• Title/Summary/Keyword: energy saving

Search Result 2,714, Processing Time 0.038 seconds

The Effect of Energy-Saving Investment on Reduction of Greenhouse Gas Emissions (에너지절약투자의 온실가스 배출 감소 효과)

  • Kim, Hyeon;Jeong, Kyeong-Soo
    • Environmental and Resource Economics Review
    • /
    • v.9 no.5
    • /
    • pp.925-945
    • /
    • 2000
  • This paper analyses the impact of energy-saving investment on Greenhouse gas emissions using a model of energy demand in Korea. SUR method was employed to estimate the demand equation. The econometric estimates provide information about the energy price divisia index, sector income, and energy saving-investment elasticities of energy demand. Except for energy price divisia, the elasticities of each variable are statistically significant. Also, the price and substitution elasticities of each energy price are similar to the results reported by the previous studies. The energy-saving investment is statistically significant and elasticities of each sector is inelastic. Using the coefficient of energy-saving investment and carbon transmission coefficient, the amount of reduction of energy demand and the reduction of carbon emissions can be estimated. The simulation is performed with the scenario that the energy-saving investment increase by 10~50%, keeping up with Equipment Investment Plan of 30% increase in energy-saving investment by 2000. The results show that the reduction of energy demand measured as 11.2% based upon 1995's level of the energy demand, in industrial sector. Accordingly, the carbon emissions will be reduced by 11.3% based upon 1995's level of the carbon emissions in industrial sector.

  • PDF

An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design (에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구)

  • Kim, Tae-Hoon;Seo, Ji-Hyo;Choo, Seung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.

Trends in Mobile Network Energy-Saving Technology (모바일 네트워크 에너지 절감 기술 동향)

  • S. Jung;S.-E. Hong;J. Na
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.2
    • /
    • pp.26-35
    • /
    • 2023
  • Energy efficiency is an important factor toward sustainable future mobile network systems. As the size of the 5G mobile network system increases, the consumption and costs of energy increase. Accordingly, energy-saving optimization has become a major process in network systems, and various related technologies for energy saving are being developed. We provide a brief review of the technical trends in energy saving in 3GPP 5G & 5G Advanced systems and O-RAN systems. We focus on power models and energy-saving technologies in various resource domains of 3GPP 5G & 5G Advanced systems and energy-saving use cases of O-RAN systems.

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

Analysis on the Characteristics of Energy Use Behaviors and Energy Saving Consciousness of Multi-family Housing Residents (공동주택 거주자의 에너지 사용행태 및 에너지 절약의식 분석)

  • Lee, Youn-Jae;Lee, Hyun-Soo;Park, So-Yun
    • Journal of the Korean housing association
    • /
    • v.22 no.6
    • /
    • pp.31-42
    • /
    • 2011
  • The purpose of the study was to investigate the characteristics of energy use behaviors and energy saving consciousness of multi-family housing residents. The energy referred to in this study includes electric energy, heating energy and water usage. This study was conducted from a survey carried out in Seoul and Gyeonggi-do. The results of the study are as follows: First, among the survey questions, the only positive energy saving behaviors shown by the occupants was turning off the lights and the television, and in the use of kitchen appliances; it could therefore be concluded that, in general, energy saving attitude and consciousness were not sufficient to reduce energy consumption. Second, the results showed high mean scores for the behaviors which were easy to control, such as turning off lights and televisions, and low mean scores for the behaviors which required extra effort to completely cut off electricity energy such as pulling out the plugs of electronic appliances. Third, it was found that the occupants generally showed the tendency to save heating energy. However, in cases where the occupants were required to continuously and directly experience indoor temperatures, they expressed passive attitudes toward saving energy. Fourth, they showed wasteful attitudes toward water usage by leaving the tap running when taking showers and washing their faces. Fifth, while they showed a strong energy saving consciousness, they also showed a passive attitude about putting this into practice; there was therefore some gap between attitude and behavior. Lastly, among the socio-demographic factors, age and family lifecycle were very important factors affecting energy use and energy saving consciousness.

Cost-Effective Model for Energy Saving in Super-Tall Building

  • Song, Kwonsik;Park, Moonseo;Lee, Hyun-Soo;Kim, Sooyoung;Shin, Jinho
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.3
    • /
    • pp.17-22
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

COST-EFFECTIVE MODEL FOR ENERGY SAVING IN SUPER-TALL BUILDING

  • Kwonsik Song;Moonseo Park;Hyun-Soo Lee;Sooyoung Kim;Jinho Shin
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.294-299
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

  • PDF

A Economic Feasibility Analysis of Energy Saving Technology Application to Underground Subway Station

  • Kim, Hyungchul;Shin, Seungkwon;Jung, Hosung;Kim, Jin-o;Cha, Junmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • In Korea, new total energy-saving solution has planned to build test-bed in underground subway station. Breaking energy is one of the most energy saving method in railway, but it has not be fully used up for economical purpose. This paper demonstrates on energy saving technology application including breaking energy and heating energy to underground subway station. It also offer solution of optimization of power energy flow. Moreover, economic feasibility analysis performed for undergound test bed constuction.

Evaluation of Lighting Energy Saving Rate in a Small Office Space (소규모 사무공간의 조명에너지 절감율 평가에 관한 연구)

  • Kim, Han-Yong;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

Character Analysis of 1.2kW Proton Exchange Membrane Fuel cell (1.2kW 고분자 전해질형 연료전지 특성 분석)

  • Kim, Sung-Jun;Choi, Kwang-Ju;Kwon, Soon-Kurl;Suh, Ki-Young;Nakaoka, M.;Lee, Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.781-784
    • /
    • 2005
  • This paper is aimed at presenting a proton exchange membrane ( PEM ) fuel cell stack. The fuel cell electrical output voltage and current (V-I) characteristic is described for the first time by a simplified closed form suitable. The characteristics obtained from the simulation are compared with the experimental results on a Ballard commercial fuel cell stack as well as to the manufacturer given data.

  • PDF