• Title/Summary/Keyword: environmental pollutants

Search Result 2,543, Processing Time 0.028 seconds

Comparative risk analysis for priority ranking of environmental problems in Seoul

  • Kim, Ye-Shin;Lee, Yong-Jin;Park, Hoa-Sung;Lim, Young-Wook;Shin, Dong-Chun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.169-169
    • /
    • 2003
  • In Korea, there is no CRA studies and has not well known CRA and not well established their methodologies. Therefore, objectives of this study is to establish the framework of CRA consisting of health risk, economic risk and perceived risk and the detail methodologies of three main component of estimating and comparing those risks for on the three environmental problems of air pollution, indoor air pollution and drinking water contamination which being subjective to the eight sub-problems of hazardous ai. pollutants (HAPs), regulated pollutants (representative as PM10) and Dioxins (PCDDS/ PCDFs) in air pollution, and indoor ai. pollutants (IAPs) and Radon in indoor air pollution, and drinking water pollutants (DWPs), disinfection-by- products(DBPs) and radionuclides in drinking water contamination in Seoul, Korea. And then, their problems set priorities by individual and integrated risk. As a results, ranking of health risk were the following order of indoor air pollution, air pollution and then drinking water contamination, in three environmental problems and of radon, PM10, IAPs, HAPs, DWPs, Dioxins, DBPs, and then radionuclides in eight sub-problems. And that of economic risk were the same order. In the contrary, ranking of perceived risk were the following order of air pollution, drinking water contamination, and then indoor air pollution, and of HAPs, Dioxins, radionuclides, PM10, DWPs, IAPs, Radon and then DBPs.

  • PDF

A Study on the Dispersion of Air Pollutants in Local Circulation of Mesoscale (중규모 국지 순환에서 대기 오염 물질의 확산에 관한 연구)

  • 이화운;오은주
    • Journal of Environmental Science International
    • /
    • v.3 no.1
    • /
    • pp.39-47
    • /
    • 1994
  • Dispersion characteristics of air pollutants in the mountainous coastal area are investigated in considering with the mesoscale local circulations using a two dimensional numerical model with two kinds of topograpy of 500m and 300m. In the model, land-sea breezes and mountain-valley wind are mainly considered under the condition of the absence of large scale prevailing flow in the circulation analysis, and the pollutants dispersion is traced by the Lagrangian methods. According to the results, the wind velocity is affected by topography and is stronger in the case of 500m height mountain than that of 300m, the Pollutants that source is near the coast transported over the mountain and dispersed to behind inland area. It is classified that the topography change control affects the wind velocity and the circulations. The pollutants that source is different transported and concentrated to behind inland and/or diffused to the sea area by the combination of the wind system with topographic changes. The results can be applied to the air pollution control with the arrangement design of industrial area and the planning of coastal developments.

  • PDF

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.

A Three Dimensional Numerical Simulation of $SO_2$ Concentration in Relation with Atmospheric Flow in Pusan Area, Korea (부산지역에서의 대기흐름과 관련된 $SO_2$농도 3차원 수치모의)

  • 장은숙;이화운
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.359-367
    • /
    • 1997
  • The Characteristics of atmospheric flow and dispersion of air pollutants in the mountainous coastal area were studied using three-dimensional model by the combination of land/sea breezes and transport. It was then applied to Pusan city. As the urban area considered In this study is located in a mountainous coastal area, the atmospheric flow is strongly affected by the land/sea breezes and mountain/valley winds. The typical effects of land/sea breezes on the dispersion and the characteristics of pollutants movement in the region were analysed. The model has been proved to be an useful tool to prodict real time air pollutants transport as shown by the results of application studies In Pusan, Korea which Is an urbanized coastal area with mountainous topography. It was found that the pollutants are differently transported and concentrated as going Inland by the Influence of the sea breeze with topographic changes. By comparing the pollutants concentrations of the stimulated results with those of the observational results, It is shown that stimulated results in this study are in qualitative agreement with observational ones.

  • PDF

The Trend of the Concentrations of the Criteria Pollutants over Seoul (서울의 대기환경기준물질 농도 추이)

  • Kim, Yong Pyo;Yeo, Min Ju
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.369-377
    • /
    • 2013
  • The trends of the criteria air pollutants' concentrations over Seoul are reviewed, relative contributions of major sources are discussd, and directions for future air quality management are suggested. It was shown that the yearly average concentrations of the criteria air pollutants except nitrogen dioxide and ozone have decreased significantly over the last three decades. Though the concentration of nitrogen dioxide has not decreased, the concentration of $NO_x$ has decreased significantly. The major reason for the reduction of the criteria air pollutants has been strict government regulations such as establishment of strict emission standards and switch to cleaner fuels. However, it is not clear the major reason (s) for the reduction of the $PM_{10}$ concentration. It is suggested that to further reduce the concentrations of secondary air pollutants such as ozone and $PM_{2.5}$, understanding the major chemical pathways for them is essential. In addition, influence from outside Seoul should be quantified and effectively controlled.

Rejection Properties of Hydrophilic Solutes and Micro Organic Pollutants with a Hollow Fiber NF Membrane (중공사 나노여과 막분리를 이용한 친수성 용질과 미량 유기 오염물질의 배제 특성)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.205-210
    • /
    • 2005
  • There has been a growing interest in NF membrane for drinking water treatment, because it can remove simultaneously both hardness and hazardous micro pollutants such as pesticides and THM precursors. In this work, a hollow fiber NF membrane known as a composite membrane was employed for the rejection properties of both hydrophilic solutes and micro organic pollutants, where the former was used to evaluate the molecular sieving effect of this membrane and the latter was employed for the investigation of solute-membrane interaction as hydrophobic materials. This membrane effectively rejected the hydrophilic solutes and the permeation of them was mainly controlled by the molecular sieving effects such as molecular weight and molecular width. In the case of all micro organic pollutants, the rejections were varied from 42.2% for Simazine to 91.6% for Malathion, and the parameters related to the steric hindrance could significantly play an important role in the rejection. In the batch type adsorption experiments, all micro organic pollutants were entrapped mildly on the membrane in spite of lower degree compared with that of aromatic compounds, and they were correlated with log K.

A Study on the Characteristic Trace Organic Pollutants in the Industrial Wastewater (산업폐수중 미량유기오염물질 배출 특성)

  • Chung, Y.H.;Kim, S.C.;Shin, S.K.;Kang, I.G.;Lee, J.I.;Lee, W.S.;Lee, J.B.
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.62-72
    • /
    • 1998
  • This study was performed to characterize the trace organic pollutants in the industrial wastewater and to establish the database of the trace organic pollutants. The four manufacturing industries, which are refined petroleum, industrial chemicals, rubber & plastics and fabricated metals, were surveyed. The wastewater and discharging water of these 30 factories are analyzed to characterize the trace organic pollutants. In industrial chemicals, the kinds of products and organic pollutants are very various. Therefore to select the characteristic organic pollutants in this categories are also very difficult. In industrial chemicals, the gas chromatograpic peak patterns of wastewater are represented the various type according to their products, therefore the typical patterns of the characteristic organic pollutants could not be obtained because the kinds of manufactured goods and organic pollutants are very various. In refined petroleum, the effluent is discharged in the distillatory process of atmosphere pressure and contained the saturated hydrocarbons, phenol compounds, benzene compounds and naphtalene compounds. The saturated hydrocarbons peaks from $C_{15}$ to $C_{35}$ are represented the typical oil patterns by the uniform intervals therefore the peak can be easily distinguished. In rubber & plastics, the wastewater is discharged in the washing process which contains the additives. The problem of wastewater is not serious because the manufacturing process is not produced the effluent or the produced cooling water is recycled in that process.

  • PDF

A Study on the Environmental Professionals′ Risk Perception towards Some Pollution Issues (일부 환경 전문가들의 환경 위해성 인식도에 관한 연구)

  • 신동천;박종연;임영욱;김진용;장은아;박성은
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.4
    • /
    • pp.175-187
    • /
    • 1999
  • To investigate the risk perception of environmental issues, two consequtive surveys were conducted to environmental professionals using a standardized questionnaire from September to October in 1999. The number of subjects were 72 for the first survey and 68 for the second one. The questionnaire was consisted of items such as the degree of environmental pollution in Korea, risk perception of some issues on human health and ecosystem, and seriousness of the problems in the real situation in Korea. For the degree of environmental pollution in Korea, the average risk rating in the second test (7.4 point) was significantly higher than that in the first test (7.2 point). The risk perception on the general human health and ecosystem, and the seriousness in Korea situation were analyzed in the order of ′air pollution′, ′water pollution′,′soil contamination′,′waste′,′toxic chemical pollutants′,′food contamination′,′ocean contamination′, ′odor pollution′, and ′noise pollution′. Also ′toxic chemical pollutants′ problem was perceived to be the highest risk on general human health or ecosystem, and on present situation in Korea. ′Automotive vehicle exhaust′ problem was perceived to be the most severe environmental problems among specific 30 items. ′Industrial source air pollution′,′toxic air pollutants′, and ′domestic and industrial source pollutants to surface water′ were relatively severe environmental problems comparing to other problems. The pollution issues were classified into four categories by two aspects of perception; risk in general setting and seriousness in Korea situation. If the issues were highly serious in Korea and low risk perception in general setting then it is named "the Korea-specific group". Those that were all high score in two aspects, named "the Common group". Those that were all low in two aspects, named "the Nonsignificant group". And the issues were high risk perception in general setting and low seriousness in Korean situation, named "the Latent group".

  • PDF

Characteristics of the Pollutants Ronoff on the Tamjin A and B Watershed with Discharge Variation (유량변동에 따른 탐진 A와 B유역에서의 오염물질 유출 특성)

  • Park, Jinhwan;Lim, Byungjin;Jung, Jaewoon;Kim, Daeyoung;Oh, Taeyoun;Lee, Dongjin;Kim, Kapsoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.917-925
    • /
    • 2012
  • In this study, we report the runoff characteristics of pollutants for Tamjin A and B watershed in Tamjin river basin using statistical analysis, such as correlation analysis and regression equation. Flow rate and water qualtiy data collected from 2 sampling sites(Tamjin A and B watershed) during 3 years(2009~2011) were analyzed for biochemical oxygen demand(BOD), total nitorgen(TN), total phosphorus(TP) and suspended solid(SS). The results showed that strong correlations were observed between flow rate and SS in Tamjin A, while weak correlations were observed among the BOD, TN, and TP. In Tamjin B, strong correlations were observed among the flow rate, SS and T-P except BOD and TP. Meanwhile, the values of $R^2$ for regression equations between flow rate and pollutants load were greater than 0.7. Results of these statistics indicated that there was a good agreement between flow rate and pollutants load. Also, the flow rate exponents of regression equations for BOD, TN, and TP were smaller than 1 in Tamjin A. In Tamjin B, flow rate exponents of regression equation for BOD and TP were smaller than 1. These results indicated that concentrations of BOD, TN, TP in Tamjin A and concentrations of BOD and TP were decreased as the flow rate was increased. This means that rater than nonpoint sources, point sources affect BOD, TN and TP in Tamjin A and BOD and TP in Tamjin B.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.