Review on the Relationship of Dissolved Gas Analysis and Internal Inspection of Transformer (변압기 절연재료 분석과 내부점검 결과와의 상관성 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Jung, Nyun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1869-1873
    • /
    • 2010
  • For reliable operation of oil-filled electrical equipment, monitoring and maintenance of insulating oil is essential. Dissolved gas analysis(DGA) is widely used for monitoring faults in high voltage electrical equipment in service. Therefore, oil analysis should be monitored regularly during its service life. KEPCO has investigated thousands of dissolved gas analysis data since 1985, and conducted studies on the relationship of gas in oil analysis and internal inspection results of transformer. As the results, KEPCO revised criteria for transformer diagnosis and has applied it since 2008. Almost of 100 cases of internal inspection results since 2001 have been investigated. This paper presents the correlation of the fault-identifying gases with faults found in actual transformers and how should we approach to internal inspection of transformer by dissolved gas analysis.

Extraction of Canine Cataract Object for Developing Handy Pre-diagnostic Tool with Fuzzy Stretching and ART2 Learning

  • Kim, Kwang Baek
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • Canine cataract is developed with aging and can cause the blindness or surgical treatment if not treated timely. The first observation must be made by pet owners but they do not have proper equipment and knowledge to see the abnormalities. In this paper, we propose an intelligent image processing method to extract canine cataract suspicious object from non-professional equipment such as ordinary digital camera and cellular phone photographs so that even casual owners of pet dog can make a pre-diagnosis of such a surgery-needed disease as soon as possible. The experiment shows that the proposed method is successful in most cases except the dog has similar colored hair to the color of cataract.

A Study on the Microbial Contaminant Transport and Control Method According to Government Building Bio- Attack (청사 건물의 Bio-Attack에 따른 미생물 오염원 확산 및 제어방안에 관한 연구)

  • Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.252-259
    • /
    • 2008
  • The purpose of this study is to estimate the movement of microbial contaminant caused by bio-attack using bio-agent such as bacillus anthracis for preventing contaminant diffusion. multizone simulation was carried out in the case of three types of bio-attack scenario in the government building. Simulation results show that severe contaminant diffusion is brought about in all cases of bio-attack scenario in one hour, though pollution boundaries have different mode according to bio-attack scenarios. Simulation results also show that immune building technology such as filter and UVGI technology gives us powerful alternatives to meet the emergent situation caused by unexpected bio-attack.

OPTIMAL DESIGN ALGORITHM OF THE FOUNDATION OF TOWER CRANES

  • Kim, Sun-Kuk;Kim, Jang-Young;Ryu, Sang-Yeon
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1047-1052
    • /
    • 2009
  • As buildings nowadays become taller in height and larger in size the safety review of lifting plan takes larger portion in construction project management. However, the cost and safety in lifting plan have a contradictory effect on each other. Therefore, an optimization algorithm needs devising as a solution of the contradictory problem. In many cases at construction sites, selections and stability review of tower cranes are assigned to equipment suppliers or field managers, which cause the problems in safety and cost of the projects. To improve the part of the current situation, a study on the optimization algorithm for designing the foundation of tower cranes is conducted in this study, which can be utilized by equipment suppliers or field managers to check the stability of tower cranes easily and promptly without substantial knowledge.

  • PDF

A Study on Gas-Liquid Reaction Intensification by Using Rotating Flow (회전유동을 이용한 기체-액체 반응 촉진 기술 연구)

  • Jun Sang Park
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.45-54
    • /
    • 2023
  • In the present study, we propose new type of a spinning disk reactor(SDR) with high performance and very convenient structure to make a large scale equipment from lab-scale than the conventional one. A split-disk experimental equipment, based on new type of spinning disk reactor, has been developed to generate an energy to break a bulk of injected gas into smaller gas bubble. Several cases of an experimental observation make it to confirm that a bulk of injecting gas could be continuously break into smaller bubbles. It shows the feasibility to make a scale-up of SDR by using the characteristic of Taylor-Proudman column in rotating flow. A theoretical study on single phase liquid flow is given to predict a liquid induced shear stress, which make the present study to be self-containment.

Analysis of court rulings on involuntary manslaughter or at-fault injury due to professional negligence by pediatric nurses: a systematic content analysis study

  • Song, Sung Sook;Kim, Eun Joo
    • Child Health Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.91-102
    • /
    • 2022
  • Purpose: This study systematically analyzed cases in South Korea wherein nurses were prosecuted for involuntary manslaughter or injury due to professional negligence in pediatric care. Methods: We analyzed the precedents using the methodology of Hall and Wright (2008) and Austin (2010). Of the 618 cases retrieved from the Supreme Court Decisions Retrieval System in South Korea, we selected the 12 cases in which children were the victims and nurses were the defendants, using a case screening methodology. Results: The most frequent penalty was a fine, and newborns were the most frequent victims. The distribution of cases according to Austin's violation categories was: improper administration of medications (n=5), failure to monitor for and report deterioration (n=4), ineffective communication (n=4), failure to delegate responsibly (n=4), failure to know and follow facility policies and procedures (n=1), and improper use of equipment (n=1). Conclusion: To ensure the safety of children, nurses are required to teach and practice a high standard of care. Nursing education programs must improve nurses' awareness of their legal obligations. Nursing organizations and leaders should also work towards enacting effective nursing laws and ensuring that nurses are aware of their legal rights and responsibilities.

Risk factors of fisher on stow net fishing vessel using analysis of adjudication (재결서 분석을 통한 안강망어선에 승선하는 선원의 위험요인)

  • KIM, Wook-Sung;HYUN, Yun-Ki;LEE, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.2
    • /
    • pp.155-162
    • /
    • 2020
  • The adjudication of Korean Maritime Safety Tribunal (KMST) was analyzed to collect basic data to identify the cause of the risk that did not appear in the current data provided by the fishermen's occupational accidents of the National Federation of Fisheries Cooperative (NFFC) in stow net fishing vessel from 2015 to 2019. The personnel's carelessness was the most common in 29 out of 33 accidents (87.9%), followed by 25 cases (75.8%) of inadequacy of instructions, 24 cases (72.7%) of inadequacy of education on hazard factor, 20 cases (60.6%) of no personal protection equipment, 18 cases (54.5%) of poor guard, 17 cases (51.5%) of inadequacy of work method, 16 cases (48.5%) of absence of emergency stop button, 14 cases (42.4%) of work practice of poor safety precautions that affected more than 40% of all accidents as accident causes. These causes had a strong influence on each other, and the ratio of accident causes is high. With this relationship, accidents can be prevented or the severity of human injury can be reduced if types of accident process can be estimated with a scenario, and the key points before the accident in the scenario are switched to safe points.

Study on Fire Risk of Air Conditioner through Fire Cases (화재사례를 통한 에어컨의 화재위험성 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.70-77
    • /
    • 2017
  • As the quality of live gets better, the frequency of using air conditioner is along drastically increasing. On that matter, setting up measures of preventing increasing fire cases has been required. 43,413 fire cases occurred in last 2016, the cases occurred by electricity account for about 20%(8,655 cases). Among the electricity cases, the amount of cases occurred with air conditioner issues covers 1.5%; causes of the fire incidents vary, including incomplete contacts, short circuits, tracking, and such. In this study, we intend to investigate the case of ignition at the connection point where the power cord connected to the outdoor unit is arbitrarily connected during the air conditioner installation process, and to propose preventive measures against the cause in order to reduce the damage of life as well as the property from electric fire incidents.

Developing the Accurate Method of Test Data Assessment with Changing Reliability Growth Rate and the Effect Evaluation for Complex and Repairable Products

  • So, Young-Kug;Ryu, Byeong-Jin
    • Journal of Applied Reliability
    • /
    • v.15 no.2
    • /
    • pp.90-100
    • /
    • 2015
  • Reliability growth rate (or reliability growth curve slope) have the two cases of trend as a constant or changing one during the reliability growth testing. The changing case is very common situation. The reasons of reliability growth rate changing are that the failures to follow the NHPP (None-Homogeneous Poisson Process), and the solutions implemented during test to break out other problems or not to take out all of the root cause permanently. If the changing were big, the "Goodness of Fit (GOF)" of reliability growth curve to test data would be very low and then reduce the accuracy of assessing result with test data. In this research, we are using Duane model and AMSAA model for assessing test data and projecting the reliability level of complex and repairable system as like construction equipment and vehicle. In case of no changing in reliability growth rate, it is reasonable for reliability engineer to implement the original Duane model (1964) and Crow-AMSAA model (1975) for the assessment and projection activity. However, in case of reliability growth rate changing, it is necessary to find the method to increase the "GOF" of reliability growth curves to test data. To increase GOF of reliability growth curves, it is necessary to find the proper parameter calculation method of interesting reliability growth models that are applicable to the situation of reliability growth rate changing. Since the Duane and AMSAA models have a characteristic to get more strong influence from the initial test (or failure) data than the latest one, the both models have a limitation to contain the latest test data information that is more important and better to assess test data in view of accuracy, especially when the reliability growth rate changing. The main objective of this research is to find the parameter calculation method to reflect the latest test data in the case of reliability growth rate changing. According to my experience in vehicle and construction equipment developments over 18 years, over the 90% in the total development cases are with such changing during the developing test. The objective of this research was to develop the newly assessing method and the process for GOF level increasing in case of reliability growth rate changing that would contribute to achieve more accurate assessing and projecting result. We also developed the new evaluation method for GOF that are applicable to the both models as Duane and AMSAA, so it is possible to compare it between models and check the effectiveness of new parameter calculation methods in any interesting situation. These research results can reduce the decision error for development process and business control with the accurately assessing and projecting result.

A Study on Need for Safe Baseline Isolation Standard for Chemical Plant Equipment (화학공장 설비의 안전한 격리 표준 필요성에 대한 연구)

  • Su-Ji Choi;Sang-Gil Kim;Gyu-Sun Cho
    • Industry Promotion Research
    • /
    • v.8 no.4
    • /
    • pp.37-46
    • /
    • 2023
  • Due to the aging, advancement, and complexity of chemical facilities, non-routine work such as facility inspection, repair, or maintenance work is increasing. Of the 1,483 accidents that occurred over the past 10 years at chemical product manufacturing sites subject to PSM, accidents that occurred during non-routine work accounted for 56% (932 Cases) of the total. It can be seen that more accidents occur during non-routine work than during routine work. In particular, in order to improve the economy and efficiency of factory operation, there are cases where some facilities are stopped without stopping the entire factory and then inspection, repair, or maintenance work is performed while isolated from the operating facilities. Therefore, first, a safe isolation method must be selected by establishing an isolation standard (Baseline Isolation Standard) based on the chemicals handled, operating conditions, and risk level of the equipment in the chemical plant. Second, since current domestic laws and standards do not suggest the need for specific quarantine standards, it is necessary to institutionalize the preparation of quarantine standards. Technical and institutional improvements are needed to prevent fires, explosions, and poisoning accidents caused by leaks of chemical substances.