• 제목/요약/키워드: energy performance

검색결과 14,544건 처리시간 0.035초

실험을 통한 BIPV/T 시스템 성능분석-1. PV 발전효율 (Performance Analysis of the BIPV/T system by the performance Test- Part1. PV efficiency)

  • 이현주;조혜진
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.445-450
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The efficiency of the PV system's performance will raise by the system removes heat from the PV. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The planned experiment is following. (1) Supplying heat energy to top floor. (2) Supplying heat and cool energy to thermal storage in the bottom of the top floor. (3) Supplying heat energy to EHP for improved performance. The experimental performance is executed from 13th February to 13th March, 2012. The solar generation of electricity is 4.04kWh under the horizontal solar radiation is $1000W/m^2$ and the air temperature is $25^{\circ}C$.

  • PDF

재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가 (Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster)

  • 박병용;조진균;정용대;이원학
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

Zero Energy School(ZES) 에너지절감 성과 검증을 위한 방법론 연구 (A methodology for verification of energy saving performance of Zero Energy School (ZES))

  • 이항주;안종욱;김인수
    • 에너지공학
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2019
  • 국내 건축물은 국가 온실가스 배출의 25%, 에너지소비의 20%를 차지하고 있어 건축물의 에너지 효율향상이 국가 에너지수요관리의 주 대상으로 인식되고 있다. 건축물의 에너지효율향상을 위해 "제로에너지건축물 국가 로드맵"을 작성하여 정책들을 시행하고 있으며, 제로에너지건축물 의무화 확대의 따라 조기 활성화를 통한 국가 건물에너지 수요관리 효율성을 제고 하고 있다. 또한 건축물이 완공되고 그 후 에너지절감량에 대한 성과검증에 대한 필요성 또한 높아지고 있다. 이에 따라 건축물의 에너지 성능을 평가하기 위한 방법들이 제시되어야 할 것이다. 본 논문은 국제표준 및 가이던스 분석과 동시에 국내 학교를 현장 방문하여 각종 변수 등에 대한 조사 분석을 통하여 국제적으로 적용 가능한 제로에너지스쿨의 에너지성과검증 방법을 개발, 제시하고자 한다.

Low-power Scheduling Framework for Heterogeneous Architecture under Performance Constraint

  • Li, Junke;Guo, Bing;Shen, Yan;Li, Deguang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권5호
    • /
    • pp.2003-2021
    • /
    • 2020
  • Today's computer systems are widely integrated with CPU and GPU to achieve considerable performance, but energy consumption of such system directly affects operational cost, maintainability and environmental problem, which has been aroused wide concern by researchers, computer architects, and developers. To cope with energy problem, we propose a task-scheduling framework to reduce energy under performance constraint by rationally allocating the tasks across the CPU and GPU. The framework first collects the estimated energy consumption of programs and performance information. Next, we use above information to formalize the scheduling problem as the 0-1 knapsack problem. Then, we elaborate our experiment on typical platform to verify proposed scheduling framework. The experimental results show that our proposed algorithm saves 14.97% energy compared with that of the time-oriented policy and yields 37.23% performance improvement than that of energy-oriented scheme on average.

Considerations of Sustainable High-rise Building Design in Different Climate Zones of China

  • Wan, Kevin K.W.;Chan, Man-Him;Cheng, Vincent S.Y.
    • 국제초고층학회논문집
    • /
    • 제1권4호
    • /
    • pp.301-310
    • /
    • 2012
  • Buildings, energy and the environment are key issues that the building professions and energy policy makers have to address, especially in the context of sustainable development. With more tall buildings constructed in China, the impact on energy consumption and carbon emission would be great from buildings (2% increase of carbon dioxide annually between 1971 and 2004). The imperative was to investigate the building energy performance of high-rise in different climate zones and identify the key design parameters that impose significantly influence on energy performance in sustainable building design. Design implications on glazing performance, sizing of the ventilation fans, renewable energy application on high-rise building design are addressed. Combination of effective sustainable building design strategies (e.g., building envelope improvement, daylight harvesting, advanced lighting design, displacement ventilation, chilled ceiling etc.) could contribute more than 25% of the total building energy consumption compared to the international building energy code.

에너지 해석을 통한 대학건물의 에너지 성능개선 방안에 관한 연구 (A Study on the Improvement Plans of Energy Performance in University Building through the Analysis of Energy)

  • 정재웅;김동우;석호태;양정훈
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.50-60
    • /
    • 2010
  • Today, the amount of energy consumption in the university campuses is huge. The effort for the energy consumption reduction in university campuses is certainly needed by the following reason; first, contribution to the greenhouse gas discharge reduction demand. Second, energy cost reduction in university campus. Third, contribution to the improvement of the social awareness as the maximum higher educational institutions. The energy consumption analysis of current situation has to be executed for the energy consumption reduction in university campus. The energy reduction possibility in which it exists in university campuses can be understood through the energy consumption analysis. And the application is possible as fundamental data of the policy establishment for the effective energy reduction in university campuses. Especially, the best way to reduce the energy consumption in university campuses that is the energy consumption reduction of buildings. Accordingly, this study derived the plans for improving the performance of energy in the university building by analyzing case study, so this study analyzed the performance of energy for the university building through VE, a program for the analysis of building energy. Based on this result, this study classified the plans improving the efficiency of energy in university building into the plan for passive control and active control respectively, and suggested some concrete plans, and finally evaluated the performance of decreasing energy consumption for each plan.

필름 히터를 이용한 스마트 팜 난방 성능 설계에 관한 연구 (A Study on the Design of Smart Farm Heating Performance using a Film Heater)

  • 김웅
    • 소성∙가공
    • /
    • 제32권3호
    • /
    • pp.153-159
    • /
    • 2023
  • This paper presents the optimal design of a heating system using radiant heating elements for application in smart farms. Smart farming, an advanced agricultural technology, is based on artificial intelligence and the internet of things and promotes crop production. Temperature and humidity regulation is critical in smart farms, and thus, a heating system is essential. Radiant heating elements are devices that generate heat using electrical energy. Among other applications, radiant heating elements are used for environmental control and heating in smart farm greenhouses. The performance of these elements is directly related to their electrical energy consumption. Therefore, achieving a balance between efficient electrical energy consumption and maximum heating performance in smart farms is crucial for the optimal design of radiant heating elements. In this study, the size, electrical energy supply, heat generation efficiency, and heating performance of radiant heating elements used in these heating systems were investigated. The effects of the size and electrical energy supply of radiant heating elements on the heating performance were experimentally analyzed. As the radiant heating element size increased, the heat generation efficiency improved, but the electrical energy consumption also increased. In addition, increasing the electrical energy supply improved both the heat generation efficiency and heating performance of the radiant heating elements. Based on these results, a method for determining the optimal size and electrical energy supply of radiant heating elements was proposed, and it reduced the electrical energy consumption while maintaining an appropriate heating performance in smart farms. These research findings are expected to contribute to energy conservation and performance improvement in smart farming.

분사노즐 형상 변화와 초음파 에너지 부가장치를 이용한 디젤기관의 성능특성(I) (Performance Characteristics of a Diesel Engine Using the Change of Injection Nozzle Type and Ultrasonic-Energy-Added System(I))

  • 최두석;류정인
    • 한국자동차공학회논문집
    • /
    • 제5권4호
    • /
    • pp.160-170
    • /
    • 1997
  • The objective of this study is to investigate the atomization characteristics and the performance characteristics of a C. I. engine by using the changes of the injection nozzle type and the ultrasonic-energy-added system. In order to evaluate the effect of ultrasonic energy and of change of injection nozzle type in the performance characte- ristics of a diesel engine, measurements of droplet size of diesel fuel were carried out by using Malvern system. In all types of injection nozzles, SMD of the ultrasonic- energy -added diesel fuel was smaller than that of the conventional diesel fuel and the more injection pressure increased, the more SMD decreased. There was a small increase in SMD with the distance from injection nozzle under all conditions of the injection nozzle types. The minimum SMD was found in the injection nozzle of B type. In the diesel engine test, there were three results about the engine performance. Compared with the injection nozzle of A type, B type had excellent effects in the engine performance. The most excellent effects about the engine performance were obtained in the case of ultrasonic-energy-added diesel fuel. In addition, the torque diagram in the case of ultrasonic-energy-added diesel fuel was more stable and periodical than others.

  • PDF

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • 제20권3호
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.

에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구 (An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design)

  • 김태훈;서지효;추승연
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.