• 제목/요약/키워드: energy model

검색결과 11,717건 처리시간 0.039초

Adaptive Active Contour Model: a Localized Mutual Information Approach for Medical Image Segmentation

  • Dai, Shuanglu;Zhan, Shu;Song, Ning
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권5호
    • /
    • pp.1840-1855
    • /
    • 2015
  • Troubles are often met when traditional active contours extract boundaries of medical images with inhomogeneous bias and various noises. Focusing on such a circumstance, a localized mutual information active contour model is discussed in the paper. By defining neighborhood of each point on the level set, mutual information is introduced to describe the relationship between the zero level set and image field. A driving energy term is then generated by integrating all the information. In addition, an expanding energy and internal energy are designed to regularize the driving energy. Contrary to piecewise constant model, new model has a better command of driving the contours without initialization.

A PRESSURE DROP MODEL FOR PWR GRIDS

  • Oh, Dong-Seok;In, Wang-Ki;Bang, Je-Geon;Jung, Youn-Ho;Chun, Tae-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.483-488
    • /
    • 1998
  • A pressure drop model for the PWR grids with and without mixing device is proposed at single phase based on the fluid mechanistic approach. Total pressure loss is expressed in additive way for form and frictional losses. The general friction factor correlations and form drag coefficients available in the open literatures are used to the model. As the results, the model shows better predictions than the existing ones for the non-mixing grids, and reasonable agreements with the available experimental data for mixing grids. Therefore it is concluded that the proposed model for pressure drop can provide sufficiently good approximation for grid optimization and design calculation in advanced grid development.

  • PDF

Ground-Coupled 바닥구조체의 열전달 모델링 (An Approach to Model Ground-Coupled Building Foundation for Energy Simulation)

  • 임병찬
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.658-666
    • /
    • 2004
  • In this paper, a two-dimensional transient ground-coupled numerical model for slab-on-grade foundation is developed and integrated into EnergyPlus. A validation analysis is first presented to ensure that for the developed building foundation heat transfer module is properly implemented within EnergyPlus. Then, the predictions from the developed model are compared to those obtained from the simplified building foundation model currently used in EnergyPlus. The results show that the developed foundation heat transfer module accounts better for the effects of the ground thermal mass attributed to the ground than the simplified foundation model currently used in EnergyPlus.

Implementation of an Operator Model with Error Mechanisms for Nuclear Power Plant Control Room Operation

  • Suh, Sang-Moon;Cheon, Se-Woo;Lee, Yong-Hee;Lee, Jung-Woon;Park, Young-Taek
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.349-354
    • /
    • 1996
  • SACOM(Simulation Analyser with Cognitive Operator Model) is being developed at Korea Atomic Energy Research Institute to simulate human operator's cognitive characteristics during the emergency situations of nuclear power plans. An operator model with error mechanisms has been developed and combined into SACOM to simulate human operator's cognitive information process based on the Rasmussen's decision ladder model. The operational logic for five different cognitive activities (Agents), operator's attentional control (Controller), short-term memory (Blackboard), and long-term memory (Knowledge Base) have been developed and implemented on blackboard architecture. A trial simulation with a scenario for emergency operation has been performed to verify the operational logic. It was found that the operator model with error mechanisms is suitable for the simulation of operator's cognitive behavior in emergency situation.

  • PDF

Impact by Estimation Error of Hourly Horizontal Global Solar Radiation Models on Building Energy Performance Analysis on Building Energy Performance Analysis

  • Kim, Kee Han;Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.3-10
    • /
    • 2014
  • Impact by estimation error of hourly horizontal global solar radiation in a weather file on building energy performance was investigated in this study. There are a number of weather parameters in a given weather file, such as dry-bulb, wet-bulb, dew-point temperatures; wind speed and direction; station pressure; and solar radiation. Most of them except for solar radiation can be easily obtained from weather stations located on the sites worldwide. However, most weather stations, also including the ones in South Korea, do not measure solar radiation because the measuring equipment for solar radiation is expensive and difficult to maintain. For this reason, many researchers have studied solar radiation estimation models and suggested to apply them to predict solar radiation for different weather stations in South Korea, where the solar radiation is not measured. However, only a few studies have been conducted to identify the impact caused by estimation errors of various solar radiation models on building energy performance analysis. Therefore, four different weather files using different horizontal global solar radiation data, one using measured global solar radiation, and the other three using estimated global solar radiation models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM) were packed into TRY formatted weather files in this study. These were then used for office building energy simulations to compare their energy consumptions, and the results showed that there were differences in the energy consumptions due to these four different solar radiation data. Additionally, it was found that using hourly solar radiation from the estimation models, which had a similar hourly tendency with the hourly measured solar radiation, was the most important key for precise building energy simulation analysis rather than using the solar models that had the best of the monthly or yearly statistical indices.

그린리모델링 효과평가를 위한 표준공동주택 정밀에너지해석모델 보정과 검증 (Calibration and Verification of Detailed Prototypical Apartment Building Energy Models for Estimation of Green Remodeling Feasibility)

  • 서동현
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.9-17
    • /
    • 2024
  • 표준건물 에너지모델은 정책, 연구 및 기술개발 등에 다양한 활용성이 있다. 상세 에너지해석용 표준공동주택모델이 서동현 외(2014)에 의해 제안되었으나, 모델의 에너지소비량 예측에 성능 검증용 신뢰성 있는 측정데이터가 없어 충분한 검증이 이루어지지 못하였다. 그러나, 최근 에너지경제연구원(KEEI)에서 매년 발표하는 가구에너지패널조사(HEPS) 데이터를 분석하여 공동주택 벤치마크데이터를 발표한 연구에 힘입어 검증이 가능하게 되었다. 이 연구는 이 검증용 데이터를 이용하여 표준공동주택 에너지모델을 중부지역, 2000년 이전 모델을 기준으로 보정하고, 보정된 모델을 이용하여 지역과 준공년도가 그룹에도 유효한 성능을 보여주는지 검증하였다. 검중에는 중부, 남부 각 5개씩의 대표도시 표준기상데이터가 이용되었고, 18개의 그룹에서 대부분 MBE, cv(RMSE) 기준을 만족하는 결과를 도출하였다.

간략화된 배터리 모델이 적용된 IUIa 충전 방식의 에너지 저장장치의 PSCAD/EMTDC 시뮬레이션 모델에 관한 연구 (A Study on the PSCAD/EMTDC Simulation Model of Battery Energy Storage with Simplified Battery Model and IUIa Charging Method)

  • 김성현;이계병;홍준희;손광명
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.84-90
    • /
    • 2010
  • In order to level electric power of the photovoltaic and wind-turbine system and ensure fast response of the fuel-cell and micro-turbine, the energy storage is required in the microgrid system. In this paper, a simplified simulation model of the battery energy storage for charging method with IUIa is developed using PSCAD/EMTDC. The model consists of e.m.f.(electromotive force), internal resistor and overvoltage capacitor. A method for deciding parameters of the model on a case-by-case basis is proposed. The developed model can be used in the simulation of a complicated system such as a microgrid system.

시계열 자료 분석기법에 의한 풍속 예측 연구 (Estimation Model of Wind speed Based on Time series Analysis)

  • 김건훈;정영석;주영철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2008
  • A predictive model of wind speed in the wind farm has very important meanings. This paper presents an estimation model of wind speed based on time series analysis using the observed wind data at Hangyeong Wind Farm in Jeju island, and verification of the predictive model. In case of Hangyeong Wind Farm and Haengwon Wind Farm, The ARIMA(Autoregressive Integrated Moving Average) predictive model was appropriate, and the wind speed estimation model was developed by means of parametric estimation using Maximum likelihood Estimation.

  • PDF

무선 통신 시스템의 전력 모델을 이용한 비트당 최소 에너지 (Minimum Energy Per Bit by Power Model in the Wireless Transceiver System)

  • 최재훈;조병각;백광훈;유흥균
    • 한국전자파학회논문지
    • /
    • 제22권12호
    • /
    • pp.1078-1085
    • /
    • 2011
  • 본 논문은 RF power model과 주파수 대역의 특성을 이용한 비트 당 에너지와 전송량과의 관계를 시스템 대역폭의 변화에 따라 분석한 논문이다. 기존에 제안된 RF power model은 각각의 디바이스의 소모 전력을 수식적으로 표현한 것이다. 이 전력 모델에 고려된 요소는 시스템의 전송 대역과 PAR, 데이터 전송량, 변조 레벨, 전송, 전송 거리 등이다. 본 논문에서는 이러한 영향을 고려하여 RF power model과 주파수 대역의 특성을 이용한 비트당 에너지와 전송량의 관계를 시스템 대역폭의 변화에 따라 분석하였다. Shannon capacity 공식과 신호의 SNR에 대한 식, 그리고 RF power model의 소모 전력을 이용하여 해당 주파수에서의 소모 전력을 구하고, Gbps급 데이터 속도에 따른 비트 당 에너지의 최소 값을 찾기 위한 시뮬레이션을 진행하였다.

수중 폭발음의 에너지 스펙트럼 (Energy Spectrum of Underwater Explosive Sound)

  • 김성부
    • 한국음향학회지
    • /
    • 제9권3호
    • /
    • pp.56-61
    • /
    • 1990
  • 수중폭발음의 Energy spectrum 분석에 보다 정밀한 이론적 뒷받침을 하기 위하여 폭발음의 파형에 Gaussian formula를 도입하였으며 이 파형에 따른 Energy spectrum 모델을 새로이 유도하였다. Impulse formula를 이용한 Weston 모델이 낮은 폭발 에너지나 음원의 작동수심이 깊을 경우 이론적 모델로서 한계성을 갖는데 비해 이 모델은 이러한 조건에서도 실험결과와 잘 일치되고 있음을 확인할 수 있었다.

  • PDF