Total 46 contract foodservices were surveyed: 13 "Appointed" (65% of nation-wide all appointed food services in February, 2002),17 "Voluntary applying" and 16 "Non-applying". For usage and adoption of facility and equipment, 18 out of total 27 surveying items showed significant differences at the three foodservice groups (p<0.01 or p<0.05). Specifically, following items showed lower usage than 70% in the "Appointed": ′A trench including grease trap′, ′3-compartment sink with hot water′. Regarding CCP monitoring tool installation, 8 out of total 9 items showed significant differences among the groups (p<0.01 or p<0.05). For the usage of 10 documentary recording items for HACCP application log, 7 items showed significant differences among the groups (p<0.01 or p<0.05). Resultantly, most of those essential facilities, equipment and documentary records ;were used only in the "Appointed". The limited usages of those were showed for the "Voluntary applying" where the dietitian answered they applied HACCP voluntarily. The "Non-applying" didn′t have many surveyed items.

An intelligent consultant for material handling euqipment selection and evaluation

  • Park, Yang-Byung;Cha, Kyung-Cheon
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.79-90
    • /
    • 1995
  • The material handling equipment selection, that is a key task in the material handling system design, is a complex, difficult task, and requires a massive technical knowledge and systematic analysis. It is invaluable to justify the selected equipment model by the performance evaluation before its actual implementation. This paper presents an intelligent knowledge-based expert system called "IMESE" created by authors, for the selection and evaluation of material handling equipment model suitable for movement and storage of materials in a manufacturing facility. The IMESE is consisted of four modules: a knowledge base to select an appropriate equipment type, a multiple criteria decision making procedure to choose the most favorable commercial model of the selected equipment type, a database to store the list of commercial models of equipment types with their specifications, and simulators to evaluate the performance of the equipment model. The whole process of IMESE is executed under VP-Expert expert system environment.vironment.

  • PDF

Accuracy Improvement of Surveying & Mapping for Seabed Facilities (해저시설물 조사성과의 정확도 제고)

  • Kim, June-Sik;Choi, Yun-Soo;Park, Sun-Mi;Kang, Moon-Kwon
    • Spatial Information Research
    • /
    • v.17 no.1
    • /
    • pp.103-115
    • /
    • 2009
  • Recently, the seabed facility is gradually being increased based on the development of harbor and the coastal area. However, the comparison between the survey data with the chart still shows the significant differences leading to various disasters over sea accident. Therefore, in this study, the investigation on the seabed facility were performed in 5 areas through an accuracy analysis using an up-to-date surveying equipment(MBES, SSS and SBP). Based on the study more systematic management on the seabed facility, more accurate method on the surveying, and some considerations on the related policies are suggested. Through the study, we obtained more accurate measurement on depth and seabed piping forms in Jakdo and Pyong-tack, on sunken ship in a Mok-po, on seabed crater in Je-ju. In addition, it was possible to present the method for the construction of information infra and a connection with the seabed facility. The criteria on the equipment's specification, surveying method and procedures are set by the experiments and the investigation and surveying accuracy on the seabed facilities are also suggested.

  • PDF

Proposal of Localization Policy Based on the Status of Chinese's Research Facilities and Equipment Construction in Korean Basic and Analytical Science Field (국내 기초·분석과학 분야 내 중국산 연구시설·장비 구축 현황에 따른 국산화 정책 제언)

  • Kim, Chang-Yong;Chung, Taewon;Kong, Jaehyun;Park, Chan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.460-471
    • /
    • 2019
  • The aim of this study was to examine the scale and market share of Chinese's research facility & equipment in the domestic research equipment market of basic and analytical science field for analyzing the difference of the number and amount of construction by year of acquisition, national research facility equipment standard classification code, and type of institution based on the information of the research equipment invested by the Korean government for the past 14 years. In addition, we analyzed the correlation among the year of acquisition, equipment standard classification code, and type of institution variables. As of January 1 2019, from 2005 to 2018, 50 Chinese's research facilities & equipments (main equipment with a construction cost of 30 million won or more) built in the basic and analytical science fields were selected for this study and their number of construction, amount of construction, year of acquisition, type of institution, and standard classification code were analyzed. Differences of the number and amount of construction with-in and by year of acquisition, standard classification code, and type of institution were tested using a single sample Chi-square test, Mann-Whitney U test, and Kruskal-wallis test. The correlation among the three variables was analyzed by using the Chi-square test of cross-tabulation analysis. And there was a statistically significant correlation among the year of acquisition, standard classification code, and type of institution (p<.05). Compared to the 2000s, in the 2010s, high-priced Optical Electronics/Video Equipment was installed at private universities, private enterprises, and government-affiliated research institute. Therefore, the domestic construction status of Chinese's research facility & equipment in the basic science and analytical science field is less than that of the domestic ones, but the number and the amount of construction are increasing statistically. So it is necessary for the government to be able to recognize the possibility that the Chinese's research facility and equipment can encroach on the domestic research industry market and to prepare related provision.

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant (푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용)

  • Choi, Gyeong-Gy;Chang, Hye-Ja
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.

Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis (AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구)

  • Lee, Jeong Han;Kim, Yong Gon;Lee, Jae Won;Kim, Jong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.