• Title/Summary/Keyword: energy saving heater

Search Result 40, Processing Time 0.03 seconds

Development of Energy Saving Electric Fan Heater (에너지 절약형 전기 온풍기 개발)

  • Kim, Jin-Bong;Koo, Dae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

Development of Electrical and Oil Heater for Energy Saving (에너지 절감형 전기 유류 겸용 온풍기 개발)

  • Chung, Sung-Won;Kim, Dong-Keon;Gong, Sang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse (탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과)

  • Paek, Y.;Jeon, J.G.;Yun, N.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part (에너지 성능지표 기계부문 항목에 따른 업무용 건물의 에너지 절감율 분석)

  • Lee, Ho Jin;Kim, Seo Hoon;Jung, Jae Uk;Jang, Cheol Yong;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.49-54
    • /
    • 2013
  • released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

Utility AC Frequency to High Frequency AC Power Frequency Converter without Electrolytic Capacitor Link for Consumer Induction Heating Appliances

  • Sugimura, H.;Eid, A.;Lee, H.W.;Kwon, S.K.;Suh, K.Y.;Nakaoka, M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1364-1367
    • /
    • 2005
  • In this paper, a novel prototype topology of soft switching PWM controlled high frequency AC power conversion circuit without DC voltage smoothing chemical capacitor filter link from the voltage grid of utility frequency AC power supply source with 60Hz-100V or 60Hz-200V is proposed and introduced for innovative consumer induction heating(IH) boiler applications as hot water producer, steamer and super heated vapor steamer.

  • PDF

A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater (에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안)

  • Jo, Man-Ki;Hong, Sung-Min;Park, Jong-Hun;Kim, Jin-Sik;Lee, Dong-Hyun;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF

Performance Verification of Curing Method in Cold-Weather with Using Energy Saving Electronic Heater for achieving Korean Carbon Neutra (탄소중립 확보를 위한 친환경 동절기 대체 열원 성능 검증)

  • Jo, Man-Ki;Kim, Sang-Kyun;Hong, Seong-Min;Park, Jong-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.192-193
    • /
    • 2021
  • Recently, the need to strengthen the Air Environment Conservation Act and secure alternative heat sources during the winter by carbon neutrality policies has been raised. Accordingly, winter construction, which has safety and quality measures, is emerging as an essential factor. It is believed that eco-friendly tropical type electric hot air heaters will be able to solve most of the problems of winter construction at construction sites, especially prevention of suffocation and fire accidents. In addition, as a result of on-site performance verification, it has secured more than the same performance as the existing curing method, and the curing technology can create an eco-friendly and pleasant working environment while considering safety and construction.

  • PDF