• 제목/요약/키워드: energy retrofit

검색결과 165건 처리시간 0.022초

Mechanics model of novel compound metal damper based on Bi-objective shape optimization

  • He, Haoxiang;Ding, Jiawei;Huang, Lei
    • Earthquakes and Structures
    • /
    • 제23권4호
    • /
    • pp.363-371
    • /
    • 2022
  • Traditional metal dampers have disadvantages such as a higher yield point and inadequate adjustability. The experimental results show that the low yield point steel has superior energy dissipation hysteretic capacity and can be applied to seismic structures. To overcome these deficiencies, a novel compound metal damper comprising both low yield point steel plates and common steel plates is presented. The optimization objectives, including "maximum rigidity" and "full stress state", are proposed to obtain the optimal edge shape of a compound metal damper. The numerical results show that the optimized composite metal damper has the advantages such as full hysteresis curve, uniform stress distribution, more sufficient energy consumption, and it can adjust the yield strength of the damper according to the engineering requirements. In view of the mechanical characteristics of the compound metal damper, the equivalent model of eccentric cross bracing is established, and the approximate analytical solution of the yield strength and the yield displacement is proposed. A nonlinear simulation analysis is carried out for the overall aseismic capacity of three-layer-frame structures with a compound metal damper. It is verified that a compound metal damper has better energy dissipation capacity and superior seismic performance, especially for a damper with double-objective optimized shape.

구조물 내진보강법에 따른 저층 건축물의 내진성능평가 (Seismic Performance Evaluation of the Low-Rise Buildings with Different Seismic Retrofit Procedures)

  • 송민아;이시철;이기학
    • 한국지진공학회논문집
    • /
    • 제20권7_spc호
    • /
    • pp.553-560
    • /
    • 2016
  • After an earthquake occurred in the Gyeongju, 2016, many low-story buildings have been questioned in terms of the seismic performance since mostly they have been exempted from the seismic design requirement since 1988. In this study, a 3-story moment resisting frame (MRF) building was analyzed and evaluated the seismic performance. Due to the insufficient seismic performance required for the seismic performance levels, three different seismic retrofit schemes were proposed and their seismic performances were re-evaluated. While steel brace and open shear wall retrofit systems mainly focused on the strength retrofit, the VES damper retrofit system is mainly to enhance the energy dissipation capacity of the system and resultes in the increased ductility. The original building and 3 retrofitted buildings were evaluated using the nonlinear static and nonlinear dynamic analyses and suggestions were proposed. Through the analysis of nonlinear time history and push-over using MIDAS/Gen program, damages of the building in terms of top story and average story drift and effect of reinforcement were analyzed.

단부 파쇄형 휨 보강에 따른 철근콘크리트 전단벽 휨 성능 평가 (Evaluation of Flexural Performance of Reinforced Concrete Shear Walls According to Flexural Retrofit by Wall End Excavating)

  • 조의진;김수용;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제36권4호
    • /
    • pp.123-133
    • /
    • 2020
  • The purpose of this study is to analyze the method of retrofitting flexural strength and the flexural performance of retrofitted shear walls. There are various ways to reinforce the flexural strength of reinforced concrete shear wall structural systems that have already been built, in the case of that, the external force is increased, and the internal force is insufficient. However, there are various problems, such as excessive flexural stiffness after reinforcement and increasing the thickness and length of the wall. We have developed a retrofit method to solve these problems. The wall end is excavated to place the required vertical rebars, and concrete is poured after placing rebars. This is the same concept as creating wall end boundary elements later on. We also studied the anchorage method of reinforcement and the interaction method between the retrofitting end and the existing wall. The flexural test results for the reinforced concrete shear wall using the studied retrofit method can be predicted according to the sectional analysis and FEM analysis, and there are differences in the plastic hinge length, crack propagation, stiffness degradation and energy dissipation due to the bending depending on the vertical rebar ratio of wall end.

A methodology for design of metallic dampers in retrofit of earthquake-damaged frame

  • Zhang, Chao;Zhou, Yun;Weng, Da G.;Lu, De H.;Wu, Cong X.
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.569-588
    • /
    • 2015
  • A comprehensive methodology is proposed for design of metallic dampers in seismic retrofit of earthquake-damaged frame structures. It is assumed that the metallic dampers remain elastic and only provide stiffness during frequent earthquake (i.e., earthquake with a 63% probability of exceedance in 50-year service period), while in precautionary earthquake (i.e., earthquake with a 10% probability of exceedance in 50-year service period), the metallic dampers yield before the main frame and dissipate most of the seismic energy to either prevent or minimize structural damages. Therefore by converting multi-story frame to an equivalent single-degree-of-freedom system, the added stiffness provided by metallic dampers is designed to control elastic story drifts within code-based demand under frequent earthquake, and the added damping with the combination of added stiffness influences is obtained to control structural stress within performance-based target under precautionary earthquake. With the equivalent added damping ratio, the expected damping forces provided by metallic dampers can be calculated to carry out the configuration and design of metallic dampers along with supporting braces. Based on a detailed example for retrofit of an earthquake-damaged reinforced concrete frame by using metallic dampers, the proposed design procedure is demonstrated to be simple and practical, which can not only meet current China's design codes but also be used in retrofit design of earthquake-damaged frame with metallic damper for reaching desirable performance objective.

한국의 어린이 건강과 에너지 효율성을 기반으로 한 친환경 리모델링을 위한 우선순위 전략 프레임워크 (A strategic framework for green remodeling based on children's health and energy efficiency in South Korea)

  • 응우옌 티 비 안;안용한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.61-62
    • /
    • 2023
  • Promoting energy-efficient retrofit of existing buildings to achieve carbon neutrality by 2050 is critically vital and challenging. The bulk of outdated educational buildings in particular are of grave concern since they are not only have a significant negative impact on the environment but also dangerous to inhabitants'health. This study laid the groundwork for understanding the connection between occupant health and energy efficiency. This study proposes a prioritized strategic GR framework in South Korea's aging preschools. The possible prospects and levels of development in the GR plan are identified by this evaluation. Policy markers, educators, and other key stakeholders may help to create a more sustainable and healthy environment by putting the recommended framework into practice.

  • PDF

External retrofit of beam-column joints in old fashioned RC structures

  • Adibi, Mahdi;Marefat, Mohammad S.;Arani, Kamyar Karbasi;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제12권2호
    • /
    • pp.237-250
    • /
    • 2017
  • There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.

래핑 복합플레이트를 이용한 공공시설의 내진보강 (Seismic Retrofit of the Public Facilities Using the Wrapping Composite Plate)

  • 박춘욱
    • 한국공간구조학회논문집
    • /
    • 제23권3호
    • /
    • pp.45-55
    • /
    • 2023
  • The purpose of this study has a purpose to evaluate shear ability, ductility and energy dissertation of specimens that is to be applied to jacket using wrapping method. The experiments was conducted as a condition that simultaneously applied axial load and transverse force. The results of experiments represent story-displacement ratio, the stiffness, energy dissertation, plastic rotation which mean seismic resistance ablity on structure. And It represents the form of crack ditribution and failure in extreme stages. Based on the results of this experiment, Design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted. Therefore, it is possible to apply the seismic retrofit method to public facilities.

건물에너지합리화사업 - 서울시 맑은환경본부 에너지정책담당관 이창학 과장 (BRP, Building Retrofit Project)

  • 에너지절약전문기업협회
    • ESCO지
    • /
    • 통권57호
    • /
    • pp.52-55
    • /
    • 2009
  • 서울시에서 추진하고 있는 건물에너지합리화사업(BRP, Building Retrofit Project)은 건물 소유자 또는 에너지 사용자가 주체가 되어 에너지 사용실태와 낭비요인을 파악하기 위해 에너지 진단을 실시하고 그 결과를 참고하여 건물에서의 에너지 절감 및 이용효율을 향상시키는 시설개선사업이다. 이를 통해 2013년 도쿄의정서를 대비하고 앞으로 서울을 친환경적 세계도시로 조성해 나가기 위해 앞장서고 있는 서울시의 맑은환경본부 에너지정책담당관 이창학 과장을 만났다.

  • PDF

Seismic retrofit of structures using added steel column friction dampers

  • Mohammad Mahdi Javidan;Asad Naeem;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제49권3호
    • /
    • pp.257-270
    • /
    • 2023
  • In this study, the feasibility and applicability of a friction damper with a vertical installation scheme are investigated. This device is composed of a steel section and two friction hinges at both ends which dissipate seismic energy. Due to its small width and vertical installation scheme, the proposed damper can minimize the interference with architectural functions. To evaluate the performance of the proposed damper, its mechanical behavior is theoretically evaluated and the required formulas for the yield strength and elastic stiffness are derived. The theoretical formulas are verified by establishing the analytical model of the damper in the SAP2000 software and comparing their results. To further investigate the performance of the developed damper, the provided analytical model is applied to a 4-story reinforced concrete (RC) structure and its performance is evaluated before and after retrofit under the Maximum Considered Earthquake (MCE) hazard level. The seismic performance is thoroughly evaluated in terms of maximum interstory drift ratio, displacement time history, residual displacement, and energy dissipation. The results show that the proposed damper can be efficiently used to protect the structure against seismic loads.

선박개조에 따른 고객 맞춤형 기성품 선형 개발 (Study on the Development of the Customized Ready-Made Hull Forms according to the Retrofit)

  • 박동우
    • 해양환경안전학회지
    • /
    • 제23권4호
    • /
    • pp.432-438
    • /
    • 2017
  • 본 연구의 주목적은 기존선형을 바탕으로 연료 절감이 가능한 표준화된 개조선형을 개발하는 것이다. 설계 흘수와 설계 선속을 고려하여 대상선박의 선수부 형상을 검토하였다. 실제 운항 상태 별로 대상선박에 대하여 저항성능을 평가하였다. 상용 전산유체역학(CFD) 코드와 수조 모형시험 자료는 유효마력 평가를 위해 사용되었다. 실제 운항 상태를 고려하여 최소저항을 가지는 3가지 개조선형을 제시하였다. 제시된 개조선형은 고객이 선택가능 하다는 점에서 고객 맞춤형 기성품 선형이라고 명하였다. 개조선형 별로 실제 운항 상태에 따라 유효마력을 추정하였다. 가장 낮은 흘수에서 운항할 경우, 기존선형과 비교하여 볼 때 개조3 선형의 저항성능은 저속영역인 16~18노트에서 약 11~16 %로 향상된 결과를 보여 주었다. 중간 흘수인 8.3m에서 운항할 경우, 개조3 선형의 저항성능은 저속영역에서 기존선형보다 약 6~11 %로 향상된 결과를 보여 주었다. 가장 높은 흘수인 9.5m에서 운항할 경우, 모든 선형의 저항성능은 저속영역에서 큰 차이를 보이지 않았다.