• Title/Summary/Keyword: environment of pipe

Search Result 518, Processing Time 0.031 seconds

Estimation of Characteristic of the Soil Physical using the Pipe Type Soil Sampler (원관형 토양샘플러를 이용한 토양물리특성 추정)

  • Ryu, Ji Hyun;Jung, Myung Kwan;Park, Seung Ki
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.95-104
    • /
    • 2020
  • The purpose of this study is to develop a pipe type soil sampler that can easily collect soil cross section servey and soil samples to conduct ecological environment surveys while minimizing ecological disturbance in the area subject to soil survey. Furthermore, this study develop the exponential type estimation specific weight formula (ESWF) that uses pipe type soil sampler to easily carry out soil cross section survey and soil sample while estimating the specific weight of the area using water content and soil sample length variation ratio (SLVRs) and to obtain apparent specific gravity, hardness, and max. porosity which are used as growth of corps and ecological environment index. The calibration results of ESWF showed a high degree of significance, with NSE for actual specific weight (γ0) and calibration estimation specific weight (γec) 0.95, R2 for 0.954, and RMSE for 0.051. The verification results of ESWF showed a high significance, with NSE for actual specific weight (γ0) and verification estimation specific weight (γev) 0.881, R2 for 0.978, and RMSE for 0.055.

Analyses of Actual State and Structural Safety of Regionally Characterized Greenhouses in Korea (지역별 특성화 온실의 실태 및 구조적 안전성)

  • 김문기;남상운;손정익;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.3 no.2
    • /
    • pp.128-135
    • /
    • 1994
  • Recently, regionally characterized greenhouses have been built every place around the country. These greenhouses insist of their higher performance by considering regional merits than the greenhouses without considering regional ones, but it is not clear. The purpose of this study was to make clear the characteristics of the regionally characterized greenhouses through the analyses of actual state and structural safety. The greenhouses were investigated and classified into wide span house, large pipe house, arched lattice house, wooden house, viniculture house, and domed pipe house. The frames of wide span house, arched truss house, viniculture house and domed pipe house were analyzed to be structurally stable under the design wind speeds and snow depths in recurrence intervals of 15 or 30 years, but large pipe house was a little unstable and required some reinforcements, and wooden house turned out to be unstable. In addition, foundations of all characterized greenhouses were stable against pull - out capacity under the design wind speeds in recurrence interval of 30 years.

  • PDF

Development and Measurement Error Compensation of Odometer System for Intelligent PIG (인텔리전트 피그를 위한 주행거리계의 개발 및 측정오차 보상)

  • Kim D.K.;Park S.S,;Cho S.H.;Yoo H.R.;Park D.J.;Koo S.J.;Rho Y.W.;Kho Y.T
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.17-23
    • /
    • 2002
  • This paper introduces the spring-mounted odometer system which maintains the correct contact with the pipe wall and measures the distance along the pipe. The odometer wheel is designed to keep contact to the pipelines inner wall and to generate fifty rectangular pulses per one turn(159.5681mm) during pigging. The pipeline has the defects in various types such as buckles, winkles, cracks, dents, welding point and so on. Specially girth welding points which exist each 12m of the pipeline, much affects the operational environment of the odometer. The measurement error of the distance along the pipe is accumulated, for the measurement error of wheel's circumference and the pipeline inner environment. So, this paper proposes the method for the error compensation based on the analysis of the odometer's behavior around the girth welding point of pipe. The experimental results show that developed odometer system can be used for the intelligent pig with good performances.

  • PDF

Comparative Study on Water Hammer for Pump Station in High Pressurized Pipes in Kuwait

  • Shim, Kyu Dae;Kang, Yong Suk;Choung, Joon Yeon;Abdellatif, Mohamed;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.265-269
    • /
    • 2017
  • Because of abrupt changes for velocity in water, transient flow is occurred in practical life. To reduce and avoid the high or low pressure of pipe network system, various surge protection facilities are used to prevent the risk in pipe network system. Especially, we focused on study not only preventing positive and negative pressure but also selecting adequate equipment for high pressurized pipelines. Several critical cases were considered by undertaking a steady state hydraulic study and transient dynamic simulation and we suggested that the surge vessel of various surge protection system was recommended to control high and low pressures on pipeline system in perspective.

  • PDF

Screw-Propelled Robot for Detecting Grease Pipe (그리스 충전 덕트 내 탐상을 위한 스크류 추진 로봇)

  • Kim, HoJoong;Kim, Dongseon;Kim, Jinhyun
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.2
    • /
    • pp.178-182
    • /
    • 2022
  • Post-tension duct in nuclear reactor containment building is filled with grease to prevent steel strand from corroding. If grease leaks by break of duct, steel strand will corrode and cause problem in building safety. Therefore, grease leak should be checked preventatively. But currently used method is inefficient, since it has to remove grease and strand to check. And other methods for checking post-tension dust are not well-researched. In this paper, we develop screw-propelled robot that can move in grease and detect grease duct directly. Also, we make the test environment that is similar to real post-tension duct of containment building and test robot in that environment to verify that our robot is feasible in the post-tension duct. The robot can move forward and backward in grease duct by twin screw mechanism and has mount for sensors to detect grease leakage and strand corrosion.

The Research and Application of Protective Coating for PCCP

  • Lin, Zhu;Xu, Cuizhu;Zhang, Li;Fan, Yunpeng;Zhang, Qibin
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.265-268
    • /
    • 2008
  • Prestressed Concrete Cylinder Pipe(PCCP) had became one of the dominating kinds of pipes substituting for steel pipes because of its unique feature (high intensity, high pressure and high leakproofness). PCCP was produced firstly by Bonna company in France. By the end of 20th century, there were over 19000 km of this product installed in America. PCCP was introduced from Ameron company by Shandong Eletric Power Pipeline Engineering Company in 1988. As the statistical data in 2002, 700 km of PCCP had been applied in China, and the application trended towards rapid increase.Since prestressing wire would be corroded in environment, Several accidents due to the breakdown of pipe had happened. Consequently the external wall of pipe should be covered with protective coatings. There was a lack of technical study in corrosion and control of PCCP, because PCCP had been applied for a short time in China. in order to ensure the service life of PCCP, we have developed a kind of protective coating for concrete pipe, which had high intensity and anti-corrosive property with convenient applicability. The physical and chemical properties, painting technology and field application of this coating was introduced in the paper, at the same time, the future of external protective coating for PCCP was looked into.

Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations (파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가)

  • Lee, Seokjae;Oh, Kwanggeun;Han, Shin-in;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

Development of Eco-friendly Basalt Fiber-reinforced Furan-based Composite Material with Improved Fire and Flame Retardants for Shipbuilding and Offshore Pipe Insulation Cover (조선해양 파이프 단열재 커버 적용을 위한 내화/난연 성능을 갖는 친환경 바잘트섬유 강화 퓨란계 복합재료 개발 연구)

  • Kwon, Dong-Jun;Seo, Hyoung-Seock
    • Composites Research
    • /
    • v.34 no.1
    • /
    • pp.57-62
    • /
    • 2021
  • As interest in the eco-friendly ships and lightweight equipment is increasing in the shipbuilding and marine industry, composite materials are applied to equipment such as pipes. In this study, a basalt fiber reinforced furan composite (BFC), an eco-friendly material, was manufactured to apply the pipe insulation cover that requires environment-friendly and heat/flame retardant performance. An optimization study of post-curing conditions of BFC was conducted, and experiments and analysis were performed on mechanical strength, heat/flame retardant properties, and affinity properties. Finally, as a result of the study BFC material is proved to be a good candidate to apply pipe insulation cover.

Prediction of the Scour Depth around the Pipeline Exposed to Waves using Neural Networks (신경망을 이용한 파랑하 관로주변의 세굴심 예측)

  • Kim, Kyoungho;Cho, Junyoung;Lee, Hojin;Oh, Hyunsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.5
    • /
    • pp.15-22
    • /
    • 2013
  • The submarine pipe, which is one of the most important coastal structures, is widely used in the development of coastal and ocean engineering. The scour of the submarine pipe occurs due to the wave and the current according to the state of the sea bed. The scour affects the submarine pipe and causes it to undergo settlement and fatigue. It is difficult to predict the local scour under complicated and various conditions of the coastal environment, even though many researches on the scour of the submarine pipe have been studied in recent years. This study analyzed the scour depth around a submarine pipe by using the Neural Network technique. The back-propagation algorithms was used to train the Neural Network. The 58 simulating experimental data for the performance and validation of the Neural Network technique were analyzed in this study. Then, the regression analysis for the same data was performed in this study to predict and compare with the Neural Network technique for the scour depth.

Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device (아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구)

  • Yum, Kyung-Taek;Choi, Jung-Wook;Yang, Sung-Bong;Shim, Hak-Sup;Yu, Mee-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.