PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석 (Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

Efficient Cross-Room Switch Mechanism for Indoor Room-Division-Multiplexing Based Visible Light Communication Network

  • Huang, Zhitong;Xiong, Jieqing;Li, Jianfeng;Ji, Yuefeng
    • Journal of the Optical Society of Korea
    • /
    • 제19권4호
    • /
    • pp.351-356
    • /
    • 2015
  • Visible light communication (VLC) is considered to be an attractive scheme to realize the broadband wireless communication for an indoor environment. We present a room division multiplexing (RDM) mechanism for an indoor multi-room VLC network, which utilizes the spatial position of the LED lamp in different rooms as a novel dimension of network resource for multiplexing, and thus the network capacity is increased. In such a network, the service interruption caused by user cross-room movement is an important problem, and we propose a double-area-positioning based cross-room switch solution. An experimental platform demonstrates the RDM-deployed VLC network, and validates the performance of the presented switch mechanism.

분만실 간호사의 근무 경험에 관한 현상학적 연구 (Work Experiences of Delivery Room Nurses: A Phenomenological Study)

  • 이윤정
    • 여성건강간호학회지
    • /
    • 제23권2호
    • /
    • pp.78-88
    • /
    • 2017
  • Purpose: This study aimed to understand meaning and essentials in work experiences of delivery room nurses. Methods: A phenomenological perspective was used for this qualitative research. Ten delivery room nurse with more than 3 years of work experience participated in this study. Data were collected through individual in-depth interviews with the nurses, between December 2012 and April 2013. Data were analyzed using Colaizzi's method. Results: Nine theme clusters and four categories emerged from the data as follows: 1) factors influencing career decision-making, 2) gap between reality and expectations, 3) difficulties with working in the delivery room, and 4) motivation to work in the delivery room. Conclusion: Based on the results of this study, strategies to improve working environment of the delivery room nurses are necessary. Also, better policy are required to firmly establish the role of the delivery room nurses' role as recognized professionals.

대학(大學) 건축학과(建築學科) 재학생(在學生)의 CAD 환경(環境) 및 인식(認識)에 관한 연구(硏究) - 사례대학의 재학생을 대상으로 - (A Study on Environment and Perception of CAD by Undergraduate Students in the Dept. of Architecture - Case study on Undergraduate Students -)

  • 유창균;박성하
    • 한국디지털건축인테리어학회논문집
    • /
    • 제1권1호
    • /
    • pp.24-30
    • /
    • 2001
  • This study conducts a questionnaire with undergraduate students in the Dept. of Architecture who will lead the architectural field in future, examines environment and perception of CAD in their home and universities and aims at supplying the data required for setting CAD educational index and building its use environment, and it could obtain the following results. Individual CAD environment of undergraduate students in the Dept. of Architecture reach a considerable level in hardware part, but they don't have the same level in software part as the hardware and use illegal copy programs. It is shown that they spend their time in using CAD for five to eight hours a week and its main purposes are to perform a project related to architectural design or make report requiring drawing. Major places using CAD are CAD room in university or public PC room equipped with CAD compared to their own houses and most of them have a negative recognition of the convenience of its use. Their satisfaction with CAD use is considerably high and when they submitted their assignments of architectural design project by means of CAD, they had a positive evaluation from their professors and they have such hopes that 'Korean Support Strengthening', 'lowering price through version supply for students' and 'diversification of design symbol' in CAD S/W, and especially, most of respondents have an intention to purchase the original goods when version only for students will be marketed in future. Accordingly, for a qualitative improvement of CAD environment for undergraduate students in the Dept. of Architecture, universities must be equipped with the various types of CAD S/W and Applications and students' opportunity to access them should be increased. In addition, a method which can enhance using convenience of CAD room and PC room is required and CAD related S/W developers must market the version for students which consider the reality of undergraduates in Korea properly with an appropriate price level in order to settle a sound S/W culture.

  • PDF

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태 (The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students)

  • 최윤정;김운학
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구 (A Study on the Change of Indoor Thermal Environment According to the location of Blinds)

  • 황덕수;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

대전지역 아파트 거주자의 주거의식에 관한 조사연구 (Survey on Apartment Dwellers' Perception of Housing Environment in Daejeon City)

  • 최병숙;강인호;박정아;장혜선;정미현
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.339-344
    • /
    • 2008
  • The purpose of this study was to find out the residents' perceptive opinions of apartment housing environment and to contribute to develop a apartment unit plan in Daejeon City. This research was performed by a questionnaire survey method, 464 data was collected from apartment residents lived in about $85m^2$ unit with 3 rooms and the apartments was limited to the complexes within 3 years at Yuseong-gu and Seo-gu. By analyzing those data, findings are as follows: 1) Residents thought living room, kitchen and bathroom were importment space in a unit plan. They needed a storage function in an entrance and a intermediate room, and Anbang(materbed room) so did. L-DK plan type was very preferred. 2) Sub-kitchen was needed for a refrigerator of Kinch, the location of it was realted to a main kitchen and a uitility. the third room was needed for library, home office and storage space. 3) The enlargment remodeling of balcony was showed livingroom balcony or personal bedrooms at the time of occupancy. They needed the balcony near a kitchen or an utility to equip a storage facility. And residents were preferred to their taste rather than a choice of interior concept package services.

  • PDF

하이브리드 환경하의 인간기계시스템 제어실 평가에 관한 연구 (A Study of the Evaluation for the Control Room in Human Machine System Under Hybrid Environment)

  • 차우창;김남철
    • 대한인간공학회지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2009
  • While the operator's working environment employs the digital devices and technology which are not be fully digitalized due to its technical constraints, it has been changed to the hybrid environment in which digital and analog elements are combined. The hybrid environments need to study its characteristics and the guidelines for the proper design and evaluation purpose. This paper describes the characteristics and evaluation guidelines for hybrid environment through studying the characteristics of digital and analog environment based on the related human factor guidelines and literatures. The result of this paper would be applied for the human machine system such as main control room in nuclear power plant working under hybrid environment. And also, it may be applied for the evaluation of the generic human working environment which digital and analog elements are jointly used.

전자식 절차서 시스템의 원전제어적합성 확인 및 검증절차 (Validation and Verification Process for the Computerized Procedure System in Nuclear Power Plant Control Room)

  • 차우창
    • 시스템엔지니어링학술지
    • /
    • 제5권1호
    • /
    • pp.33-41
    • /
    • 2009
  • The analog or partly digital typed interface of main control room in nuclear power plant (NPP) is gradually being replaced to the totally digitalized interface suitable for the digital environment. SKN 3,4 Nuclear Power Plant is currently developed in such a way to employ advanced displays and controls such as computerized procedure system(CPS), large display panel(LDP), and Soft control. According to the developed design process, the main control room (MCR) of the SKN3,4 was aesthetically designed based on a design concept of the health and sustainability and technically evaluated with human factors guidelines, which somehow lack of the confidence on the evaluation for the rapidly changing digital environment. The suitable review guideline for the digitalized interface and the environment was developed such as the guideline for CPS with information displays on VDU. For the guideline development, tremendous guidelines and technical papers related to evaluation issues of digital environment has been collected, analyzed and transformed to electric database forms and then built on database management system, called Design Review Supporting System to retrieve the appropriate issues for the practical usage of evaluators-in-field.

  • PDF