• 제목/요약/키워드: energy saving technique

검색결과 146건 처리시간 0.028초

인체감지를 통한 에너지절약 시스템 개발 (Energy Saving System Based on the Human Sensing Technique)

  • 이종필;지평식;신관우;임재윤
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.205-209
    • /
    • 2004
  • This research is investigated an energy saving system based on human detecting technique. It saves a lot of energy by automatic switching method of lighting, appliance, and so on. Existence of people on space is detected by infrared ray sensor. If there is not anybody during definite time, then main controller of system sends "power off" signal to lighting switches, and outlets. When people are detected again, turn on lighting switches and outlets. Result of this research is adaptable for classrooms and offices, and great effect of energy saving is expected.

사례연구 설문조사에 의한 주택에서의 에너지소비 실태조사와 개선방안 연구 - 제천시 거주 주민을 대상으로 - (A survey on energy consumption and improvement method for energy conservation - Targeting dwellers in Jecheon city -)

  • 이철구
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2013
  • With the architectural energy saving technique such as building insulation, airtightness etc., changing the indoor temperature and shortening the air conditioning time etc. are the good methods to practice energy saving in our lives. This study aims to seek a way to realize energy saving under investigation through a questionnaire survey about energy consumption condition and energy saving perception. 93% of the respondents recognized the need for energy saving, and 67% said more energy saving would possible in homes. Viable energy saving way was questioned by five steps method. More than 50% responded 'possible' or 'seems possible' at most of the items. Whereas less than 50% responded 'possible' or 'seems possible' at the items of 'lessening the cooling time' and 'lessening the shower time'. Ages of 50s who responded 'possible' or 'seems possible' was relatively less compared to 30s and 40s.

THE CHINESE TRADITIONAL METHODS FOR ENERGY SAVING AND THEIR APPLICATIONS IN MODER STRUCTURES

  • Chen, Jiancheng
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.617-626
    • /
    • 1993
  • Energy saving is a very important subject for research workers nowadays. While most people are concerning with the modern methods, the authors investigated this problem from another angle- the chinese traditional methods of energy saving. The tunnel with technique and its combination with computer simulation and fuzzy compressive judgement methods are discussed. Earth heat green house, marsh gas, solar energy underground storage system, storing of nature cold sources, have been introduced in this paper.

  • PDF

NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS

  • Ahmed Nabil A.;Kim Sung-Jun;Suh Ki-Young;Kown Soon-Kurl;Lee Hyun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.27-31
    • /
    • 2004
  • This paper presents a nonconventional method for oft starting of three-phase induction motors, which achieved by flux weakening technique. flux weakening is not done by reducing the applied voltage as in the conventional methods, Flus weakening is achieved y increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.

  • PDF

저온송풍 공조시스템의 열원 제어 (Control Strategy for Cold Air Distribution System)

  • 정석권;김동규;금종수;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.480-483
    • /
    • 2008
  • The cold-air distribution system is expected as an efficient method to reduce energy consumption in the air-conditioning system. We introduced some control strategies for the system by summarizing some references in the view point of energy saving. Direct digital control is specially emphasized as an important control technique for the system. Some drawbacks which habe been conventionally mentioned to apply the cold-air distribution to real fields can be solved by using the technique. The control strategy which is introduced in here will be available to build control system for the air-conditioning based on the cold-air distribution for energy saving.

  • PDF

에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구 (A Study on Refrigeration warehouse operation for Energy saving technique)

  • 김대균;권중동;함년근;이상집;김익환;이승환;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

국내 주요 가전제품의 대기전력저감기술 성과 분석 : 에너지절약 효과를 중심으로 (Analysis Result for the Technical Development Reducing Standby Power in Domestic Major Electric Appliances : The Electricity Energy Saving Effect)

  • 이은영;정순희
    • 가정과삶의질연구
    • /
    • 제27권4호
    • /
    • pp.141-160
    • /
    • 2009
  • Recently, some policies for reducing standby power, which has quite an effect on electricity consumption, have been employed all over the world. This study surveys the present condition of standby power for major electric home appliances during three years and analyzes the result of technical development reducing standby power. It presents how the industry paid attention to applying the technique of reducing standby power to electric appliances and how it affects the product's energy efficiency. We survey the standby power's change for six items, which were selected from the major electric appliances available on the market. It analyzes the difference of standby power consumption between appliances with a standby power reducing technique and those without during the latest three years. The amount of the average standby power is also compared. The comparison data confirms that the industry's effort and application of reducing standby power contribution has contributed to increasing an appliance's energy efficiency. This study restricted the analyzed items to six appliances, which has been a low volunteered involvement in the standby power reducing program. It is important for reducing standby power consumption of appliances because it contributes to saving electric energy at home and abroad. The development of the standby power reducing technique is needed for more appliances. Along with the development of the standby power reducing technique in the industrial field, it also necessary for consumers to enlarge their understanding of standby power reduction for economic, social, and environmental values.

태양광발전을 이용한 냉동.냉장창고용 냉수펌프의 에너지절감 기법 (Energy Saving Technique of Refrigeration Warehouse Cold Water Pump Using Photovoltaic Generation)

  • 김대균;전기영;이상집;정춘병;이훈구;한경희
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.92-99
    • /
    • 2005
  • 냉동 냉장창고용 냉수펌프 시스템을 태양광발전 시스템과 연계하여 펌프의 양정 및 유량의 변화에 따른 압력의 변화에도 불구하고 목표치 압력을 일정하게 제어할 수 있도록 하였다. BLDC 모터를 벡터제어 함으로써 각 운전속도의 영역에서 최대토크 운전 및 높은 신뢰성을 가능하도록 하여 냉동 냉장창고용 냉수 펌프 시스템의 에너지 절감 효과를 실현하였다.

Optimal Energy Costs based on Improving Retort Process In Food Canning Manufacturing

  • Saredchapan, Supawut;Chaikla, Amphawan;Masuchun, Ruedee;Trisuwannawat, Thanit;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2309-2312
    • /
    • 2003
  • This paper presents the minimization of the energy costs based on energy saving for industrial retort process of canned food. The approved proposed method is related the optimal steam or hot water flow control to achieve desired temperature of retort process. The smooth response and zero steady state error can be also achieved. The performances of the proposed control technique were observed using a small tuna canned food plant in Thailand as an illustrative example. The experimental results are given to support the saving in energy costs and some benefits of the proposed technique.

  • PDF