• Title/Summary/Keyword: energy minimization

검색결과 385건 처리시간 0.022초

燃燒氣體의 熱力學的 平衡組成計算에 관한 硏究 (Calculation of thermodynamical equilibrium composition of combustion gases)

  • 허병기;이청종
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.177-188
    • /
    • 1987
  • 본 논문에서는 연소기체의 열력학적 평형조성 계산을 위한 수식을 Gibbs의 자 유에너지 최소화법에 의하여 유도하고 이를 컴퓨터 프로그램화하여, Table 1의 특성을 지닌 연료에 대하여 ⅰ) 연소공기량에 따른 평형조성 및 단열불꽃온도, ⅱ) 연소온도 변화에 따른 평형조성의 변화를 계산함으로써 연소기체의 생성기구를 열력학적으로 해 석하였다.

Density Functional Theory (DFT)를 이용한 Tetragonal-Ni1-xPdxSi/Si (001)의 구조 연구 (Structural Study of Tetragonal-Ni1-xPdxSi/Si (001) Using Density Functional Theory (DFT))

  • 김대희;서화일;김영철
    • 한국재료학회지
    • /
    • 제18권9호
    • /
    • pp.482-485
    • /
    • 2008
  • Tetragonal-$Ni_{1-x}Pd_x$Si/Si (001) structure was studied by using density functional theory (DFT). An epitaxial interface between $2{\times}2{\times}4$ (001) tetragonal-NiSi supercell and $1{\times}1{\times}2$ (001) Si supercell was first constructed by adjusting the lattice parameters of B2-NiSi structure to match those of the Si structure. We chose Ni atoms as a terminating layer of the B2-NiSi; the equilibrium gap between the tetragonal-NiSi and Si was calculated to be 1.1 ${\AA}$. The Ni atoms in the structure moved away from the original positions along the z-direction in a systematic way during the energy minimization. Two different Ni sites were identified at the interface and the bulk, respectively. The two Ni sites at the interface have 6 and 7 coordination numbers. The Ni sites with coordination number 6 at the interface were located farther away from the interface, and were more favorable for Pd substitution.

다공 동축 버너를 이용한 순산소 연소 시스템에 관한 연구-PDF 연소 모델을 이용한 수치해석 (A Study on Oxy-Fuel Combustion System with Multi-Jet Burner-Numerical Simulation with PDF Combustion Model)

  • 김현준;최원영;배수호;홍정구;신현동
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.504-512
    • /
    • 2008
  • The characteristics of nonpremixed oxy-fuel flame in a multi-jet burner were experimentally and numerically investigated. The overall flow rate of fuel and oxygen was fixed, and the oxygen feeding ratio (OFR) was varied by 0.25, 0.5, and 0.75. The results of numerical simulation were compared with the measured results which are temperature profile and direct flame observation. The probability density function (PDF) model was applied accounting to the description between turbulence and chemistry, and standard ${\kappa}-{\varepsilon}$ model was used for turbulent flow field. Equilibrium assumption is very reasonable due to fast chemistry of the oxy-fuel combustion. Thus, the equilibrium calculation based on Gibbs free energy minimization was guaranteed to generate the solution of the oxy-fuel combustion. The result was obtained by numerical simulation. The predicted radial temperature profiles were in good agreement with the measured results. The flame length was shorten and was intensified with the decrease of OFR because the mixture of fuel and oxidizer are fast mixed and burnt. The maximum temperature became lower as the OFR increased, as a consequence of large flame surface area.

EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안 (Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation)

  • 성웅;김재원;김태균;이병준;정응수;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

Double Vector Based Model Predictive Torque Control for SPMSM Drives with Improved Steady-State Performance

  • Zhang, Xiaoguang;He, Yikang;Hou, Benshuai
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1398-1408
    • /
    • 2018
  • In order to further improve the steady-state control performance of model predictive torque control (MPTC), a double-vector-based model predictive torque control without a weighting factor is proposed in this paper. The extended voltage vectors synthesized by two basic voltage vectors are used to increase the number of feasible voltage vectors. Therefore, the control precision of the torque and the stator flux along with the steady-state performance can be improved. To avoid testing all of the feasible voltage vectors, the solution of deadbeat torque control is calculated to predict the reference voltage vector. Thus, the candidate voltage vectors, which need to be evaluated by a cost function, can be reduced based on the sector position of the predicted reference voltage vector. Furthermore, a cost function, which only includes a reference voltage tracking error, is designed to eliminate the weighting factor. Moreover, two voltage vectors are applied during one control period, and their durations are calculated based on the principle of reference voltage tracking error minimization. Finally, the proposed method is tested by simulations and experiments.

버스용 병렬형 하이브리드 동력전달계의 개발(III) 제 3 편;최적 주행 제어 알고리즘 (A Development of Parallel Type Hybrid Drivetrain System for Transit Bus Part 3 : Optimal Driving Control Algorithm)

  • 조한상;이장무;박영일
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.182-197
    • /
    • 1999
  • Described in this paper is an optimal driving control algorithm which focused on the improvement of fuel economy and the minimization of pollutant emissions in the parallel type hybrid drivertrain system for transit bus. For the energy balance among components such as engine, induction machine and buttery, the algorithm for power split ration determine is proposed. When it is implemented in the hybrid electric control unit(HECU) , using the sub-optimal method and the approximate technique , it is possible to save the memory , to shorten the calculation time, and to achieve the efficient driving actually. A Shift strategy for automated manual transmission is the other side of the driving control algorithm. It enables to select the optimal gear by using several shift maps which were predefined from the proposed method in this paper, As a results of driving simulation, it is proved that these algorithms make the hybrid drivetrain system to reduce fuel consumption and emissions considerably and to have the ability to the efficient use of battery.

  • PDF

Enhanced Particle Swarm Optimization for Short-Term Non-Convex Economic Scheduling of Hydrothermal Energy Systems

  • Jadoun, Vinay Kumar;Gupta, Nikhil;Niazi, K. R.;Swarnkar, Anil
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.1940-1949
    • /
    • 2015
  • This paper presents an Enhanced Particle Swarm Optimization (EPSO) to solve short-term hydrothermal scheduling (STHS) problem with non-convex fuel cost function and a variety of operational constraints related to hydro and thermal units. The operators of the conventional PSO are dynamically controlled using exponential functions for better exploration and exploitation of the search space. The overall methodology efficiently regulates the velocity of particles during their flight and results in substantial improvement in the conventional PSO. The effectiveness of the proposed method has been tested for STHS of two standard test generating systems while considering several operational constraints like system power balance constraints, power generation limit constraints, reservoir storage volume limit constraints, water discharge rate limit constraints, water dynamic balance constraints, initial and end reservoir storage volume limit constraints, valve-point loading effect, etc. The application results show that the proposed EPSO method is capable to solve the hard combinatorial constraint optimization problems very efficiently.

Large deformation analysis for functionally graded carbon nanotube-reinforced composite plates using an efficient and simple refined theory

  • Bakhti, K.;Kaci, A.;Bousahla, A.A.;Houari, M.S.A.;Tounsi, A.;Adda Bedia, E.A.
    • Steel and Composite Structures
    • /
    • 제14권4호
    • /
    • pp.335-347
    • /
    • 2013
  • In this paper, the nonlinear cylindrical bending behavior of functionally graded nanocomposite plates reinforced by single-walled carbon nanotubes (SWCNTs) is studied using an efficient and simple refined theory. This theory is based on assumption that the in-plane and transverse displacements consist of bending and shear components in which the bending components do not contribute toward shear forces and, likewise, the shear components do not contribute toward bending moments. The material properties of SWCNTs are assumed to be temperature-dependent and are obtained from molecular dynamics simulations. The material properties of functionally graded carbon nanotube-reinforced composites (FG-CNTCRs) are assumed to be graded in the thickness direction, and are estimated through a micromechanical model. The fundamental equations for functionally graded nanocomposite plates are obtained using the Von-Karman theory for large deflections and the solution is obtained by minimization of the total potential energy. The numerical illustrations concern the nonlinear bending response of FG-CNTRC plates under different sets of thermal environmental conditions, from which results for uniformly distributed CNTRC plates are obtained as comparators.

RHC(Routing History Cache)를 사용한 저전력 소모 라우팅 알고리즘 (Low-power Routing Algorithm using Routing History Cache for Wireless Sensor Network)

  • 이두완;장경식
    • 한국정보통신학회논문지
    • /
    • 제13권11호
    • /
    • pp.2441-2446
    • /
    • 2009
  • 무선 센서 네트워크는 특정지역에서 데이터를 수집하여 처리는 작은 센서 노드들로 구성된다. 이러한 센서들은 최초로 설치된 이후에는 배터리로 동작되며, 동작기간이 수개월에서 수년까지 지속되어야 함으로 제한된 자원을 효율적으로 활용할 수 있어야 한다. 본 논문에서는 데이터 중심개념을 적용한 Directed Diffusion의 기본동작구조에 RHC(rounting history cache)를 적용하여, 데이터 전송경로 설정에 신뢰성과 효율성을 높인다. 제안하는 RHC 알고리즘은 각 센서 노드가 자신의 RHC를 주기적으로 업데이트 하여 최적화경로를 저장하고 있기 때문에, 이벤트 발생시마다 경로를 재설정하여 에너지가 낭비되는 것을 최소화하였고, 중복메시지의 최소화로 신뢰성을 향상시켰다.

초고층 공동주택에서 발코니 확장에 따른 창호시스템별 냉방부하 분석 및 비교 (Comparison analysis of cooling loads according to window systems and balcony expansion for a high-rise residential building)

  • 김윤진;박상현;이종찬;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.184-189
    • /
    • 2008
  • These days, Apartment is altered oversized and high-rise through construction techniques development. Also, the cost of cooling and heating load would be expected by balcony expansion into inner space caused by legalization. In specially, HVAC systems of high-rise residential building almost apply to pre-existence techniques of middle and low residential building except for consideration and methods of the air inflow minimization into indoor through mechanical ventilation is used in ventilation system. From these cause, window systems of high-rise apartments stands high in estimation of components. Thus, purpose of this study is to make a comparative study through difference of window systems.

  • PDF