• Title/Summary/Keyword: environment of pipe

Search Result 518, Processing Time 0.026 seconds

Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse (냉수파이프에 의한 온실의 제습 및 증발냉각효율)

  • 김문기;남상운;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.237-245
    • /
    • 1998
  • Greenhouse crop production under critical summer climate In Korea has considerable difficulties because of high temperature and relative humidity. In this study, some water pipes were tested as a means of the dehumidification and increment of evaporative cooling efficiency. As a result of heat transfer characteristic analysis, overall heat transfer coefficient of copper pipe was larger than steel pipe, and estimated values were smaller than measured values. The condensed quantities of vapor were not significantly different between copper pipe and steel pipe, however dehumidifying effect by the water pipes was significantly large. It was estimated based on the results that the evaporative cooling system by the water pipe will be able to increase the evaporative cooling efficiency of about 48%, and decrease the temperature of about 1.3$^{\circ}C$.

  • PDF

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

The development of a practical pipe auto-routing system in a shipbuilding CAD environment using network optimization

  • Kim, Shin-Hyung;Ruy, Won-Sun;Jang, Beom Seon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.3
    • /
    • pp.468-477
    • /
    • 2013
  • An automatic pipe routing system is proposed and implemented. Generally, the pipe routing design as a part of the shipbuilding process requires a considerable number of man hours due to the complexity which comes from physical and operational constraints and the crucial influence on outfitting construction productivity. Therefore, the automation of pipe routing design operations and processes has always been one of the most important goals for improvements in shipbuilding design. The proposed system is applied to a pipe routing design in the engine room space of a commercial ship. The effectiveness of this system is verified as a reasonable form of support for pipe routing design jobs. The automatic routing result of this system can serve as a good basis model in the initial stages of pipe routing design, allowing the designer to reduce their design lead time significantly. As a result, the design productivity overall can be improved with this automatic pipe routing system.

Manufacturing and Temperature Measurements of a Sodium Heat Pipe

  • Lee, Byeong-In;Lee, Seong-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1533-1540
    • /
    • 2001
  • A high-temperature sodium stainless steel heat pipe was fabricated and its performance has been investigated. The working fluid was sodium and it was sealed inside a straight tube container made of stainless steel. The amount of sodium occupied approximately 20% of the total volume of the heat pipe and its weight was 65.7gram. The length of a stainless steel container is 1002mm and its outside diameter is 25.4mm. Performance tests were carried out in a room air condition under a free convective environment and the measured temperatures are presented. The start-up behavior of the heat pipe from a frozen state was investigated for various heat input values between 600W and 1205W. In steady state, axial temperature distributions of a heat pipe were measured and its heat transfer rates were estimated in the range of vapor temperature from 50$0^{\circ}C$ to 63$0^{\circ}C$. It is found that there are small temperature differences in the vapor core along the axial direction of a sodium heat pipe for the high operating temperatures. But for the range of low operating temperatures there are large temperature drops along the vapor core region of a sodium heat pipe, because a small vapor pressure drop makes a large temperature drop. The transition temperature was reached more rapidly in the cases of high heat input rate for the sodium heat pipe.

  • PDF

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design (온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.204-211
    • /
    • 2019
  • The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to $16.3^{\circ}C$ and $14.6^{\circ}C$ during the experiment, respectively. The average water temperature in heating pipes was $52.3^{\circ}C$ and $45.0^{\circ}C$, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of $5.71{\sim}7.49W/m^2^{\circ}C$. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.

Corrosion Failure Analysis of Air Vents Installed at Heat Transport Pipe in District Heating System (지역난방수 공급관 에어벤트 부식 파손 분석)

  • Lee, Hyongjoon;Chae, Hobyung;Cho, Jeongmin;Kim, Woo Cheol;Jeong, Joon Cheol;Kim, Heesan;Kim, Jung-Gu;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.189-195
    • /
    • 2020
  • Two air vents situated on a heat transport pipe in district heating system were exposed to the same environment for 10 years. However, one air vent was more corroded than the other. It also had a hole on the top of the front-end pipe. Comparative analysis was performed for these air vents to identify the cause of corrosion and establish countermeasures. Through experimental observation of the damaged part and analyses of powders sampled from air vents, it was found that corrosion was initiated at the top of the front-end pipe. It then spread to the bottom. Energy dispersive X-ray spectroscopy results showed that potassium and chlorine were measured from the corroded product in the damaged air vent derived from rainwater and insulation, respectively. The temperature of the damaged air vent was maintained at 75 ~ 120 ℃ by heating water. Rainwater-soaked insulation around the front-end pipe had been hydrolyzed. Therefore, the damaged air vent was exposed to an environment in which corrosion under insulation could be facilitated. In addition, ion chromatography and inductively coupled plasma measurements indicated that the matrix of the damaged front-end pipe contained a higher manganese content which might have promoted corrosion under insulation.

A Study for Drainage Pipe Construction Method using a Boring Machine (천공장치를 이용한 배수설비 연결관 시공 기술에 관한 연구)

  • Chang, Jae-Goo;Kang, Seon-Hong;Kim, Dong-Eun;Jung, Tae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.869-875
    • /
    • 2011
  • Ministry of Environment has been promoting BTL business of the sewer rehabilitation which continues from 2005 up to now. Sewer rehabilitation is classified into three parts : wastewater pipe rehabilitation, rainwater pipe rehabilitation and drainage equipment rehabilitation. Drainage equipment rehabilitation is that drainage pipe connects wastewater pipe directly without water-purifier. In the drainage equipment construction, it is inevitable to have the damage of ground structures(wall, gate and U drain, etc) when an open excavation method is used. Therefore it is necessary to develop non-excavation method to connect drainage pipe and wastewater pipe like jacking method to avoid the damage of ground structure. This paper has conducted an analysis of the non-excavation method using a boring machine attached to backhoe, which is issued the verification certificate of environmental technology according to the Development of and Support for Environmental Technology Act, article.7. The index set in this analysis was sectionalized to the condition of construction, the grade of drainage pipe, the size of excavated hole, the amount of waste cement concrete and asphalt concrete and the benefit effect compared to open excavation method.

The Determination of Optimal Steel Pipe Wall Thickness Considering Ground Condition (지반 조건을 고려한 최적강관두께의 결정)

  • Park, Jaesung;Oh, Bungdong;Lee, Hojin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.11-15
    • /
    • 2008
  • By considering manufacture and economic factor, the steel pipes have been employed for water supply pipeline with large diameter. The standard to decide a thickness of pipe was provided by the waterworks standard (Ministry of Construction & Transportation, 1992) in South Korea. However, there was no the systematic standard to confirm a thickness of pipe in it. Thus, it should be able to apply to unsuitable the Stewart formula for the buried pipe to design for an optimum thickness of pipe. In order to meet revised the waterworks standard (The Ministry of Environment, 1997), it has been considered both the ground condition and all of the stresses to compute a thickness of pipe. As a results, a method is suggested to determine thickness of pipe after comparing and validating the obtained results with the established results from the Stewart formula.

  • PDF

A Study of the Surface Temperature Reduction Using Pipe Cooling System in Asphalt Pavement (아스팔트 도로포장에 물순환 파이프 시스템을 이용한 표면온도저감에 관한 연구)

  • Yoon, Yong Kyu;Park, Kyung Won;Lee, Suk Keun
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.75-86
    • /
    • 2013
  • PURPOSES: The purpose of asphalt pavement reducing surface temperature by using Pipe cooling system is to make pleasant city life environment. METHODS: We considered building condition to lay the pipes under asphalt pavement and figured out that temperature reducing effect with pipe cooling system. In addition, we guessed rutting through wheel tracking test with a laid the pipes under asphalt mixture and performed fatigue cracking through a flexural fatigue test for performance evaluation of pipe cooling system. RESULTS: When pipe cooling system worked, the temperature of pavement model reduced quickly in test. The system can turn down the degree by 4 or 5 quickly as well. It didn't affect rutting to lay the pipes under the pavement, but it can get damaged to asphalt pavement in early stage by the result of performance evaluation. CONCLUSIONS: We figured out that pipe cooling system can turn down the temperature of aspalt pavement surface through tests. We suggest that pipe cooling system should be considered one of the effective way to solve urban heat island problem.