• 제목/요약/키워드: environmental sanitary condition

검색결과 130건 처리시간 0.02초

다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거 (Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio)

  • 최규철;윤용수;정일현
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

오존을 이용한 지하수의 철.망간 및 유기물 제거특성 (Removal Characteristics of Iron, Manganese and Organics in Ground Water Using Ozonation)

  • 선창욱;우달식;남상호
    • 환경위생공학
    • /
    • 제12권2호
    • /
    • pp.43-49
    • /
    • 1997
  • Iron and manganese problems in ground water affect far more water systems than almost any other water quality concern. The purpose of this study is to find the optimum condition of ozonation for the removal of dissolved iron, manganese and other organics in the polluted ground water. We proposed 4mg/l, 8mg/l as optimum ozone dose for the removal of $Fe^{2+},{\;}Mn^{2+}$, respectively. The removal efficiencies of $COD_{Mn}$ and $COD_{Cr}$ in ozone dose of 2mg/l - 6mg/l were about 40-50%. The removal efficiency of $NH_{3}-N$ was about 30-40% at pH8.5. In conclusion, it needs further systematic study and research concerned to treatability of $Fe^{2+},{\;}Mn^{2+}$ and biodegradability of organic compounds using Ozonation followed by biological filtration process in ground water treatment train.

  • PDF

고온 고압 유체를 이용한 고농도 시안폐액의 환경친화 기술에 관한 연구 (A Study on the Environment Familiar Technology of High Dense Cyanogen Wastewater by Using High Temperature and High Pressure Materiality)

  • 황상용;이규성
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.141-147
    • /
    • 1998
  • Under high temperature and high pressure, cyanogen disinter gration distruction mechanism brought followings results through continuous plug flow reactor system. 1. The temperature was a important reacting factor in cyanogen disintegration. Over $612.8^{\cird}K$ high disintegration rate or 99.99% was shown even under $2000{\;}mg/{\ell}$ cyanogen density. 2. The conditions of cyanogen disintegration was gained through experimenting the supercrietical condition of water in basic. To gain 99.99% disintegration rate under $1000{\;}mg/{\ell}$ early cyanogen density, the pressure showed 52.8 seconds at $523^{\cird}K$ and 84.2 atm and gained $0.56{\;}mg/{\ell}$ operating density. 3. Here is the reaction velocity formula of cyanogen disintegration by hydrolysis: This formula indicates the high possibility of cyanogen disintegration within a short time. And it also implys the potential possibility on treating NBDICOD and the technology in developing the environment cleaning progress as small size automatic controlling equipment.

  • PDF

양극산화에 의한 다공성 알루미나 막의 기체투과 특성 (Gas Permeation Characteristics of Porous Alumina Membrane Prepared by Anodic Oxidation)

  • 함영민
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.72-78
    • /
    • 1998
  • For investigation into gas permeation characteristics, the porous alumina membrane with asymmetrical structure, having upper layer with 10 nanometer under of pore diameter and lower layer with 36 nanometer of pore diameter, was prepared by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. The aluminium plate was pre-treated with thermal oxidation, chemical polishing and electrochemical polishing before anodic oxidation. Because the pore size depended upon the electrolyte, electrolyte concentration, temperature, current density, and so on, the the membranes were prepared by controling the current density, as a very low current density for upper layer of membrane and a high current density for lower layer of membrane. By control of current quantity, the thicknesses of upper layer of membranes were about $6{\;}{\mu}m$ and the total thicknesses of membranes were about $80-90{\;}{\mu}m$. We found that the mechanism of gas permeation depended on model of the Knudsen flow for the membrane prepared at each condition.

  • PDF

상수도 정수장 오이중 Alum회수 및 재활용에 관한 연구 (A Study on Alum recovery and reuse from the sludge in water treatment plant.)

  • 김관천;노기환;강영식;이치영;류일광
    • 환경위생공학
    • /
    • 제10권1호
    • /
    • pp.86-96
    • /
    • 1995
  • Alum recovery has recently gained more attention because many water utilities need to improve their sludge handling and disposal practices. As part of an overall sludge management program recovery can reduce the amount of solids and allow for reuse of the recovered Alum as a coagulant. This study was examined the effectiveness of Alum recovery from the Sludge at the D water treatment plant in Kwangju city. The results were summarized as follows 1. Alum recovery was obtained sufficiently acidification(An optimum condition was pH2-3) With $H_{2}SO_{4}$ to settled sludge. In this case recovered liquid Alum from sludge of 2.1% solids concentration at pH 2.1 was contains Aluminum $1,602mg/{\ell}$(as $Al_{2}O_{3}$ 0.3% ) and other metal of low level. 2. It was an optimum condition to all reuse of recovered Alum as a coagulant that rate of Commercial Alum:Recovered Alum=$14{\mu}{\ell}/{\ell}{\;}:{\;}200{\mu}{\ell}/{\ell}$ In a result of Jar Tests. 3. It was a result of Alum recovery from sludge, the reduction effect of amount of solids was about 57.4%. 4. If all recovered Alum were reused the reduction effect of solid wastes disposal cost and chemical drug's cost was about 22%.

  • PDF

치과위생사의 실내공기질에 의한 자각증상 특성 (A subjective symptom on indoor air quality in dental hygienist)

  • 최미숙;손부순
    • 환경위생공학
    • /
    • 제21권4호
    • /
    • pp.1-10
    • /
    • 2006
  • This research is based on self-filling survey which 220 dental hygienists who work in seoul participated on July 2006 through August 2006. This survey was analyzed the experience item and occurred time of the symptoms and the time of acute and vanish of the symptoms that dental office's working environment effects on physical subjective symptom. We suggest a plan to minimizing physical subjective symptom for health manage of dental hygienist. We found out the fact that dental hygienists were unsatisfied with hospital air condition and this polluted air condition cause them physical subjective symptom in work place. As follows analyzed results ventilation time is below the 3-times a day, this may be have some trouble in indoor air quality. The experience the symptoms level is higher then non-experience level in "Fatigue and sleepiness", "Dorsalgia, omarthralgia, cervicodynia", "Hypersensitivity", "Dry eye, itch, smarting", "Headaches" and a subjective symptom is occurred at after 11:00(am) more then 60%, 50% of the dental hygienist. This experience the symptom' pain is vanished after the work and reduced when go out the office and building, respectively. The ratio of the experience the symptoms and starting time the symptoms is anywhere from 12 noon to 4 pm (73.2%) in a day. The time of acute pain the symptoms is anywhere from 12 noon to 4 pm (78.7%) refer to the individual characteristics and work environment.

매립지의 메탄 발생억제를 위한 황산염 첨가형매립지 및 준호기성 매립지의 효율 비교에 대한 연구 (A comparative study on efficiency in the sulfate -added anaerobic landfill site and the semi-aerobic landfill site for the inhibition of methane genration from a landfill site)

  • 김정권;김부길
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.325-330
    • /
    • 1999
  • This study aims to observe the inhibition of methane generation, the decomposition of organic matter, and the trend of outflowing leachate, using the simulated column of the anaerobic sanitary landfill structure of sulfate addition type which is made by adding sulfate to a current anaerobic landfill structure, and the simulated column of semi-aerobic landfill structure in the laboratory which is used in the country like Japan in order to inhibit methane from a landfill site among the gases caused by a global warming these days, and at the same time to promote the decomposition of organic matter, the index of stabilization of landfill site. As a result of this study, it is thought that the ORP(Oxidation Reduction Potential) of the column of semi-aerobic landfill structure gradually represents a weak aerobic condition as time goes by, and that the inside of landfill site is likely to by in progress into anaerobic condition, unless air effectively comes into a semi-aerobic landfill structure in reality as time goes by. In addition, it can be seen that the decomposition of organic matter is promoted according to sulfate reduction in case of $R_1$, a sulfate-added anaerobic sanitary landfill structure, and that the stable decomposition of organic matter in $R_1$ makes a faster progess than $R_2$. Moreover it can be estimated that $R_1$, a sulfate-added anaerobic sanitary landfill structure has an inhibition efficiency of 55% or so, compared with $R_2$, a semi-aerobic landfill structure, in the efficiency of inhibiting methane.

  • PDF

과산화수소를 이용한 철(Fe)선 용해반응에 따른 청정기술 개발에 관한 연구 (A clean technology development using the iron(Fe) dissolution reaction with hydrogen peroxide)

  • 김재우
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.62-68
    • /
    • 2001
  • The advantages of hydrogen peroxide dissolution method were no discharge of noxious matter when dissolution of iron wire which used as the center supporter, reactions occur in room temperature and easy to recover dissolved iron. This study was aimed at gathering the basic data of iron wire dissolution- recovery process and proposes the reaction condition of iron wire dissolution- recovery process rind the factors influencing those reactions. The results were as follows : 1 . Hydrogen peroxide dissolution method used hydrochloric acid as the catalyst. 1. In the dissolution of iron wire(1.668 g), the condition of reaction was E1702(30 ml), HCI(20 ml) and $H_2O$(200 ml) ; time of the reaction was 18 min. P.W.(Piece weight) was 7.75 mg, and C.R. was $2.34{\;}{\Omega}$ 2. In the dissolution of iron wire(1.529 g), the condition of reaction was H7O2(30 ml), HCI(20 ml) and $H_2O$(200 ml), time of the reaction was 21 min., P.W.(Piece weight) was 7.73 mg, and C.R. was $2.35{\;}{\Omega}$. Hydrogen peroxide dissolution method used sulfuric acid as the catalyst. 1. In the dissolution of iron wire(0.834 g), the condition of reaction was $H_2O$(65 ml), $H_2SO_4$(5 ml) and 1702(5 ml) ; time of the reaction was 5 min.30 sec, P.W.(Piece weight) was 7.74 mg, and C.R. was $2.33{\;}{\Omega}$ 2. In the dissolution of iron wire(1.112 g), the condition of reaction was $H_2O$(65 ml), $H_2SO_4$(5 ml) and $H_2O_2$(5 ml) ; time of the reaction was 4 min.30 sec, P.W.(Piece weight) was 7.75 mg, and C.R. was $2.33{\;}{\Omega}$. Hydrogen peroxide dissolution method used hydrochloric acid and sulfuric acid as the catalyst confirmed a clean technology, because there were not occurred a pollutant discharged in the existing method.

  • PDF

금강수계 내 환경기초시설 운영실태에 관한 연구 (A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System)

  • 이재운;박동기;권영호
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.

수돗물의 앙금발생규명 및 저감기술방안 (Study on the alternatives to trace the origin and to diminish the sediments of drinking water)

  • 김갑수;임병진;권은미
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.17-28
    • /
    • 1994
  • There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.

  • PDF