• Title/Summary/Keyword: energy window

Search Result 688, Processing Time 0.026 seconds

A Study on the Establish Environmental Impact of Database of the Envelope System for Green Remodeling of Apartment Housing (공동주택의 그린 리모델링을 위한 외피시스템 환경영향 DB 구축에 관한 연구)

  • Lee, Jong Geon;Tae, Sung Ho;Chae, Chang-U;Kim, Rak Hyun
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.73-79
    • /
    • 2016
  • Purpose: In order to improve the energy performance of existing buildings, so actively promoted green remodeling business. Also, improvement of the performance of envelope system of apartment housing is an absolute. The purpose of implementation of the data base and application plan of the envelope system for green remodeling of apartment housing. Method: For this study, It proposed a classification system of green remodeling envelope system constructed actual to select the applicable representative method and input material of apartment housing for green remodeling. In this study, divided into construction waste processing stage and production phase of the material for the boundary of the system, and implementation the classification system of the envelope system for applicable green remodeling. For this, established 6 environmental impact categories database. Result: As a result of various suggestions were available for case study research, alternative combinations of existing combinations than six kinds of environmental impact insulation system with superior input materials combining 96 kinds, window system, 12 kinds for determining the applicability of the established database. Depending on the account for a large proportion if compared to the detailed analysis of the environmental impact resulting from the production phase and disposal phase was analyzed that the operating management of the necessary input materials. Is considered that the economic performance and integrated energy performance required by the applicable public housing green remodeling evaluation techniques considered for future improvements insulation sheath.

Effects of Explosion on Structures (폭발이 구조물에 미치는 영향)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.37 no.4
    • /
    • pp.10-16
    • /
    • 2019
  • Information on overpressure, positive phase duration, and impulse are required to assess the effects of shock waves or pressure waves on the structure. In this study, the overpressure and positive phase duration were determined by applying the Multi-Energy Method, which is found to be effective in analyzing the explosion of vapor clouds. Based on the total heat of combustion estimated in the cyclohexane vapor cloud explosion in the Nypro Ltd(UK), overpressure and positive phase duration at the distance of 40, 80, 120, 160, 200, 240, 280, 320, 360(m) from the source of explosion were evaluated. Overpressure was shown to decrease exponentially and positive phase duration increased almost linearly with distance. A probit function was used to assess the probability of damages for the structures at each distance using the overpressure and impact obtained at the above mentioned distances. The Analyses of probability of damages have shown that there is a high probability of collapse at distances within 120m, major damage to structures within 240m, and minor damage and breakage of window panes of structures occur over the entire distances.

Comparing Solar Heat Shading Performances of Internal Blinds in the Summer (내측 블라인드의 하절기 일사열 차폐 성능 비교)

  • Park, Eun-Mi;Choi, Dong-Ho;Park, Min-Yong;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

Design and Preliminary Performance Test for 5kWt Dish Solar Collector ($5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Han, Gui-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex (공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.

An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer (이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구)

  • Kim, Dong-Kyun;Yoon, Kap-Chun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

Electrical Characteristics of Charge Trap Flash Memory with a Composition Modulated (ZrO2)x(Al2O3)1-x Film

  • Tang, Zhenjie;Zhang, Jing;Jiang, Yunhong;Wang, Guixia;Li, Rong;Zhu, Xinhua
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.3
    • /
    • pp.130-134
    • /
    • 2015
  • This research proposes the use of a composition modulated (ZrO2)x(Al2O3)1-x film as a charge trapping layer for charge trap flash memory; this is possible when the Zr (Al) atomic percent is controlled to form a variable bandgap as identified by the valence band offsets and electron energy loss spectrum measurements. Compared to memory devices with uniform compositional (ZrO2)0.1(Al2O3)0.9 or a (ZrO2)0.92(Al2O3)0.08 trapping layer, the memory device using the composition modulated (ZrO2)x(Al2O3)1-x as the charge trapping layer exhibits a larger memory window (6.0 V) at the gate sweeping voltage of ±8 V, improved data retention, and significantly faster program/erase speed. Improvements of the memory characteristics are attributed to the special energy band alignments resulting from non-uniform distribution of elemental composition. These results indicate that the composition modulated (ZrO2)x(Al2O3)1-x film is a promising candidate for future nonvolatile memory device applications.

The Selective Oxidation of CO in Hydrogen Rich Stream over Alumina Supported Cu-Ce Catalyst (알루미나에 담지된 Cu-Ce 촉매상에서의 개질수소가스에 포함된 CO의 선택적 산화 반응에 관한 연구)

  • Park, J.W.;Jeong, J.H.;Yoon, W.R.;Lee, Y.W.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.2
    • /
    • pp.155-170
    • /
    • 2003
  • $Cu-Ce/{\gamma}-Al_2O_3$ based catalysts were prepared and tested for selective oxidation of CO in a $H_2$-rich stream(1% CO, 1% $O_2$, 60% $H_2$, $N_2$ as balance). The effects of Cu loading and weight ratio(=Cu/(Cu+Ce)) upon both activity and selectivity were investigated upon the change in temperatures, It was also examined how the activity and selectivity of catalysts were varied with the presence of $CO_2$ and $H_2O$ in the reactant feed. Among the various Cu-Ce catalysts with different catalytic metal composition, Cu-Ce(4 : 16 wf%) /${\gamma}-Al_2O_3$ catalyst showed the highest activity(>$T_{99}$) and selectivities(50-80%) under wide range of temperatures($175-220^{\circ}C$). However, in the Cu-Ce(4 : 16 wt%)/ ${\gamma}-Al_2O_3$, the presence of $CO_2$ and $H_2O$ in the reactant feed decreased the activity and the maximum activity(>$T_{99}$) in terms of reaction temperature moved by about $25^{\circ}C$ toward higher temperature, the $T_{>99}$ window was seen between $210-230^{\circ}C$ (selectivity 50-75%). From $CO_2-/H_2O-TPD$, it can be concluded that the main cause for the decrease in catalytic activity may be attributed to the blockage of the active sites by competitive adsorption of water vapor and $CO_2$ with the reactant at low temperatures.

A Study on the Resident's Demands to Repair to an Energy Saving House for the Existing Apartment Housings (기존 공동주택 그린홈 개보수 제도 마련을 위한 거주자 수요 조사에 관한 연구)

  • Jung, Yoon-Hyea;Lee, Jong-Sung;Kim, Hyo-Jin;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.4 no.2
    • /
    • pp.201-209
    • /
    • 2013
  • The purpose of this study is to get some data to repair the existing apartment housings to energy saving house : The data are a repair requirement, a repair preference, and so on. For this purpose, an interview was carried out for the dwellers who is living in the estates constructed in about 10 years ago. If there would be a financial support of the government, which is to make a loan 1,400 thousand won and the 3.5% interest, then the 53% of dwellers have agreed to repair their houses. And the best preference repair item was a window, the items what is disturbed to their ordinary life would be not easy to be repaired. This survey has limited to only the apartment housings, so the additional survey will be carried out to get the data to practise the government's Green Home project for existing houses.

A study on the analysis of domestic gas explosion (실내가스폭발 해석에 관한 연구)

  • Kim Sang Sub;Cha Jae Ou
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.24-29
    • /
    • 2003
  • Numerical analysis was conducted to predict the damage of indoor gas explosion for the propagation of explosion flame. Indoor gas diffusion distribution due to gas leakage was obtained by diffusion equation that adopted initial conditions from reference. Enthalpy of each gas-mixture ratio and reduced mechanism was applied to calculate flame temperature, and laminar combustion velocities with the variant of each gas concentration from reference were applied to the gas mixture. Turbulent combustion velocity was modeled by coupling of turbulent energy and laminar combustion velocity in k-$\epsilon$ model. For the analysis of flame propagation cartesian and cylindrical coordinate were used to indoor position and flame propagation respectively. The study analyzes the cause of pressure rising with the variation of flame propagation by glass damage, and the result shows that indoor pressure rising with ignition position varies window dimension.

  • PDF