• 제목/요약/키워드: energy-transfer

검색결과 4,157건 처리시간 0.037초

태양열 발전에서 태양열에너지 수송을 위한 고온 축열 물질의 열절달 특성 (Heat Transfer Characteristics of High Temperature molten salt storage for Solar Thermal Power Generation)

  • ;김기만;강용혁;한귀영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.190-193
    • /
    • 2008
  • The heat transfer characteristics of molten salt storage system for the solar thermal power generation were investigated. Temperature profiles and the heat transfer coefficients during the storage and discharge stage were obtained with the steam as the heat transfer fluid. Two kinds of inorganic salt were employed as the storage materials and coil type of heat exchanger were installed in both tanks to provide the heat transfer surfaces during the storage and discharge stage. The effects of steam flow rates, flow direction of steam in the storage tank and the initial temperature of storage and discharge tank on the heat transfer were tested.

  • PDF

Sea surface temperature estimation from remote measurement of the thermal radiation

  • Mima, Kazuhiko;Satoh, Makoto;Moriyama, Masao;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.12-15
    • /
    • 1994
  • To establish the sea surface temperature estimation scheme for the upcoming advanced remote sensor, the quasi-analytical solution of the approximated radiative transfer equation which express the radiative transfer process of the radiant energy radiated from the sea surface to the satellite is approximated into the non-linear equation. To solve the simultaneous approximated radiative transfer equation which express the radiative transfer process of the radiant energy radiated from the sea surface to the satellite is approximated into the nonlinear equation. To solve the simultaneous approximated radiative transfer equation at each channel, the constrained non-linear optimization technique is adopted. To define the coefficients of the approximated radiative transfer equation and the constraints, the satellite detected radiance and the total transmittance are computed from the 1350 kinds of simulated atmosphere / surface models via radiative transfer code. The verification from the simulated data show the sufficient result.

  • PDF

원형 실린더 후류 영역의 국소 열전달 특성 (Local Heat Transfer Characteristics in the Wake Region of a Circular Cylinder)

  • 장병훈
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.30-36
    • /
    • 2005
  • 본 논문에서는 실린더 후류 영역의 열전달 특성에 대한 실험결과를 보고하였다. 정체점(θ=0°)로부터 실린더 뒷면(θ=180°)까지 국소 열전달을 측정하였으며, 축 방향에 대한 누셀트 수의 변화도 조사하였다. 덕트 중앙에 비하여 덕트 벽면근처의 후류영역 열전달계수는 58% 정도 높게 측정되었으며, 종횡비와 열전달 경계조건의 영향도 조사하였다.

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.

Ground-Coupled 바닥구조체의 열전달 모델링 (An Approach to Model Ground-Coupled Building Foundation for Energy Simulation)

  • 임병찬
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.658-666
    • /
    • 2004
  • In this paper, a two-dimensional transient ground-coupled numerical model for slab-on-grade foundation is developed and integrated into EnergyPlus. A validation analysis is first presented to ensure that for the developed building foundation heat transfer module is properly implemented within EnergyPlus. Then, the predictions from the developed model are compared to those obtained from the simplified building foundation model currently used in EnergyPlus. The results show that the developed foundation heat transfer module accounts better for the effects of the ground thermal mass attributed to the ground than the simplified foundation model currently used in EnergyPlus.

Study on the Natural Convection Heat Transfer Characteristics in the Air Duct

  • Kim, Y.K.;Lee, Y.B.;Park, S.K.;J.S. Hwang;H.Y. Nam
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.451-456
    • /
    • 1997
  • Temperature distribution measurements in the mockup apparatus of reactor vessel were performed to determine the effective thermal conductivity of porous media with different geometry and to obtain the experimental data for the heat transfer processes by natural convection occurring in the air duct. The temperature distributions at four separated sections with different arrangements of porous media have different slopes according to the geometrical configuration. From the measured temperature distribution, effective thermal conductivity have been derived using the least square fitting method. The test at air duct was performed to the high heat removal at 3.4kW/$m^2$ by the natural convection from the outer wall to the air. And also the temperature distributions in the air duct agree well with the 1/7th power-law turbulent temperature distribution. The obtained heat transfer data have been compared with the Shin's and Sieger's correlations.

  • PDF

Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구 (A Study on Optimizing Energy Transfer of Capacitive Switching Antenna)

  • 김진만;방정주;허창수
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

원격 에너지 저장소를 가진 이동 센서 네트워크를 위한 에너지 수확 체계 (Energy Harvesting Framework for Mobile Sensor Networks with Remote Energy Stations)

  • 김성우;이종민;권순각
    • 제어로봇시스템학회논문지
    • /
    • 제15권12호
    • /
    • pp.1184-1191
    • /
    • 2009
  • Energy harvesting from environment can make the energy constrained systems such as sensor networks to sustain their lifetimes. However, environmental energy is highly variable with time, location, and other factors. Unlike the existing solutions, we solved this problem by allowing the sensor nodes with mobilizer to move in search of energy and recharge from remote energy station. In this paper we present and analyze a new harvesting aware framework for mobile sensor networks with remote energy station. The framework consists of energy model, motion control system and data transfer protocol. Among them, the objective of our data transfer protocol is to route a data packet geographically towards the target region and at the same time balance the residual energy and the link connectivity on nodes with energy harvesting. Our results along with simulation can be used for further studies and provide certain guideline for realistic development of such systems.

Collision-induced Energy Transfer and Bond Dissociation in Toluene by H2/D2

  • Ree, Jongbaik;Kim, Yoo Hang;Shin, Hyung Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3641-3648
    • /
    • 2013
  • Energy transfer and bond dissociation of $C-H_{methyl}$ and $C-H_{ring}$ in excited toluene in the collision with $H_2$ and $D_2$ have been studied by use of classical trajectory procedures at 300 K. Energy lost by the vibrationally excited toluene to the ground-state $H_2/D_2$ is not large, but the amount increases with increasing vibrational excitation from 5000 and $40,000cm^{-1}$. The principal energy transfer pathway is vibration to translation (V-T) in both systems. The vibration to vibration (V-V) step is important in toluene + $D_2$, but plays a minor role in toluene + $H_2$. When the incident molecule is also vibrationally excited, toluene loses energy to $D_2$, whereas it gains energy from $H_2$ instead. The overall extent of energy loss is greater in toluene + $D_2$ than that in toluene + $H_2$. The different efficiency of the energy transfer pathways in two collisions is mainly due to the near-resonant condition between $D_2$ and C-H vibrations. Collision-induced dissociation of $C-H_{methyl}$ and $C-H_{ring}$ bonds occurs when highly excited toluene ($55,000-70,400cm^{-1}$) interacts with the ground-state $H_2/D_2$. Dissociation probabilities are low ($10^{-5}{\sim}10^{-2}$) but increase exponentially with rising vibrational excitation. Intramolecular energy flow between the excited C-H bonds occurring on a subpicosecond timescale is responsible for the bond dissociation.

PREDICTION OF A HEAT TRANSFER TO CO2 FLOWING IN AN UPWARD PATH AT A SUPERCRITICAL PRESSURE

  • Cho, Bong-Hyun;Kim, Young-In;Bae, Yoon-Yeong
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.907-920
    • /
    • 2009
  • This study was performed to evaluate the prediction capability of a commercial CFD code and to investigate the effects of different geometries such as a 4.4 mm tube and an 8/10 mm annular channel on the detailed flow structures. A numerical simulation was performed for the conditions, at which the experimental data was produced by the test facility SPHINX. A 2-dimensional axisymmetric steady flow was assumed for computational simplicity. The RNG $\kappa-\varepsilon$ turbulence model (RNG) with an enhanced wall treatment option, SST $\kappa-\omega$ (SST) and low Reynolds Abid turbulence model (ABD) were employed and the numerical predictions were compared with the experimental data generated from the experiment. The effects of the geometry on heat transfer were investigated. The flow and temperature fields were also examined in order to investigate the mechanism of heat transfer near the wall. The local heat transfer coefficient predicted by the RNG model is very close to the measurement result for the tube. In contrast, the local heat transfer coefficient predicted by the SST and ABD models is closer to the measurement for the annular channel.