• Title/Summary/Keyword: energy recovery.

Search Result 1,677, Processing Time 0.028 seconds

Optimum Design on the Mixed Ratio of Injection Gas with CO2/N2 in Enhanced Coalbed Methane Recovery (석탄층 메탄가스 회수증진공법에서 CO2/N2 주입가스의 혼합 비율 최적 설계)

  • Yoo, Hyun-Sang;Kim, Young-Min;Lee, Jeong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.1-9
    • /
    • 2017
  • Enhanced coalbed methane recovery (ECBM), as injecting $CO_2$ or $N_2$ into the coalbed methane (CBM) reservoir for increasing methane recovery, takes center stage in these days. ECBM makes a better recovery than the conventional production method, it called dewatering process. However the characteristics of injection gas affect to methane recovery, thus analysis on the mixed ratio of injection gas should be required. In this study, CBM reservoir model was built to estimate the methane recovery of ECBM method by different mixed ratio of injection gas. Additionally, to consider the characteristics of injection gas such as carbon captured storage, nitrogen re-injection, etc. economic analysis was performed. The results showed that ECBM cases produced methane almost twice as much as dewatering case and $CO_2$ 10% and $N_2$ 90% case resulted in the highest methane recovery among the mixed gas cases. On the other hand, the results of economic analysis showed that $CO_2$ 20% and $N_2$ 80% case made the highest total production profit. Therefore, both the recovery of methane and economical efficiency should be considered to apply ECBM process.

A New High-Efficient Energy-Recovery Circuit for Plasma Display Panel (새로운 에너지 회수 방식을 채용한 고효율 PDP 구동 회로)

  • 韓 翔 圭;李 俊 榮;文 建 又;尹 明 重;朴 昌 培;丁 南 聲;朴 正 泌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 2002
  • A new high-efficient energy-recovery circuit is proposed to drive a plasma display panel (PDP) and compared with the conventional circuit. The proposed circuit uses only two inductors and no auxiliary circuit to recover the energy stored in the equivalent intrinsic capacitance of PDP. Therefore it features a simpler structure, less mass, lower cost of production, higher efficiency, and fewer power devices. The very stable and uniform light emitted from PDP proves the high quality of screen. It is suitable for wall-hanging color TVs. The proposed circuit, operating at 200kHz, is verified to be applicable on a 42-inch PDP by experimental results.

Hybrid Three-Level DC/DC Converter using an Energy Recovery Snubber (에너지회생스너버를 적용한 하이브리드 3레벨 DC/DC 컨버터)

  • Heo, Ye-Chang;Joo, Jong-Seong;Harerimana, Elysee-Malon;Kim, Eun-Soo;Kang, Cheol-Ha;Lee, Seung-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.36-43
    • /
    • 2017
  • This paper describes a hybrid multi-output three-level DC/DC converter suitable for a wide, high-input voltage range of an auxiliary power supply for a high-power photovoltaic generating system. In a high-power photovoltaic generating system, the solar panel output voltage depends on solar radiation quantity and varies from 450Vdc to 1100Vdc. The proposed hybrid multi-output three-level DC/DC converter, which is an auxiliary power supply, would be used as power source for control printed circuit boards and relay and cooling fans in a high-power photovoltaic generating system. The proposed multi-output ($24V_{DC}/30A$, $230V_{DC}/5A$) hybrid three-level boost converter, which uses an energy recovery snubber, is controlled by variable-frequency and phase-shifted modulations and can achieve zero-voltage switching with all operating conditions of input voltage and load range. Experimental results of a 2kW prototype are evaluated and implemented to verify the performance of the proposed converter.

High Efficient Energy Recovery Circuit for AC Plasma Display Panel (AC Plasma Display Panel 구동 장치의 고효율 전력 회수 회로에 관한 연구)

  • 윤원식;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.481-488
    • /
    • 2001
  • The sustaining driver for color AC Plasma Display Panel should provide alternating high voltage pulses and recover the energy discharged from the intrinsic capacitance between the scanning and sustaining electrodes inside the panel In this paper a novel efficient energy recovery circuit employing boost-up function is proposed to achieve a faster rise-time and in order to obtain a stable sustain voltage The principle of operation. features simulated results and experiment results are illustrated and verified on a 7.5-inch-panel with 200[kHz]switch frequency.

  • PDF

Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor (자본회수계수를 고려한 고효율 생산설비의 경제성분석)

  • Park, Hyung-Joon;Chung, Chcn-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.117-123
    • /
    • 2007
  • This paper is about the economic analysis of the replacement of electric facilities in the production facilities. As the interest of energy is increasing, the efficiency of facilities become more important. So, in this paper, we diagnosed facilities, especially electric motors, in the plant and calculated the operating efficiency, power loss with the load factor. And when we replace these facilities into high-efficiency motors, we also calculated new energy efficiency, energy loss and economic analysis through capital recovery factor. As a result, we economically proved that using high-efficiency motor is more beneficial than using non-high-efficiency motors in the model process.

Three Level DC/DC Converter Using Energy Recovery Snubber (에너지 회생 스너버를 적용한 3레벨 DC/DC 컨버터)

  • 조용현;김윤호;김은수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.64-73
    • /
    • 2001
  • This paper presents a Zero Voltage and Zero Current Switching (ZVZCS) 3-Level DC/DC converter. This converter overcomes the drawbacks presented by the conventional Zero Voltage Switching(ZVS) 3-Level converter, such as high circulating energy, severe parastic ringing on the rectifier diodes, and limited ZVS load range for the inner switches. The converter presented in this paper uses a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switches. Additionally, the converter uses an energy recovery snubber to reset the primary current during the free-wheeling stage to achieve ZCS for the inner switches. The proposed converters are analyzed and verified on 6kW, 39kHz experimental prototype.

  • PDF

Smart Honeycomb Sandwich Panels With Damage Detection and Shape Recovery Functions

  • Okabe, Yoji;Minakuchi, Shu;Shiraishi, Nobuo;Murakami, Ken;Takeda, Nobuo
    • Advanced Composite Materials
    • /
    • v.17 no.1
    • /
    • pp.41-56
    • /
    • 2008
  • In this research, optical fiber sensors and shape memory alloys (SMA) were incorporated into sandwich panels for development of a smart honeycomb sandwich structure with damage detection and shape recovery functions. First, small-diameter fiber Bragg grating (FBG) sensors were embedded in the adhesive layer between a CFRP face-sheet and an aluminum honeycomb core. From the change in the reflection spectrum of the FBG sensors, the debonding between the face-sheet and the core and the deformation of the face-sheet due to impact loading could be well detected. Then, the authors developed the SMA honeycomb core and bonded CFRP face-sheets to the core. When an impact load was applied to the panel, the cell walls of the core were buckled and the face-sheet was bent. However, after the panel was heated over the reverse transformation finish temperature of the SMA, the core buckling disappeared and the deflection of the face-sheet was relieved. Hence the bending stiffness of the panel could be recovered.

Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank (3중관 튜브형 잠열 축열조에서의 열전달 특성 연구)

  • Lee, W.K.;Han, G.Y.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

Heat transfer characteristics of Immersed Coil Type Latent Heat Storage Tank (내부코일형 잠열 축열조에서의 열전달 특성 연구)

  • Lee, W.K.;Han, G.Y.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.83-91
    • /
    • 2001
  • The heat transfer experiment in a pilot scale latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of three parts; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and immersed coil in the PCM vessel for hot water recovery. The heat storage tank has the dimension of 115 cm in height and 32 cm outside diameter. Paraffin wax (m.p = 55.4C) and sodium acetate trihydrate (m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage $(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

[ $CO_2$ ] Sequestration on Various Structures of Natural Gas Hydrate Layer for Effective Recovery of $CH_4$ Gas

  • Park, Young-June;Choi, Suk-Jeong;Shin, Kyu-Chul;Seol, Ji-Woong;Lee, Hu-En
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.410-411
    • /
    • 2006
  • On the continental margins and in permafrost regions, natural gas, which has been expected to replace petroleum energy, exists In solid hydrate farm. World hydrate reserves Including natural gas are estimated at about twice as much as the energy contained In total fossil fuel reserves. Because of its vast quantities, the efficient recovery of natural gas from natural gas hydrate becomes the most important factor on evaluating the economic feasibility in the sense of commercialization. It has been noted that carbon dioxide, one of the well-known green house gases, possibly can be stored in the ocean floor as a carbon dioxide hydrate. If the natural gas hydrate could be converted into carbon dioxide hydrate, natural gas hydrate deposits would serve as energy sources as well as carbon dioxide storage sites in the deep ocean sediments. In this study, we first attempted to examine the real swapping phenomenon occurring between guest molecules and various structures of gas hydrate through spectroscopic identification such as NMR spectroscopy.

  • PDF