• 제목/요약/키워드: enzyme-linked immunosorbent assay (ELISA)

검색결과 744건 처리시간 0.03초

Quantitation of Plasma Apolipoprotein A-I with a Sandwich Type Enzyme-Linked Immunosorbent Assay Using Monoclonal Antibodies

  • Lee, Min-Gyu;Kang, Jae-Seon;Jeong, Jae-Yeon;Jue, Dae-Myung;Kim, Hack-Joo
    • BMB Reports
    • /
    • 제30권6호
    • /
    • pp.390-396
    • /
    • 1997
  • A sandwich-type enzyme-linked immunosorbent assay (ELISA) for the quantification of human apolipoprotein A-I (apoA-I) was developed using monoclonal antibodies. For this assay, we used three monoclonal antibodies to trap and detect apo A-I. HDAI16 and HDA15 monoclonal antibodies were used for trapping apoA-I and HDAI8 monoclonal antibody was for detecting apoA-I. These three monoclonal antibodies were produced by immunizing mice with high density lipoprotein (HDL) isolated from human plasma. By immunoblot analysis, these three monoclonal antibodies were specific to apoA-I and showed no cross-reactivities with other plasma proteins. The results of competition assays for epitope cross-reactivity test also verified that these monoclonal antibodies identified separate and distinct epitopes on HDL and apoA-I. Affinity constants of monoclonal antibodies were measured by ELISA. Their association constants ranged from $10^7$ to $10^8$ $M^{-1}$. For this assay, pure apoA-I was isolated by affinity chromatography using monoclonal antibodies. In this sandwich assay, the amount of HRP-labeled HDAI8 bound to apoA-I trapped by HDAI16 and HDAI5 was proportional to apoA-I concentration in the range of 0 to 500ng/ml. ApoA-I concentration in plasma was calculated from the linear regression equation of standard curve. The precision and reliability of the assays are reflected in the low intra-and interassay coefficients of variation that averaged 3.25% and 4.30%, respectively. This assay is sensitive, simple, reproducible, convenient in incubation interval, and does not use radioisotope: thus it can be widely applied in clinical laboratories.

  • PDF

Legionella Pneumophila 검출을 위한 효소면역측정 스트립 센서 (An Enzyme-linked Immunosorbent Assay Strip Sensor for the Detection of Legionella Pneumophila)

  • 김영기;박소정
    • 공업화학
    • /
    • 제25권5호
    • /
    • pp.544-547
    • /
    • 2014
  • 본 연구에서는 효소면역 분석법(enzyme-linked immunosorbent assay)과 면역크로마토그래픽 기법을 결합하여 Legionella pneumophila 검출을 위한 면역스트립을 제작하였다. 면역스트립은 4종의 멤브레인을 이용하여 제작하였다. 니트로셀룰로오스 멤브레인은 포획항체를 고정화하여 신호 발생을 일으키기 위해 사용되었고, 두 종류의 유리섬유 멤브레인은 각각 중합체 패드와 시료주입 패드로 사용되었다. 셀룰로오스 멤브레인은 모세관 현상으로 시료흐름을 유도하는 흡수 패드로 이용하였다. 샌드위치 면역반응과 효소반응에 의해 30 min 이내에 생성된 발색신호는 정성 및 정량 분석이 가능하였다. 분석조건 하에서 육안에 의한 정성 검출뿐 아니라, $1.3{\times}10^3-1.3{\times}10^6CFU/mL$ 범위의 L. pneumophila 농도를 디지털카메라와 자체 제작된 소프트웨어를 이용하여 정량적으로 분석할 수 있었다.

Zearalenone ELISA kits의 응용에 관한 연구 (Studies on practical application of zearalenone ELISA kits)

  • 윤화중;김태종;이승윤;제갈준;윤지병
    • 대한수의학회지
    • /
    • 제38권2호
    • /
    • pp.297-303
    • /
    • 1998
  • For the extraction and measurement of zearalenone in the corn, bean, wheat and barley contaminated with Fusarium graminearum, the zearalenone-oxime, zearalenone-oxime BSA and zearalenone monoclonal antibodies were studied to develop and apply the direct competitive enzyme linked immunosorbent assay (ELISA). The extraction range of zearalenone with the monoclonal antibodies produced in this experiment was 10ng to 500ng/g feed and the 50% inhibition value was 50ng/ml. The mean recoveries of zearalenone artificially spiked in the ground corn were 89%. The specificity of F-2 monoclonal antibody for the analogues was favorable for the direct competitive ELISA. The result of the experiment showed the zearalenone in the corn, bean, wheat and barely naturally contaminated with the mold would be suitable for extraction and measurement with the monoclonal antibodies.

  • PDF

산란계 밀집지역에서 혈구응집억제반응과 효소면역측정법을 이용한 가금인플루엔자 혈중항체가의 비교 조사 (Comparative study on avian influenza virus antibody titer by hemagglutination inhibition test and enzyme-linked immunosorbent assay in the mass zone layer)

  • 이정원;엄성심;이성재;서이원;서석열;정동석;송희종
    • 한국동물위생학회지
    • /
    • 제27권1호
    • /
    • pp.81-87
    • /
    • 2004
  • This study was conducted to investigate the similarity between hemagglutination inhibition (HI) test and enzyme-linked immunosorbent assay(ELISA), the HI titer and mean ratio S/P ratio) of avian influenza virus. To perform this study, the 1,457 sera of layers 21 farms in May, July and September, respectively. As a result of HI test, positive rates were 480 to 422 (92.1%) in May, 494 to 394(79.8%) in July and 483 to 402(83.2%) in September, and the mean antibody titer were 4.6, 4.3, 4.0 to 0.3 decreased, respectively. The positive rates by ELISA, 480 to 475(99.0%) in May, 494 to 485(98.2%) in July, 483 to 472(97.7%) in September, and the mean S/P ratio were 2.319, 2.557 and 2.380, respectively. The result of HI test and ELISA positive 480 to 422(92.1%), 475(99.0%), 494 to 394(79.8%), 485(98.2%) and 483 to 402(83.2%), 472(97.7%). Therefore, ELISA was shown more sensitive compare the HI titers.

Quality Evaluation of Five Commercial Enzyme Linked Immunosorbent Assay Kits for Detecting Aflatoxin B1 in Feedstuffs

  • Sun, Dan-Dan;Gu, Xu;Li, Jun-Guo;Yao, Ting;Dong, Ying-Chao
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권5호
    • /
    • pp.691-696
    • /
    • 2015
  • The objective of this study was to evaluate the quality of five commercial enzyme linked immunosorbent assay (ELISA) kits (A, B, C, D, and E) from different suppliers for detecting aflatoxin $B_1$ ($AFB_1$). $AFB_1$-free corn samples supplemented with different levels of $AFB_1$ (5, 10, and $20{\mu}g/kg$) were used as positive controls and 6 replicates of each control sample were tested to evaluate the accuracy and precision of these kits. In addition, we also evaluated the performance of these ELISA kits for $AFB_1$ in 30 feed samples, including corn, distillers dried grains with soluble, wheat samples, soybean meal, and poultry feed, which were verified by high performance liquid chromatography. Results showed that the coefficients of variation ranged from 1.18% to 16.22% in intra-plate and 2.85% to 18.04% in inter-plate for the determination of $AFB_1$. The half maximal inhibitory concentration for five kits ranged from 3.72 to $7.22{\mu}g/kg$. The quantitation limits of $AFB_1$ were all under the legal limit in China but somewhat inconsistent with kit instructions. Although the recovery rate of four of the five kits were either less than 90% or more than 110%, all these values were acceptable in practice. Two kits had high false positive rates (C and E). In conclusion, our results revealed that the qualities of five tested ELISA kits were significantly different.

Enzyme Linked Immunosorbent Assay를 이용한 진엽독소 검출에 관한 연구 (Studies on the Mycotoxin Detection by an Enzyme Linked Immunosorbent Assay)

  • 염곤;유승북;이장훈
    • Environmental Analysis Health and Toxicology
    • /
    • 제5권3_4호
    • /
    • pp.29-36
    • /
    • 1990
  • Aflatoxins, produced by strains of Aspergillus flavus and Aspergillus parasiticus, can be found worldwide in corn, barley, peanuts, and other commodities. Among this group of toxins, aflatoxin B$_1$was realized to be one of the most potent environmental carcinogens, mutagens and teratogens. It is routinely monitored by methods such as thin layer chromatography, liquid chromatography, fluorodensitometric technique and radioimmunoassay. However, these assays are expensive, necessitate radioactive reagents, and require overnight incubation. In this study, the determination of fungal flora in several sorts cereals has been carried out in order to obtain an appropriate information of the population of fungi. The quantitative analysis of aflatoxin B$_1$has been carried out by High Performance Liquid Chromatography (HPLC) method and Enzyme Linked Immunosorbent Assay (ELISA). The results were summarized as follow: 1) From the 100 samples,313 colonies of fungi were isolated. Among the 313 colonies, 274 were possible to identify into 11 genera. The identified genera were Aspergillus Penicillium, Mucor, Rhizopus, Alternaria, Cladosorium, Fusarium, Circinella, Chrysosporium, Paecilomyces and Phoma. 2) Six of Aspergillus flavus were aflatoxin-producing strains. Aspergillus flavus isolated from sample barleys was contained the highest content (21.8 $\mu\textrm{g}$/ml) of aflatoxin B$_1$. 3) The yield of aflatoxin B$_1$-oxime compound was appromately 75%. Aflatoxin B$_1$-oxime-Human serum albumin was approved by formal consent as complete antigen. 4) Direct competitive ELISA permitted detection of 0.15 ng levels. In the quantitative microanalysis, ELISA was superior to HPLC method.

  • PDF

Establishment for Improving Productivity of Cattle by Fecal Steroid and Milk Urea Nitrogen Analysis - I. Development of Enzyme-linked Immunosorbent Assay for Progesterone and Milk Urea Nitrogen Analysis in Cattle

  • Chung-Boo Kang;Woo-Song Ha;Ji-In Kwon;Young-Sang Yu;Chul-Ho Kim;Soo-Dong Kwak
    • 대한의생명과학회지
    • /
    • 제8권4호
    • /
    • pp.235-244
    • /
    • 2002
  • This study was carried out to determine the blood and milk progesterone by enzyme-linked immunosorbent assay (ELISA), and milk urea nitrogen (MUN) in cows. MUN and protein concentration were determined using automated infared procedures. The optimum conditions of ELISA system was investigated including the first and second antibody titres, bound percent, and enzyme conjugate and also the factors on MUN and protein concentration by sampling procedures and addition of preservatives. Progesterone antibodies did not react to pregnenlone, testosterone, estrone, estradiol-l7$\beta$, aldosterone, cortisol, corticosterone and 11$\alpha$-dehydroxycortisone (DOC), but reacted with only progesterone. The intra and inter-assay coefficient of variation 4.5%, 6.1~9.4% when used of bovine serum. The morning, MUN concentration (17.6$\pm$2.8 mg/100 ml) in the 13 herds was similar to that of evening MUN concentration of the lactating cows from the same herd. A significant relationship between morning and evening milk samples of upper parameters was found r=0.93. Difference in MUN concentration with sampling procedures and using of preservatives were investigated.

  • PDF

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권2호
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

Evaluation of enzyme-linked immunosorbent assay (ELISA) for detection of olive flounder antibodies to viral hemorrhagic septicemia virus (VHSV, genotype IVa) using two Novirhabdovirus antigens

  • Min-Seok Jang;Myung-Joo Oh;Wi-Sik Kim
    • 한국어병학회지
    • /
    • 제37권1호
    • /
    • pp.9-15
    • /
    • 2024
  • An enzyme-linked immunosorbent assay (ELISA) with two Novirhabdovirus antigens (viral hemorrhagic septicemia virus, VHSV and infectious hematopoietic necrosis virus, IHNV) was used to detect specific antibodies against VHSV from olive flounder (Paralichthys olivaceus) sera. In ELISA plates with VHSV culture supernatants (VHSV-Ag plate), optical density (OD) values for sera from olive flounder with VHS history (VHS sera) ranged from 0.64±0.36, and those of sera from fish without VHS history (non-VHS sera) ranged from 0.26±0.26. In IHNV-Ag plate, the OD values (0.43±0.28) for VHS sera were quite low compared to those in VHSV-Ag plates, while the OD values for non-VHS sera were almost similar. When the OD values for each serum were calculated by subtracting the OD values in the IHNV-Ag plate from those in the VHSV-Ag plate, the corrected OD values were significantly different between VHS sera and non-VHS sera. The results were completely in line with fish histories of VHS epizootics. It was considered that the corrected OD values may represent the true values recognized by VHSV-specific antibodies.