• 제목/요약/키워드: environment of room

검색결과 1,741건 처리시간 0.028초

중학교 일반교실 실내음향 시뮬레이션에 관한 연구 (A Study on the Computer Simulation of Acoustic Characteristics in Middle School Lecture Room)

  • 모승준;이민섭
    • 교육시설
    • /
    • 제10권4호
    • /
    • pp.5-20
    • /
    • 2003
  • The purpose of the research on the noise of educational facilities is to build up pleasant environments by minimizing the influence on the students in the school. This study provides fundamental data for acoustic design by measuring, computer simulation and analyzing the room acoustic characteristics of the lecture room in middle school. For measurement on the factors of room acoustic, RT of lecture room and noise reductions depending on various walls of different structures were measured and analyzed. The lecture system being installed and carried out on the normal lecture room was divided into 4 types-employment of multimedia machines, employment of multimedia machines and loud speakers, employment of loud speaker, and existing verbal speaking-and SPL for each type was measured and analyzed. Based on the measured characteristics of acoustic characteristics for normal lecture room, the problems for environment of noise were understood through computer simulation, applications for improvements of performance for each facility were studied, schemes for improvements of performance by using the effects were presented, necessary fundamental data were secured, and schemes to enhance flexibility on the existing facilities of school against changing educational courses were secured.

고청정 작업환경에 적합한 방진복 디자인 개발 -파티클 발생량을 중심으로- (Design and Manufacturing of Clean Room Garments Required at Ultra Clean Environment - Based on comparative analysis of Particle Release-)

  • 박상희;송명견
    • 한국의류학회지
    • /
    • 제25권6호
    • /
    • pp.1037-1045
    • /
    • 2001
  • This research is done to design and manufacture prototype clean room garments to improve the product yield of the clean room processing. To assist the research, other papers and references on the same subject were collected for analysis. Also the researcher made interviews with the workers at the clean room. The prototype garments made for this project was compared against the commercially available clean room garments used in the industry. A set of test was conducted to measure particle release from the garments. The prototype clean room garments was manufactured after having considered all the aspects stated above, and tested for the level of particle release. The test subjects performed 4 different movements(marching, arms stretch, squat and rise, and jogging) while wearing the prototype garments and commercially available clean room garments. Particle counts produced by each movement were measured. The data collected was statistically analyzed. The followings are the result of the test. 1) Overall, the prototype garments yielded less particle release.(p<0.001) 2) It showed greatest difference of particle counts for jogging(p<0.001) and squat and rise(p<0.001). In the arms stretch test. the prototype garments was also more effective in controling the particle, however, in the marching test. no significant difference was detected. 3) The prototype garments had less particle release in upper(p<0.001), middle(p< 0.001), and lower level(p<0.01) than the commercially available clean room garments. Manufacturing a new fabric for the clean room processing is important, but this research proves that the design of the clean room garments also determines the efficiency garments in the particle control. Therefore the same fabric can perform differently according to how it is designed. Improving the design will also improve the 7article control and reduce the cost of research. Eventually, the manufacturers will increase the product yield.

  • PDF

교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로- (A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools-)

  • 전석진
    • 교육녹색환경연구
    • /
    • 제6권2호
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

다인병실 입원환자의 성별에 따른 프라이버시 특성 연구 (A Study of Gender Differences in Inpatients' Privacy Concerns in Multi-bed Hospital Room)

  • 신은경;박수빈
    • 한국실내디자인학회논문집
    • /
    • 제27권1호
    • /
    • pp.80-87
    • /
    • 2018
  • This study aims to find gender differences in inpatients' privacy and stress concerns in multi-bed hospital room. In the literature review, we consider the characteristics of multi-bed hospital room and patients' privacy as a psychological environment factor. In the survey research, the questionnaires were used to understand the inpatients' general characteristics and privacy requirements. A total of 109 copies were analyzed through a cross-tabulations and T-test using the SPSS 18.0. Results and conclusions are as follows: (1) In the case of multi-bed room patients, there were some gender differences in privacy and stress, but the differences were limited. (2) There is a difference in the patient 's preference of the hospital room according to gender, and this is related to the privacy characteristic. (3) The social communication and strolling are commonly effective stress relief methods for both men and women, so space is needed to do this methods. The meaning of this study is to specify the privacy and stress of the inpatients in multi-bed patients' room.

Development of the Insect Smart Farm System for Controlling the Environment of Protaetia brevitarsis seulensis

  • Rho, Si-Young;Won, Jin-Ho;Lee, Jae-Su;Baek, Jeong-Hyun;Lee, Hyun-Dong;Kwak, Kang-Su
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권12호
    • /
    • pp.135-141
    • /
    • 2019
  • 이 연구는 식품원료로 등록되고 건강기능성 효능이 널리 알려지면서 생산과 수요가 점차 증가하고 있는 흰점박이꽃무지 유충의 사육환경 제어를 위한 식용곤충 스마트팜 공조시스템을 설계하여 제안하고자 수행하였다. 제안된 곤충 스마트팜 공조 시스템은 사육실과 공조실을 구분하여 사육에 최적화된 환경을 공조실에서 만들어 사육실로 보급하는 시스템으로 기존 곤충 사육농가에서 냉난방기, 가습기 등을 통한 환경 제어를 할 때 사육실 내 부분별로 온도 및 습도 등이 매우 상이하여 식용곤충을 판매할 때 균일한 크기 및 무게의 흰점박이꽃무지 유충을 생산하기 어렵다는 문제점의 해결책으로 제시될 수 있다. 곤충 스마트팜 공조 시스템을 사용함으로써 기존 곤충농가의 환경제어에 비해 온도의 차를 6℃, 습도의 차를 24.7%를 감소할 수 있으며 사육실 내 부분별로 온·습도가 다른 점을 개선하여 흰점박이꽃무지 유충의 사육 최적 환경을 계절에 상관없이 상시 제공함으로써 연중 생산을 통한 생산량 증대와 곤충 사육농가의 소득증대를 도모할 수 있다. 또한 제안된 곤충스마트팜 공조시스템은 설정된 최적 온도, 습도 및 CO2를 효율적으로 제어함으로써 갈색거저리 등 기타 식용곤충의 사육 및 버섯류의 생육에 필요한 환경제어 시스템으로도 활용할 수 있을 것이다.

Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정 (Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe)

  • 김지민;한아영;이하영;이소라;권대철
    • 한국자기학회지
    • /
    • 제26권5호
    • /
    • pp.168-172
    • /
    • 2016
  • MRI 검사실의 최적환경을 목적으로 검사실 및 모니터의 휘도와 조도를 측정하였다. 대학병원(n = 6)의 MRI(n = 10)에서 휘도와 조도를 Unfors Xi Light Probe(Unfors Instruments AB, Billdal, Sweden)를 이용하여 측정하였다. 휘도는 black level과 white level을 조도는 모니터의 측면의 중앙에서 3회 반복하여 평균과 표준편차를 구하여 t-test를 이용하여 유의성 검정의 통계적 처리를 하였다. 모니터 휘도는 black level에서 평균 $1.78cd/m^2$, 표준편차 $0.85cd/m^2$이었고, white level에서는 평균 $43.58cd/m^2$, 표준편차 $13.19cd/m^2$로 측정되었다. MRI 검사실 조도는 최저값 30.5 lux, 최대값 601.3 lux, 평균 177.86 lux로 측정되었고, 휘도와 조도는 통계학적으로 유의한 차이가 있다(p < .05). MRI 모니터 및 검사실 휘도와 조도의 권고 기준을 참고하여 최적인 환경을 조성하도록 한다.

교육시설 친환경 인증에서 실내 빛환경 항목 개선방안에 관한 연구 - G-SEED, LEED, BREEAM, CASBEE를 중심으로 - (A Study on the Improvement Method of Indoor Light Environment Items in Environmental Certification for Educational Facilities - Focusing on G-SEED, LEED, BREEAM, CASBEE -)

  • 이세원;이경선;김수란
    • 대한건축학회논문집:계획계
    • /
    • 제34권5호
    • /
    • pp.61-69
    • /
    • 2018
  • The goal of this study is to compare the evaluation results of indoor daylight environment for each certification and propose improvement points. As the importance of indoor daylight environment has increased, foreign countries have been aware of this and have changed the light environmental certification items. On the other hand, Korea environmental certification systems have not been able to follow the current situation. In order to improve this, this study intended to find evaluation criteria for each category by comparing and analyzing indoor daylight environment certification items in Korea's G-SEED, LEED in the United States, BREEAM in the UK, and CASBEE in Japan. After that, this study simulated 3D models of three spaces about classroom, reading room and club room of Yanghyun elementary School which is scheduled to be constructed for the evaluation of indoor daylight environment, and the results were analyzed to suggest for improvement.

A Study on the Actual Condition of Illumination Environment in Public Libraries in Daegu

  • Seo, Ji-Eun;Kim, Hyun-Ji;Kim, Sung-Hwa;An, Ok-Hee
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2009
  • This study investigated the actual condition focusing on the lighting environment which is a major element in aspect of indoor environment of a public library and assessed user satisfaction. Research results are as follows: Firstly, numbers of lighting fixtures per dimension of a reading room in a public library were inconsistent due to the lack of definite regulations, which was found to have negative effect on night time illuminance. Secondly, it was assessed that illuminance between the day time influenced by natural lighting and in the nighttime without natural lighting has more than 10-fold difference. Therefore, such a condition is judged to be inappropriate for lighting environment of a reading room where users spend a long time studying and thus, it is considered that an appropriate measures should be taken. Thirdly, as the survey result on users' satisfaction with lighting environment was revealed to be lesser than 3 points, lighting plan in consideration of its users should be progressed.

종합병원 간호사의 부서별 사회심리적 업무환경이 직무만족에 미치는 영향 (Impacts of Psychosocial Work Environment on Nurses' Job Satisfaction Based on the Type of Hospital Departments)

  • 원효진
    • 보건의료산업학회지
    • /
    • 제12권1호
    • /
    • pp.47-56
    • /
    • 2018
  • Objectives : The purpose of this study was to compare the characteristics of nursing work environments based on department type and to investigate the relationship between work environment and job satisfaction. Methods : The participants were 420 nurses from the ward, emergency room, intensive care unit, and operation room. The data were analyzed by descriptive statistics, ANOVA, Scheffe's test, and multiple regression test using the SPSS Win. 18.0 program. Results : The results were as follows: There was a significant difference in possibilities for development, meaning of work, recognition(reward), role clarity, and social community at work based on department type. The factors that influenced job satisfaction were influence, meaning of work, recognition(reward), role conflicts, and quality of leadership and these differed based on department type. Conclusions : The results of this study indicate that nursing work environments vary based on the type of hospital department. Therefore, it is necessary to develop diverse strategies for human resource management considering the type of department.

대전지역 저소득층 주거환경의 질적인 개선에 관한 연구 (A Study on the Quality Improvement of Housing Environment in Low-Income Families of Daejeon Area)

  • 이정희
    • 대한가정학회지
    • /
    • 제28권2호
    • /
    • pp.57-72
    • /
    • 1990
  • The purpose of this study were ; (1) to analyze the relationship between actual housing condition and housing satisfaction with socio-demographic and housing characteristics of respondents and (2) to present the device on the quality of housing environment in low-income families. The sample was a proportional, stratified, random sample of 299 low-income families in Deajeon. The major findings were as follows: 1) The wholey, actual housing conditions were not good; especially the worst conditions appeared exterior walls, roof, kitchen, bath and toilet, heating, noise, recreation facilities as play-ground. 2) Actual housing condition has been found to be related to income, tenure(rent or own), persons/room. In the relation of the socio-demographic and housing characteristics, actual housing condition, housing satisfaction, income and persons/room were found to be a significant explanatory variable in actual housing condition. And actual housing condition ws appeared to be the strongest variable in housing satisfaction. 3) Housing of the low-income families should be improved physical aspects of the environment and be reflected in need of the occupant that based on the social-welfare housing concept.

  • PDF