• Title/Summary/Keyword: environmental efficiency

Search Result 7,222, Processing Time 0.036 seconds

The Energy-efficiency Analysis of Companies in Korea Using DEA (DEA를 활용한 국내 기업의 에너지효율성 분석)

  • Moon, Hana;Min, Daiki
    • Korean Management Science Review
    • /
    • v.32 no.3
    • /
    • pp.37-54
    • /
    • 2015
  • This paper suggests energy efficiency which can be the foundation on corporate profit and effective energy management following by change of global climate and of energy-related regulations. Using comparable financial information and information related to energy use, an DEA (Data Envelopment Analysis) model has been used to identify energy efficiency with DMU (Decision Making Unit)s which are companies subjected to reduce greenhouse gas emission in 2009. Through this research, different from existing researches, environmental variables which can influence on energy efficiency are identified. The results show as follows. First, most of companies follow IRS, which means scale of economy exists among units so that they have more opportunity to increase efficiency by increasing scale of inputs. Second, this research identified that depending on the difference of environmental characters such as the emission structure and the size of companies, energy efficiency of the companies turns out differently.

Operational conditions of electrochemical oxidation process for removal of cyanide (CN-) in real plating wastewater

  • Zhao, Xin;Jang, Minsik;Cho, Jin Woo;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.217-222
    • /
    • 2020
  • An electrochemical oxidation process was applied to remove cyanide (CN-) from real plating wastewater. CN- removal efficiencies were investigated under various operating factors: current density and electrolyte concentration. Electrolyte concentration positively affected the removal of both CN- and Chemical Oxygen Demand (COD). As the electrolyte concentration increased from 302 to 2,077 mg Cl-/L, removal efficiency of CN- and COD increased from 49.07% to 98.30% and from 23.53% to 49.50%, respectively, at 10 mA/㎠. Current density affected the removal efficiency in a different way. As current density increased at a fixed electrolyte concentration, CN- removal efficiency increased while COD removal efficiency decreased, this is probably due to lowered current efficiency caused by water electrolysis.

Analysis of Economical efficiency for renewable energy in Steam Power Plant (신재생에너지 적용에 따른 화력발전 경제성분석)

  • Choi, Kyoung-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2014
  • Since the Renewable Portfolio Standard (RPS) would be started in 2012, the use of renewable energy should be 11% of total energy use including bio-fuel in 2030. The economic efficiency for renewable energy in B power plant was considered with the bio-diesel, wind power and solar power. The Net Present Value (NPV) and Benefit/Cost Ratio(BC) were used for the economic efficiency with the cost and benefit analysis. In case of bio-diesel, the cost resulted from the fuel conversion and the benefit would be created with trade and environmental improvement. With regard to wind power and solar power, the construction cost would be required and benefit factors would be same as the bio-diesel. The wind power was the best of economic efficiency of renewable energy as the results of NPV and BC ratio. Whereas, the market of wind power was very popular and the techniques of wind power has been developing rapidly.

Evaluation on Removal Efficiency of Cryptosporidium using Surrogate in Pilot Plant of Conventional Water Treatment Process (표준정수처리 파일럿에서 Cryptosporidium 유사체를 이용한 Cryptosporidium 제거효율 평가)

  • Park, Sangjung;Chung, Hyenmi;Choi, Heejin;Jun, Yongsung;Kim, Jongmin;Kim, Taeseung;Chung, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.399-405
    • /
    • 2010
  • In order to quantify removal efficiency of Cryptosporidium in water treatment process and evaluate factors influencing removal efficiency of Cryptosporidium in each step of water treatment process, large pilot plant system ($100m^3/day$) and Cryptracer, surrogate of Cryptosporidium, were used. The removal efficiency of Cryptracer was around 0.8~1 log in coagulation process and 3.3~4.8 log in sand filtration process under ordinary environmental conditions. Factors influenced removal efficiency of Cryptracer were high fluctuate turbidity and water temperature. High fluctuate turbidity made difficult to adjust optimum PAC concentration, caused to drop removal efficiency of coagulation process (0.5 log). Inadequate coagulation process influenced to sand filtration process (2.1 log), caused to decline of removal efficiency in the whole process (2.6 log). Low temperature below $2^{\circ}C$ also influenced coagulation process (0.6 log). Therefore, It is shown that careful attention in the control of Cryptosporidium is needed in flood period, when high fluctuate turbidity would be, and winter period of low temperature.

Pre-validation of Colony Forming Efficiency Assay for Assessing the Cytotoxicity of Nanomaterials (나노물질의 세포독성 평가법으로 Colony Forming Efficiency Assay에 대한 검증연구)

  • Jo, Eunhye;Lee, Jaewoo;Park, Sun-Young;Kim, Pilje;Choi, Kyunghee;Eom, Igchun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • Objectives: The cytotoxcities of Au, Ag, SWCNT, $SiO_2$, and ZnO nanomaterials were evaluated in order to assess their potential toxicological effects in in vitro cell models using colony forming efficiency (CFE) assay. Methods: The CFE assay of the test materials was carried out on Hep G2 cells. The size distribution of nanomaterials was studied by transmission electron microscopy (TEM). Changes in cell viability after treatment with a toxicant will result in a decreased number of colonies formed in comparison to solvent. Results: The TEM images show that all the particles except SWCNT and ZnO can be considered approximately spherical. The gold and $SiO_2$ nanoparticles show no response (no toxicity) in concentration response experiments. A statistically significant toxic effect was found in Hep G2 cells treated with Ag, SWCNT and ZnO nanomaterials. Conclusion: In this study, we considered CFE assay to be a promising test for screening studies for cytotoxicity with physicochemical analysis.

Life Cycle Assessment and Eco-efficiency Analysis for the Resource-circulation Network of Waste Heat Generated from Industrial Process (공정폐열의 자원순환 네트워크 구성을 위한 전과정 평가 및 생태효율성 분석)

  • Shin, Choon-Hwan;Park, Do-Hyun;Kim, Ji-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.281-289
    • /
    • 2013
  • For the purpose of evaluating the eco-efficiency(EE) on surplus heat generated from industrial process, techniques of life cycle assessment are adopted in this study. Because it can be indicated both environmental impacts and economic benefits, EE is well known as a useful tool for symbiosis network on the sustainable development of new projects and businesses. To evaluate environmental impacts, the categories were divided into two areas of resource depletion and global warming potential. It can be seen that environmental impact increased a little but much higher economic benefit on the company, environmental performance and economic value were improved on the apartment by the district heating, respectively. In result, eco-industrial park(EIP) project on surplus heat should be found sustainable new business because the EE was in the area of fully positively eco-efficiency and, moreover resource depletion was taken place than the reduction of greenhouse gas.

Eco-efficiency of Energy Symbiosis for the Energy Network of Surplus Heat

  • Shin, Choon-Hwan;Kim, Ji-Won
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.545-553
    • /
    • 2012
  • Eco-efficiency considers both environmental impacts and economic values. It is a useful tool for communicating with stakeholders for business decision making. This study evaluated the eco-efficiency factor (EEF) for the energy network of a dyeing company that supplies surplus heat to a neighboring apartment during the night. This symbiosis network is one of the eco-industrial park (EIP) projects in Korea and aims to benefit local residents and the industrial complex by utilizing surplus heat. In this study, two categories were annualized. The first quantified environmental burden based on $CO_2$ emissions and quantified product value in terms of steam sales. The second used a variety of environmental factors, such as fossil fuel, water and waste, to quantify environmental burden and used steam sales to quantify value. The EEF of the symbiosis network was 1.6, using the global warming impact, and determined using the multiple variable, was 1.33. This study shows that the EEF depends on variable details of environmental burden but the values of this project were very high contrast to other business or EIP project.

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

Evaluation of field application of biocover and biofilter to reduce landfill methane and odor emissions (매립지 메탄 및 악취 배출 저감을 위한 바이오커버 및 바이오필터의 현장적용 평가 연구)

  • Chae, Jeong-Seok;Jeon, Jun-Min;Oh, Kyeong-Cheol;Ryu, Hee-Wook;Cho, Kyung-Suk;Kim, Shin-Do
    • Journal of odor and indoor environment
    • /
    • v.16 no.2
    • /
    • pp.139-149
    • /
    • 2017
  • In order to reduce odor and methane emission from the landfill, open biocovers and a closed biofilter were applied to the landfill site. Three biocovers and the biofilter are suitable for relatively small-sized landfills with facilities that cannot resource methane into recovery due to small volumes of methane emission. Biocover-1 consists only of the soil of the landfill site while biocover-2 is mixed with the earthworm casts and artificial soil (perlite). The biofilter formed a bio-layer by adding mixed food waste compost as packing material of biocover-2. The removal efficiency decreased over time on biocover-1. However, biocover-2 and the biofilter showed stable odor removal efficiency. The rates of methane removal efficiency were in order of biofilter (94.9%)>, biocover-1(42.3%)>, and biocover-2 (37.0%). The methane removal efficiency over time in biocover-1 was gradually decreased. However, drastic efficiency decline was observed in biocover-2 due to the hardening process. As a result of overturning the surface soil where the hardening process was observed, methane removal efficiency increased again. The biofilter showed stable methane removal efficiency without degradation. The estimate methane oxidation rate in biocover-1 was an average of 10.4%. Biocover-2 showed an efficiency of 46.3% after 25 days of forming biocover. However, due to hardening process efficiency dropped to 4.6%. After overturn of the surface soil, the rate subsequently increased to 17.9%, with an evaluated average of 12.5%.

Estimation of CH4 oxidation efficiency in an interim landfill cover soil using CO2/CH4 ratios

  • Park, Jin-Kyu;Lee, Won-Jae;Ban, Jong-Ki;Kim, Eun-Cheol;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.191-197
    • /
    • 2015
  • The first objective of this study was to discuss the applicability of the $CO_2/CH_4$ ratio method in order to assess $CH_4$ oxidation efficiency. To achieve this objective, a comparison between $CO_2/CH_4$ ratios and the mass balance method was conducted. The second objective of this study was to estimate the $CH_4$ oxidation efficiency in an interim landfill soil cover and assess how a $CH_4$ influx influences the $CH_4$ oxidation efficiency. The results showed that despite the $CO_2$ problems brought by respiration, the $CH_4$ oxidation efficiencies obtained by the $CO_2/CH_4$ ratio method led to similar results compared to the mass balance method. In this respect, the $CO_2/CH_4$ ratio method can be an indicator of the $CH_4$ oxidation efficiencies for landfill cover soils. The $CH_4$ oxidation efficiencies derived in this study through the $CO_2/CH_4$ ratio method ranged between 46% and 64%, and between 41% and 62% through the mass balance method. The results imply that the Intergovernmental Panel on Climate Change's (IPCC) default value of 10% for the $CH_4$ oxidation efficiency is an underestimation for landfill cover soils. $CH_4$ oxidation efficiency tends to be negatively correlated with $CH_4$ influx. Therefore, $CH_4$ influx reaching a landfill cover should be limited in order to increase the $CH_4$ oxidation efficiency.