Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권12호
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

고선량율 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교 ${\cdot}$ 연구

  • 허현도;박성용;이레나;신동오;권수일;노준규;최진호
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.78-80
    • /
    • 2004
  • 본 연구에서는 쐐기형태의 선량분포를 구현할 수 있도록 고안된 미국 Varian사 동적쐐기(EDW ; Enhanced Dynamic Wedge)의 표면선량(surface dose)과 주변선량(peripheral dose) 특성을 분석하였다. 쐐기각도 15${\circ}$, 30${\circ}$, 45${\circ}$, 50${\circ}$를 대상으로 금속쐐기를 사용했을 경우와 동적쐐기를 사용했을 경우에 대해 해당 선량특성을 비교, 분석하였다. 표면선량 측정 결과, 동적쐐기가 금속쐐기보다 더 높은 선량 분포를 보였으며, 주변선량의 경우, 금속쐐기가 동적쐐기보다 더 높은 선량분포를 보였다. 이는 금속쐐기의 빔 필터링에 의한 빔 경화(hardening) 현상과 광자선과의 산란 현상에 기인한 결과로 방사선치료 계획 시 동적쐐기의 적용에 있어 고려해야 할 주요 특성이라 사료된다.

  • PDF

고속선의 트림제어 장치가 항주 자세 및 저항 성능에 미치는 영향 (Experimental investigation of dynamic trim control devices in fast speed vessel)

  • 서광철
    • 한국항해항만학회지
    • /
    • 제37권2호
    • /
    • pp.137-142
    • /
    • 2013
  • The displacement Deep-V catamaran concept was developed in Newcastle University(UNEW) through development of the systematic Deep-V catamaran series. One of the most important Deep-V catamaran launched to date is Newcastle University's own multi-purpose research vessel, The Princess Royal. The vessel was launched in 2011 and enhanced the Deep-V catamaran concept further with the successful adoption of a novel anti-slamming bulbous bow and tunnel stern for improved efficiency. It was however identified that the vessel has substantial amount of dynamic trim that limited the visibility of the captain. The dynamic trim also increased the wave-making resistance thereby preventing the vessel from attaining its maximum speed in certain sea states. This paper therefore presents the application of devices such as Trim Tabs, Interceptors, Transom Wedges and Integrated Transom Wedges-Tabs to control the dynamic trim and improvement of fuel efficiency of the vessel. All of these energy saving devices were fitted into a model for tests in Newcastle University's Towing Tank. Model test verification confirmed that the optimum appendage was the interceptors, they produced a 5% power saving and 1.2 degree trim reduction at 15 knots, and investigations of full scale trials will be scheduled with and without application of device to compare the improvement of performance.

보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가 (Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery)

  • 박병문;방동완;배용기;이정우;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.401-406
    • /
    • 2008
  • 목적 : 종속조사면 병합 치료방법(FIF : Field In Field)을 이용한 유방절선조사 시 반대편 유방의 표면선량을 평가하고자 한다. 대상 및 방법 : FIF치료방법 이용 시 반대편 유방에 흡수되는 표면선량을 평가하고자 동일한 기하학적 조건과 처방선량을 기반으로 열린조사면(Open), 금속쐐기(MW : Metal Wedge), 동적쐐기(EDW : Enhanced Dynamic Wedge)를 이용한 조사방법과 비교하였다. 3차원 치료계획장치를 이용하여 선량분포 최적화를 수행하였으며 계산 결과의 정확도를 검증하기 위해 인체 팬톰과 모스펫 측정기를 사용하여 측정을 수행하였다. 동측 유방 입사면 가장자리로부터 반대편 유방 쪽으로 2, 4, 6, 8, 10cm 지점을 선정하여 각각 표면(0cm : 가피)과 0.5cm(진피) 깊이에서 선량을 측정하였으며, 0.5cm 깊이 선량측정을 위해서 0.5cm 볼루스를 사용하였다. 선량분포의 계산은 불균질 물질을 보정(modified Batho method)하여 0.25cm 격자 해상도로 수행하였다. 결과 : 치료계획장치에서 각 지점의 평균표면선량은 금속쐐기의 경우 표면 및 0.5cm 깊이에서 $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ 증가했고, 동적쐐기는 $1.0{\sim}7.9%$, $1.6{\sim}37.4%$까지 증가하였다. FIF는 $-18.4{\sim}0.7%$, $-8.1{\sim}4.7%$까지 선량이 변화하였다. MOSFET을 이용하여 측정한 경우는 금속쐐기는 표면 및 0.5cm 깊이의 경우 $11.1{\sim}71%$, $22.9{\sim}161.2%$ 증가했고, 동적쐐기는 $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ 선량이 증가했다. FIF는 표면에서 $-15.7{\sim}-4.9%$로 선량이 오히려 감소했으며, 0.5cm 깊이에서의 선량도 $-10.5{\sim}3.6%$로 나타났다. 치료계획장치의 계산값과 실측값을 비교한 결과, 유사한 경향을 보였으나 치료계획장치의 경우 피부선량이 실제측정값보다 다소 과소평가되고 있음을 알 수 있었다. 결론 : 본 실험을 통해 FIF치료방법의 경우 기존 치료방법(MW, EDW)에 비해 치료표적에 최적화 된 선량 분포를 만들어 내면서도 반대편 유방의 피부에 불필요한 산란선량을 최소화하는 치료방법임을 알 수 있었다.

  • PDF

Clinical and Radiological Features of Diffuse Lacrimal Gland Enlargement: Comparisons among Various Etiologies in 91 Biopsy-Confirmed Patients

  • Sae Rom Chung;Gye Jung Kim;Young Jun Choi;Kyung-Ja Cho;Chong Hyun Suh;Soo Chin Kim;Jung Hwan Baek;Jeong Hyun Lee;Min Kyu Yang;Ho-Seok Sa
    • Korean Journal of Radiology
    • /
    • 제23권10호
    • /
    • pp.976-985
    • /
    • 2022
  • Objective: To compare the clinical and radiological features of various etiologies of chronic diffuse lacrimal gland enlargement. Materials and Methods: We retrospectively reviewed 91 consecutive patients who underwent surgical biopsy for chronic diffuse lacrimal gland enlargement and were diagnosed with non-specific dacryoadenitis (DA) (n = 42), immunoglobulin G4-related dacryoadenitis (IgG4-RD) (n = 33), and lymphoma (n = 16). Data on patient demographics, clinical presentation, and CT imaging findings (n = 73) and MRI (n = 43) were collected. The following radiologic features of lacrimal gland enlargement were evaluated: size, unilaterality, wedge sign, angle with the orbital wall, heterogeneity, signal intensity, degree of enhancement, patterns of dynamic contrast-enhanced, and apparent diffusion coefficient value. Radiological features outside the lacrimal glands, such as extra-lacrimal orbital involvement and extra-orbital head and neck involvement, were also evaluated. The clinical and radiological findings were compared among the three diseases. Results: Compared to the DA and IgG4-RD groups, the lymphoma group was significantly older (mean 59.9 vs. 46.0 and 49.4 years, respectively; p = 0.001) and had a higher frequency of unilateral involvement (62.5% vs. 31.0% and 15.2%, respectively; p = 0.004). Compared to the IgG4-RD and lymphoma groups, the DA group had significantly smaller lacrimal glands (2.3 vs. 2.8 and 3.3 cm, respectively; p < 0.001) and a lower proportion of cases with a wedge sign (54.8% vs. 84.8% and 87.5%, respectively; p = 0.005). The IgG4-RD group showed more frequent involvement of the extra-orbital head and neck structures, including the infraorbital nerve (36.4%), paranasal sinus (72.7%), and salivary gland (58.6%) compared to the DA and lymphoma groups (4.8%-28.6%) (all p < 0.005). Conclusion: Patient age, unilaterality, lacrimal gland size, wedge sign, and extra-orbital head and neck involvement differed significantly different between lymphoma, DA, and IgG4-RD. Our results will be useful for the differential diagnosis and proper management of chronic lacrimal gland enlargement.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • 홍동기;이우석;권경태;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.43-61
    • /
    • 2004
  • 목적 : 환자의 치료에 있어서 정확한 장비의 설치와 성능 평가는 치료의 질을 향상시키는데 중요한 요소라고 할 수 있으며 사용자가 장비의 특성과 사용 방법을 숙달하고 업무를 수행하는 것이 매우 중요하다고 생각한다. 그러므로 방사선 치료기를 설치하고 방사선 치료를 하기 전에 사용자가 직접 장비의 설치와 성능 평가에 참여하고 특성을 파악하여 이해하는 것이 필요하다. 본 연구에서는 CAP의 과정과 성능 평가결과를 소개하고자 한다. 대상 및 방법 : 선형가속기 21EX(varian, USA)를 대상으로 설치 시부터 성능 검사까지 전 과정을 평가하였고 성능평가는 크게 radiation survey, mechanical test, radiation isocenter test, beam performance, dosimetry, enhanced dynamic wedge로 구분하여 X-omat film(kodark), 선량 측정 장비(multidata, densitometer, electrometa)를 이용하여 실시하였다. 또한 선형가속기에 부착된 MLC(millenium, 120leaf)와 EPID(portal vision)의 성능 평가는 별도로 실시하였다. 결과 : Survey meter를 이용하여 측정한 leakage는 허용 범위 이하의 선량이 검출되었고 mechanical test에서 collimator, gantey, couch rotation은 1mm 이하였고 육안으로 평가한 angle은 digital이 ${\pm}1^{\circ}$이내에 mechanical은 ${\pm}5^{\circ}$이내였다. 또한 light field와 cross-hair의 직선성 검사도 1mm이내로 평가되었다. (A)symmetrical jaw field는 upper/lower 모두 ${\pm}0.5mm$이내였다. X-omat film을 이용한 radiation isocenter test는 1mm 이하였고 light field와 radiation field 의 일치성 검사는 ${\pm}1mm$ 이내였으며 선량 측정 장비를 이용하여 측정한 $\%DD$는 photon energy는 모두 ${\pm}1\%$ 이내로 electron energy는 $90\%,\;80\%,\;50\%,\;30\%$를 측정한 결과 허용 범위 내에서 평가되었다. photon 과 electron energy의 flateness는 각각 $2.3\%$(기준 $3\%$)이내, $3\%$(기준 $4.5\%$)이내이고 symmetry는 $0.45\%$(기준 $2\%$), $0.3\%$(기준 $2\%$)이내에서 평가 할 수 있었다. 그리고 dosimetry test는 sort term, MU setting, rep rate, dose rate accuracy를 photon과 electron energy 별로 MU와 gantry angle을 바꿔가면서 측정한 결과 허용범위 오차이내에 포함되는 것을 확인 할 수 있었다. EPID(portal vision)의 Exact-Arm의 기계적인 검사는 vertical, lateral, longitudinal은 허용범위 내에서 동작했으며 명암과 해상도 검사도 05.mm의 니크롬선이 선명하게 나타났으며 phantom의 음영도 뚜렷하게 나타났다. Multileaf collimator(MLC)검사는 leaf이 isocenter의 중심에 정확하게 배열되었으며 재현성 검사도 정상적으로 동작하였다. 결론 : Clinac 21EX 장치의 customer acceptance를 통해서 향후의 환자의 치료를 하는데 있어 장치의 안정성을 확인 할 수 있었으며 치료 전의 선형가속기와 주변장치의 특성을 파악 할 수 있어서 장비 사용에 있어서 어려움을 감소시킬 수 있으리라고 생각된다. 또한 사용자가 적극적으로 참여함으로써 앞으로 환자를 치료하는데 있어서도 많은 도움이 되리라 생각한다.

  • PDF

세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석 (Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance)

  • 이정우;홍세미;김연래;최경식;정진범;이두현;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.131-135
    • /
    • 2006
  • 본 연구의 목적은 2차원적 이온전리함 배열의 특성을 분석하고 세기변조방사선치료 선량분포 확인의 유용성을 평가하기 위함이다. 본 실험에 사용된 2차원적 이온전리함 배열(MatriXX, Scanditronix-Wellhofer, IBA, Germany)은 $24{\times}24cm^2$ 범위에 1,024개의 평판형 전리함(용적: $0.08cm^3$, 직경: 4.5 mm, 높이: 5 mm, 배열간격: 7.62 mm)이 일정한 간격으로 배열되어있다. MatriXX의 특성분석을 위해 선량 직선성, 선량률 의존도, 출력 계수, 단기 선릉재현성을 분석하였으며, 선량분포 확인의 신뢰도를 평가하기 위해 Varian사의 동적쐐기와 세기변조 방사선치료의 선량분포를 분석하였다. 선량 직선성의 범위는 $1{\sim}800$cGy이었으며, 1% 미만의 오차율을 보였다. 선량률 의존성(범위 $100{\sim}600MU/min$)은 300 Mu/min을 기준으로 했을 때 모든 선량률 범위에서 0.4% 미만의 선량변화를 보였다. 또한, 물팬톰에서 0.1 cc 지두형 전리함으로 측정한 출력계수와 폴리스틸렌 팬톰에서 MatriXX로 측정한 출력계수를 비교하였다. 이 실험의 결과, $3{\times}3{\sim}24{\times}24cm^2$ 범위에서 0.5% 미만의 일치를 나타내었다. 단기 출력재현성 확인을 위하여 15분 간격으로 6회 측정한 결과, 0.5% 내의 차이를 보였다. 동적쐐기와 세기변조 방사선 조사면의 일치성 실험에서도 치료계획장치의 계산값과 필름측정값이 비교적 잘 일치함을 알 수 있었다. 본 연구를 통해 MatriXX의 물리적인 특성을 분석하였으며 세기변조방사선치료의 품질관리를 위한 유용성을 확인하였다.

  • PDF